Created
November 30, 2020 17:03
-
-
Save ConorShore/a27c149c49622c7d42c6995d6e5b6cd1 to your computer and use it in GitHub Desktop.
A very simple fan controller to control D51B-2U fans via the IPMI interface
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
#!/bin/bash | |
#Conor Shore 2020 | |
#Basic Fan Control Script For Quanta D51B-2U Server via IPMI | |
#designed to be used in init.d | |
### BEGIN INIT INFO | |
# Provides: IPMI Fan Controller | |
# Required-Start: $all | |
# Required-Stop: | |
# Default-Start: 2 3 4 5 | |
# Default-Stop: 0 1 6 | |
# Short-Description: Controls server fans | |
### END INIT INFO | |
#variable used for temp | |
cputemp=0 | |
#the number the error will be multiplied by | |
factor=5 | |
#target temp | |
target=40 | |
#minimum fan level setting | |
minimum=11 | |
#maximum fan level setting | |
maximum=100 | |
#ip address of the IPMI interface | |
ipmiip="192.168.1.1" | |
# in brackets to run as background tax and not cause timeout | |
(while sleep 15 | |
do | |
#get current temps of each cpu | |
cpu0=$(ipmitool -H $ipmiip -U admin -P admin sensor reading Temp_CPU0 | cut -f2 -d "|" | cut -f2 -d " ") | |
cpu1=$(ipmitool -H $ipmiip -U admin -P admin sensor reading Temp_CPU1 | cut -f2 -d "|" | cut -f2 -d " ") | |
#figure out which cpu is hotter | |
if [ $cpu0 -gt $cpu1 ]; then | |
cputemp=$cpu0 | |
else | |
cputemp=$cpu1 | |
fi | |
error=$((cputemp-target)) | |
#new fan speed | |
newfan=$(((error*factor)+minimum)) | |
#bounding fanspeed to max and min | |
if [ $newfan -lt $minimum ]; then | |
newfan=$minimum | |
fi | |
if [ $newfan -gt $maximum ]; then | |
newfan=$maximum | |
fi | |
#convert to hex | |
newfanhex=$(printf "%x" $newfan) | |
#issue commands | |
ipmitool -H $ipmiip -U admin -P admin raw 0x30 0x39 0x01 0x0 0x0 0x$newfanhex | |
ipmitool -H $ipmiip -U admin -P admin raw 0x30 0x39 0x01 0x0 0x1 0x$newfanhex | |
ipmitool -H $ipmiip -U admin -P admin raw 0x30 0x39 0x01 0x0 0x2 0x$newfanhex | |
ipmitool -H $ipmiip -U admin -P admin raw 0x30 0x39 0x01 0x0 0x3 0x$newfanhex | |
#write to syslog what happened this time around | |
logger "max cpu temp $cputemp setting fans to 0x$newfanhex" | |
done) & | |
exit 0 |