SchwörerHaus WGT BIC VentCube Fresh Home Assistant Integration via modbus
# Helpful information:
# https://github.com/Excodibur/ioBroker.schwoerer-ventcube/blob/master/src/lib/schwoerer/parameters.ts
# https://github.com/fgoettel/wgt/blob/main/wgt/lueftungsanlage.py
# https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/diy-do-it-yourself/1822296-modbus-schwörer-heizung?p=1906252#post1906252
##################
# MODBUS SENSORS #
##################
modbus:
- name: BIC_VentCube
delay: 2
timeout: 3
type: tcp
host: !secret wgt_ip
port: 502
sensors:
- name: VentCube Betriebsart
slave: 1
unique_id: ventcube_betriebsart
address: 100
# Translated with template sensor
# Translated with input_select Automation
- name: VentCube Manuelle Luftstufe
slave: 1
unique_id: ventcube_manuelle_luftstufe
address: 101
# Translated with input_select Automation
- name: VentCube Aktuelle Luftstufe
slave: 1
unique_id: ventcube_aktuelle_luftstufe
address: 102
- name: VentCube Status Stoßlüftung
slave: 1
unique_id: ventcube_status_stosslueftung
address: 111
# Translated with template sensor
- name: VentCube Restlaufzeit Stoßlüftung
slave: 1
unique_id: ventcube_restlaufzeit_stosslueftung
address: 112
unit_of_measurement: min
device_class: duration
min_value: 0
max_value: 60
- name: VentCube Status Wärmepumpe
slave: 1
unique_id: ventcube_status_waermepumpe
address: 114
# Translated with template sensor
- name: VentCube Status Nachheizregister
slave: 1
unique_id: ventcube_status_nachheizregister
address: 116
# Translated with template sensor
- name: VentCube Status Gebläse Zuluft
slave: 1
unique_id: ventcube_status_geblaese_zuluft
address: 117
# Translated with template sensor
- name: VentCube Status Gebläse Abluft
slave: 1
unique_id: ventcube_status_geblaese_abluft
address: 118
# Translated with template sensor
- name: VentCube Bypass Zustand
slave: 1
unique_id: ventcube_bypass_zustand
address: 123
# Translated with template sensor
- name: VentCube Zustand Außenklappe
slave: 1
unique_id: ventcube_zustand_aussenklappe
address: 131
# Translated with template sensor
- name: VentCube Status Vorheizregister
slave: 1
unique_id: ventcube_status_vorheizregister
address: 133
# Translated with template sensor
- name: VentCube aktuelle Luftleistung Zuluft
slave: 1
unique_id: ventcube_aktuelle_luftleistung_zuluft
address: 142
state_class: measurement
unit_of_measurement: "%"
min_value: 0
max_value: 100
scale: 1
precision: 0
- name: VentCube aktuelle Luftleistung Abluft
unique_id: ventcube_aktuelle_luftleistung_abluft
slave: 1
address: 143
state_class: measurement
unit_of_measurement: "%"
min_value: 0
max_value: 100
scale: 1
precision: 0
- name: VentCube aktuelle Drehzahl Zuluft
unique_id: ventcube_aktuelle_drehzahl_zuluft
slave: 1
address: 144
state_class: measurement
unit_of_measurement: "rpm"
min_value: 0
max_value: 10000
precision: 0
- name: VentCube aktuelle Drehzahl Abluft
unique_id: ventcube_aktuelle_drehzahl_abluft
slave: 1
address: 145
state_class: measurement
unit_of_measurement: "rpm"
min_value: 0
max_value: 10000
precision: 0
- name: VentCube T2 Temperatur nach Vorheizregister
slave: 1
unique_id: ventcube_t2_temperatur_nach_vorheizregister
unit_of_measurement: °C
device_class: temperature
address: 201
scale: 0.1
precision: 1
- name: VentCube T3 Temperatur vor Nacherwärmung
slave: 1
unique_id: ventcube_t3_temperatur_vor_nacherwaermung
unit_of_measurement: °C
device_class: temperature
address: 202
scale: 0.1
precision: 1
- name: VentCube T4 Temperatur nach Nacherwärmung
slave: 1
unique_id: ventcube_t4_temperatur_nach_nacherwaermung
unit_of_measurement: °C
device_class: temperature
address: 203
scale: 0.1
precision: 1
- name: VentCube T5 Temperatur Abluft
slave: 1
unique_id: ventcube_t5_temperatur_abluft
unit_of_measurement: °C
device_class: temperature
address: 204
scale: 0.1
precision: 1
- name: VentCube T6 Temperatur im Wärmetauscher
slave: 1
unique_id: ventcube_t6_temperatur_im_waermetauscher
unit_of_measurement: °C
device_class: temperature
address: 205
scale: 0.1
precision: 1
- name: VentCube T10 Temperatur Außen
slave: 1
unique_id: ventcube_t10_temperatur_aussen
unit_of_measurement: °C
device_class: temperature
address: 209
scale: 0.1
precision: 1
- name: VentCube Heiz- Kühlfunktion
slave: 1
unique_id: ventcube_heiz_kuehlfunktion
address: 230
# Translated with template sensor
# Translated with input_select Automation
- name: VentCube Wärmepumpe Heizen
slave: 1
unique_id: ventcube_wp_heizen
address: 231
- name: VentCube Wärmepumpe Kühlen
slave: 1
unique_id: ventcube_wp_kuehlen
address: 232
- name: VentCube Druckwächter aktiv
slave: 1
unique_id: ventcube_druckwachter_aktiv
address: 242
# Translated with template sensor (binary_sensor)
- name: VentCube EVU Sperre aktiv
slave: 1
unique_id: ventcube_evu_sperre_aktiv
address: 243
# Translated with template sensor (binary_sensor)
- name: VentCube Wartungstür offen
slave: 1
unique_id: ventcube_wartungstur_offen
address: 244
# Translated with template sensor (binary_sensor)
- name: VentCube Gerätefilter verschmutzt
slave: 1
unique_id: ventcube_geratefilter_verschmutzt
address: 245
# Translated with template sensor (binary_sensor)
- name: VentCube Vorgelagerter Filter verschmutzt
slave: 1
unique_id: ventcube_vorgelagerter_filter_verschmutzt
address: 246
# Translated with template sensor (binary_sensor)
- name: VentCube Zuluft zu kalt
slave: 1
unique_id: ventcube_zuluft_zu_kalt
address: 254
# Translated with template sensor (binary_sensor)
- name: VentCube Restlaufzeit Gerätefilter
slave: 1
unique_id: ventcube_restlaufzeit_geratefilter
address: 265
unit_of_measurement: d
min_value: 0
max_value: 255
device_class: duration
- name: VentCube Temperatur Wohnzimmer IST
slave: 1
unique_id: ventcube_temperatur_wohnzimmer_ist
unit_of_measurement: °C
device_class: temperature
address: 360
scale: 0.1
precision: 1
min_value: 0
max_value: 100
switches:
- name: VentCube Freigabe WP auf Heizen
slave: 1
address: 231
command_on: 0x1 # Freigabe
command_off: 0x0 # Gesperrt
write_type: holdings
verify:
input_type: holding
state_on: 0x1
state_off: 0x0
delay: 5
unique_id: ventcube_set_waermepumpe_heizen
- name: VentCube Freigabe WP auf Kühlen
slave: 1
address: 232
command_on: 0x1 # Freigabe
command_off: 0x0 # Gesperrt
write_type: holdings
verify:
input_type: holding
state_on: 0x1
state_off: 0x0
delay: 5
unique_id: ventcube_set_waermepumpe_kuehlen
climates:
- name: "VentCube Soll-Temperatur"
unique_id: ventcube_soll_temperatur
slave: 1
address: 400
max_temp: 30
min_temp: 10
offset: 0
precision: 0
scale: 0.1
target_temp_register: 400
target_temp_write_registers: true
temp_step: 1
temperature_unit: °C
- name: "VentCube Basis-Temperatur"
unique_id: ventcube_basis_temperatur
slave: 1
address: 420
max_temp: 30
min_temp: 18
offset: 0
precision: 0
scale: 0.1
target_temp_register: 420
target_temp_write_registers: true
temp_step: 1
temperature_unit: °C
#####################################################
# Select Options which require separate Automations #
#####################################################
input_select:
ventcube_manuelle_luftstufe:
name: VentCube Manuelle Luftstufe
options:
- "0 - Aus"
- "1 - Stufe 1"
- "2 - Stufe 2"
- "3 - Stufe 3"
- "4 - Stufe 4"
- "5 - Automatik"
- "6 - Linearbetrieb"
icon: mdi:fan
ventcube_betriebsart:
name: VentCube Betriebsart
options:
- "0 - Aus"
- "1 - Handbetrieb"
- "2 - Winterbetrieb"
- "3 - Sommerbetrieb"
- "4 - Sommer Abluft"
icon: mdi:fan
ventcube_heiz_kuehlfunktion:
name: VentCube Heiz- Kühlfunktion
options:
- "0 - Aus"
- "1 - Heizen"
- "2 - Kühlen"
- "3 - Auto T-Außen"
- "4 - Auto Digitaler Eingang"
icon: mdi:fan
####################
# TEMPLATE SENSORS #
####################
sensor:
- platform: template
sensors:
ventcube_betriebsart_text:
unique_id: ventcube_betriebsart_text
friendly_name: "VentCube Betriebsart"
value_template: >
{% set mapper = {
'0': 'Aus',
'1': 'Handbetrieb',
'2': 'Winterbetrieb',
'3': 'Sommerbetrieb',
'4': 'Sommer Abluft'} %}
{% set state = states.sensor.ventcube_betriebsart.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_bypass_zustand_text:
unique_id: ventcube_bypass_zustand_text
friendly_name: "VentCube Zustand Bypass"
value_template: >
{% set mapper = {
'0': 'Geschlossen',
'1': 'Offen (Kühlen)',
'2': 'Offen (Heizen)'} %}
{% set state = states.sensor.ventcube_bypass_zustand.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_zustand_aussenklappe_text:
unique_id: ventcube_zustand_aussenklappe_text
friendly_name: "VentCube Zustand Außenklappe"
value_template: >
{% set mapper = {
'0': 'Geschlossen',
'1': 'Offen'} %}
{% set state = states.sensor.ventcube_zustand_aussenklappe.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_status_waermepumpe_text:
unique_id: ventcube_status_waermepumpe_text
friendly_name: "VentCube Status Wärmepumpe"
value_template: >
{% set mapper = {
'0': 'Aus',
'5': 'WP Heizen',
'49': 'WP Kühlen'} %}
{% set state = states.sensor.ventcube_status_waermepumpe.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_heiz_kuehlfunktion_text:
unique_id: ventcube_heiz_kuehlfunktion_text
friendly_name: "VentCube Status Heiz- Kühlfunktion"
value_template: >
{% set mapper = {
'0': 'Aus',
'1': 'Heizen',
'2': 'Kühlen',
'3': 'Auto T-Außen',
'4': 'Auto Digitaler Eingang'} %}
{% set state = states.sensor.ventcube_heiz_kuehlfunktion.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_status_nachheizregister_text:
unique_id: ventcube_status_nachheizregister_text
friendly_name: "VentCube Status Nachheizregister"
value_template: >
{% set mapper = {
'0': 'Inaktiv',
'1': 'Aktiv'} %}
{% set state = states.sensor.ventcube_status_nachheizregister.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_status_vorheizregister_text:
unique_id: ventcube_status_vorheizregister_text
friendly_name: "VentCube Status Vorheizregister"
value_template: >
{% set mapper = {
'0': 'Aus',
'1': 'VHR1 Aktiv',
'2': 'VHR2 Aktiv',
'3': 'VHR1+2 Aktiv'} %}
{% set state = states.sensor.ventcube_status_vorheizregister.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_status_stosslueftung_text:
unique_id: ventcube_status_stosslueftung_text
friendly_name: "VentCube Status Stoßlüftung"
value_template: >
{% set mapper = {
'0': 'Inaktiv',
'1': 'Aktiv'} %}
{% set state = states.sensor.ventcube_status_stosslueftung.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_status_geblaese_zuluft_text:
unique_id: ventcube_status_geblaese_zuluft_text
friendly_name: "VentCube Status Gebläse Zuluft"
value_template: >
{% set mapper = {
'0': 'Deaktiviert',
'1': 'Anlaufphase',
'2': 'Aktiv',
'5': 'Standby',
'6': 'Fehler'} %}
{% set state = states.sensor.ventcube_status_geblaese_zuluft.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
ventcube_status_geblaese_abluft_text:
unique_id: ventcube_status_geblaese_abluft_text
friendly_name: "VentCube Status Gebläse Abluft"
value_template: >
{% set mapper = {
'0': 'Deaktiviert',
'1': 'Anlaufphase',
'2': 'Aktiv',
'5': 'Standby',
'6': 'Fehler'} %}
{% set state = states.sensor.ventcube_status_geblaese_abluft.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
template:
- binary_sensor:
- name: "VentCube Meldung Druckwächter Aktiv"
unique_id: ventcube_meldung_druckwachter_aktiv
device_class: problem
state: >
{% set mapper = {
'0': 'off',
'1': 'on'} %}
{% set state = states.sensor.ventcube_druckwachter_aktiv.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
- name: "VentCube Meldung EVU Sperre aktiv"
unique_id: ventcube_meldung_evu_sperre_aktiv
device_class: problem
state: >
{% set mapper = {
'0': 'off',
'1': 'on'} %}
{% set state = states.sensor.ventcube_evu_sperre_aktiv.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
- name: "VentCube Meldung Wartungstür offen"
unique_id: ventcube_meldung_wartungstur_offen
device_class: problem
state: >
{% set mapper = {
'0': 'off',
'1': 'on'} %}
{% set state = states.sensor.ventcube_wartungstur_offen.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
- name: "VentCube Meldung Gerätefilter verschmutzt"
unique_id: ventcube_meldung_geratefilter_verschmutzt
device_class: problem
state: >
{% set mapper = {
'0': 'off',
'1': 'on'} %}
{% set state = states.sensor.ventcube_geratefilter_verschmutzt.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
- name: "VentCube Meldung Vorgelagerter Filter verschmutzt"
unique_id: ventcube_meldung_vorgelagerter_filter_verschmutzt
device_class: problem
state: >
{% set mapper = {
'0': 'on',
'1': 'off'} %}
{% set state = states.sensor.ventcube_vorgelagerter_filter_verschmutzt.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
- name: "VentCube Meldung Zuluft Zu Kalt"
unique_id: ventcube_meldung_zuluft_zu_kalt
device_class: problem
state: >
{% set mapper = {
'0': 'off',
'1': 'on'} %}
{% set state = states.sensor.ventcube_zuluft_zu_kalt.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
@DaniS81
Copy link

DaniS81 commented May 27, 2025

Hello ;)

für mich ist das mit Modus und Co noch relatives Neuland. Habe jetzt aber im Grunde die Schritte wie beschrieben ausgeführt. Bekomme jedoch bei "Entwicklerwerkzeuge" -> "YAML" bei Konfiguration prüfen folgende Fehlermeldung.

Konfigurationswarnungen
Invalid config for 'modbus' at configuration.yaml, line 12: 'input_select' is an invalid option for 'modbus', check: modbus->0->input_select
Invalid config for 'modbus' at configuration.yaml, line 12: 'modbus' is an invalid option for 'modbus', check: modbus->0->modbus
Invalid config for 'modbus' at configuration.yaml, line 12: 'sensor' is an invalid option for 'modbus', check: modbus->0->sensor
Invalid config for 'modbus' at configuration.yaml, line 12: 'template' is an invalid option for 'modbus', check: modbus->0->template
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'baudrate' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'bytesize' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'method' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'parity' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'port' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'stopbits' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'type' not provided

Hat jemand ne Idee und kann mir hier weiterhelfen? Danke vorab
Grüße
Dani

@NoIdeaForUsernameNow
Copy link

Hallo zusammen,
aktuell läuft bei mir fast alles seht gut, nur leider funktioniert die manuelle Auswahl der Betriebsart & Luftstufe nicht.
Gibt es hier einen separaten Code für für Auswahl Drop-Down-Liste ? Wie muss das konfiguriert werden ?
WGT_manuell

@philipp-bender
Copy link

Hallo zusammen, aktuell läuft bei mir fast alles seht gut, nur leider funktioniert die manuelle Auswahl der Betriebsart & Luftstufe nicht. Gibt es hier einen separaten Code für für Auswahl Drop-Down-Liste ? Wie muss das konfiguriert werden ?

In Home Assistant kannst du nicht direkt in einen modbus sensor schreiben, da sensors grundsätzlich nur lesend arbeiten.
Um einen Wert an ein Modbus-Gerät zu schreiben, musst du stattdessen eine modbus.write_register -Service-Call verwenden – entweder in einer Automation, einem Script oder über eine UI-Button-Action.

Siehe den Kommentar von @ForumSchlampe https://gist.github.com/JavanXD/a3e8911e69f3a27a81eeeb80414bb6ab?permalink_comment_id=5554989#gistcomment-5554989

@Till85apr
Copy link

Till85apr commented Sep 26, 2025

Hi Javan, fettes Dankeschön erstmal für die Mühe hier alles niederzuschreiben.
Ich hab jetzt erstmal deine YAML Codes in meine HA Installation importiert und das meiste funktioniert soweit schon ganz gut.
Ich habe auch dank der verlinkten Dokumentationen zu weiteren Modbus Adressen die Climates für die anderen Räume ergänzen können.

Was bei mir aber nicht funktioniert, ist die Übersetzung mancher Zustände:
{1797DC56-F47C-46C2-BADB-1FE8E3FBFBA4}

Auch der Status der WP (wir haben die WRG134BP/HK, nicht den VentCube) funktioniert auf die gleiche Weise nicht.
Obwohl der numerische Sensorwert korrekt angezeigt wird und die Übersetzungstabelle natürlich diesen Wert übersetzen müsste, ist der Template-Sensor in beiden Fällen dauerhaft auf "UNKNOWN".
wgt_betriebsart_text oder wgt_bypass_zustand_text funktionieren dagegen wie gewollt. Ich verstehe es nicht.
Der Code funktioniert weder 1:1 von dir kopiert, noch wenn ich ihn von einem der funktionierenden Abschnitte kopiere und inhaltlich abändere...

      wgt_status_waermepumpe_text:
        unique_id: wgt_status_waermepumpe_text
        friendly_name: "WGT Status Wärmepumpe"
        value_template: >
          {% set mapper = {
            '0': 'Aus',
            '5': 'WP Heizen',
            '49': 'WP Kühlen'} %}
          {% set state = states.sensor.wgt_status_waermepumpe.state %}
          {{ mapper[state] if state in mapper else 'Unknown' }}

      wgt_heizen_kuehlen_text:
        unique_id: wgt_heizen_kuehlen_text
        friendly_name: "WGT Status Heiz-Kühlfunktion"
        value_template: >
          {% set mapper = {
            '0': 'Aus',
            '1': 'Heizen',
            '2': 'Kühlen',
            '3': 'Auto T-Außen',
            '4': 'Auto Digitaleingang'} %}
          {% set state =  states.sensor.wgt_heiz_kuehlfunktion.state %}
          {{ mapper[state] if state in mapper else 'Unknown' }}

Weißt du woran es liegen könnte?

Und noch eine Frage: Die Climates funktionieren zwar für alle Räume, aber im Dashboard verstehe ich die Thermostat-Anzeige so, dass auf dem Regler die Solltemperatur eingestellt werden soll und darunter klein die IST-Temperatur dargestellt werden soll. Letzteres stimmt aber nicht. Hier wird der Status auf derselben Adresse abgegriffen, also auch die im System hinterlegte Soll-Temperatur. Die IST-Temperaturen müssten anstatt auf den Adressen 400...416 auf den Adressen 360...374 liegen. Aber wie kriege ich diese Werte in die Anzeige?

Beispiel unten: Solltemp ist 21°. Ist-Temp aber 22°C.
{942A2EFF-000F-4BD7-A8C8-E03374278338}

@tobse91
Copy link

tobse91 commented Sep 26, 2025

Bei mir das selbe Problem,

sensor.ventcube_bypass_zustand_text sensor.ventcube_status_geblaese_abluft_text sensor.ventcube_status_geblaese_zuluft_text sensor.ventcube_status_stosslueftung_text sensor.ventcube_status_waermepumpe_text

werden alle als unknown angezeigt.

sensor.ventcube_zustand_aussenklappe_text sensor.ventcube_status_vorheizregister_text sensor.ventcube_status_nachheizregister_text sensor.ventcube_betriebsart_text

Funktionieren hingegen einwandfrei.

Konnte im Code leider auch keinen Fehler entdecken.

@Till85apr
Copy link

Till85apr commented Sep 27, 2025

Und noch eine Frage: Die Climates funktionieren zwar für alle Räume, aber im Dashboard verstehe ich die Thermostat-Anzeige so, dass auf dem Regler die Solltemperatur eingestellt werden soll und darunter klein die IST-Temperatur dargestellt werden soll. Letzteres stimmt aber nicht. Hier wird der Status auf derselben Adresse abgegriffen, also auch die im System hinterlegte Soll-Temperatur. Die IST-Temperaturen müssten anstatt auf den Adressen 400...416 auf den Adressen 360...374 liegen. Aber wie kriege ich diese Werte in die Anzeige?

Beispiel unten: Solltemp ist 21°. Ist-Temp aber 22°C. {942A2EFF-000F-4BD7-A8C8-E03374278338}

Immerhin, dazu hab ich jetzt selbst einen Fix gefunden:
Und zwar ist es falsch für address und target_temp_register dieselbe Addresse zu setzen.
Stattdessen sollte für eine ordnungsgemäße Eintitätsanzeige als Thermostat im Dashboard bei "address" eine aus der Ist-Temperatur Range gewählt werden. Außerdem die Precision auf 1 statt 0.

- name: "Soll-Temperatur Raum 1"
      unique_id: ventcube_soll_temperatur_raum1
      slave: 1
      address: 360
      max_temp: 30
      min_temp: 10
      offset: 0
      precision: 1
      scale: 0.1
      target_temp_register: 400
      target_temp_write_registers: true
      temp_step: 1
      temperature_unit: °C

So sieht das dann aus:
{9F1494D4-AE79-449F-B818-00CD4970C4D0}

@Till85apr
Copy link

Till85apr commented Sep 27, 2025

Bei mir das selbe Problem,

sensor.ventcube_bypass_zustand_text sensor.ventcube_status_geblaese_abluft_text sensor.ventcube_status_geblaese_zuluft_text sensor.ventcube_status_stosslueftung_text sensor.ventcube_status_waermepumpe_text

werden alle als unknown angezeigt.

sensor.ventcube_zustand_aussenklappe_text sensor.ventcube_status_vorheizregister_text sensor.ventcube_status_nachheizregister_text sensor.ventcube_betriebsart_text

Funktionieren hingegen einwandfrei.

Konnte im Code leider auch keinen Fehler entdecken.

Juhuuu! Ich hab es dank Google Gemini geschafft.
Und zwar scheint HA manchmal abweichende Entitäts-IDs zu erstellen. Das muss man über Entwicklerwerkzeuge -> Zustände mit dem Code des Templates abgleichen. Da kommt es scheinbar manchmal zu einem Mismatch und dann fragt der Template Code einen Entitätszustand ab, der nicht existiert.
Konkretes Beispiel bei mir:
a) im YAML Code hinterlegt für den Sensor Heiz-Kühlfunktion ist
unique_id: wgt_heiz_kuehlfunktion

b) im Template wird auf denselben Namen aufgerufen
{%`` set state = states.sensor.wgt_heiz_kuehlfunktion.state %}

Das funktioniert aber nicht, da die Entität anders heißt, nämlich ohne das e:
{AC8294AF-B4A6-4686-AA1C-520B4970B1CF}

Wieso HA das so manchmal macht, ist mir schleierhaft. Vielleicht hat die unique_id aber auch nichts mit dem Entitätsnamen zu tun. Wie der dann generiert wird, ist mir aber auch unklar. Bei Korrektur von b) auf folgendes funktioniert das Template dann aber wie gewollt:
{%`` set state = states.sensor.wgt_heiz_kuhlfunktion.state %}

@AntonWeber93
Copy link

Hallo zusammen, ich bin ziemlich neu in der HA Welt. Wie habt ihr die einzelnen Räume wie Kinderzimmer, Wohnzimmer usw. im HA integriert?

Wäre es generell möglich hier eine Automation o.ä. zu erstellen mit PV?
Es wird geheizt wenn PV den Wert X erreicht und somit die Wärmepumpe mit Zusatzheizung angeht?

@Till85apr
Copy link

Hallo zusammen, ich bin ziemlich neu in der HA Welt. Wie habt ihr die einzelnen Räume wie Kinderzimmer, Wohnzimmer usw. im HA integriert?

Wäre es generell möglich hier eine Automation o.ä. zu erstellen mit PV? Es wird geheizt wenn PV den Wert X erreicht und somit die Wärmepumpe mit Zusatzheizung angeht?

Prinzipiell ist in HA so ziemlich alles möglich sofern man die Werkzeuge dazu hat (Sensordaten und Co). Das heißt du musst das Smart-Meter der PV einbinden und dort die Werte abgreifen. Davon abhängig kannst du dann die Wärmepumpe sowie die ZH im Haus aktivieren lassen und bei Erreichen einer bestimmten Temperatur, oder wenn der HV-Batteriespeicher einen bestimmte Ladezustand unterschreitet, wieder ausschalten.