Setting up Emporia Vue 2 whole-home power monitor with ESPHome
Changelog
- 2022-07-30: add home assistant instructions & MQTT FAQ.
- 2022-07-16: mention using UART adaptor's RTS pin, thanks to @PanicRide
- 2022-07-02: mention mqtt is now supported
- 2022-04-30: bump software version number to 2022.4.0
- 2022-05-04: mention 64-bit ARM issues in FAQ
- USB to serial converter module
- I tested this with a cheap & generic CH340G adapter
- 4 male-to-female jumper wires
- 4 male pcb-mount headers
- Soldering iron & accessories
- esptool.py (windows instructions, generic instructions)
- ESPHome image
You'll want to install the clamps & wiring harness into your panel following the instructions at https://www.emporiaenergy.com/installation-guides. At this time, place a label on each wire using masking tape & a pen rather than connecting them to the energy monitor.
Next, we need to figure out which circuits are on which phases, and in the case of multi-pole breakers, the multiplier. There should be a label like the following on your panel: For each clamp, you want to make a note of the following information:
- clamp number
- circuit number
- phase
- multiplier, if it is a multi-pole breaker
For the wiring harness, you'll want to make a note of which color cable matches which service main clamp (A, B, C).
Here's a starting point for a configuration:
esphome:
name: emporiavue2
external_components:
- source: github://flaviut/[email protected]
components: [ emporia_vue ]
esp32:
board: esp32dev
framework:
type: esp-idf
version: recommended
# Enable Home Assistant API
api: {"password": "<ota password>"}
ota: {"password": "<ota password>"}
# Enable logging
logger:
wifi:
ssid: "<wifi ssid>"
password: "<wifi password>"
i2c:
sda: 21
scl: 22
scan: false
frequency: 200kHz # recommended range is 50-200kHz
id: i2c_a
time:
- platform: sntp
id: my_time
# these are called references in YAML. They allow you to reuse
# this configuration in each sensor, while only defining it once
.defaultfilters:
- &moving_avg
# we capture a new sample every 0.24 seconds, so the time can
# be calculated from the number of samples as n * 0.24.
sliding_window_moving_average:
# we average over the past 2.88 seconds
window_size: 12
# we push a new value every 1.44 seconds
send_every: 6
- &invert
# invert and filter out any values below 0.
lambda: 'return max(-x, 0.0f);'
- &pos
# filter out any values below 0.
lambda: 'return max(x, 0.0f);'
- &abs
# take the absolute value of the value
lambda: 'return abs(x);'
sensor:
- platform: emporia_vue
i2c_id: i2c_a
phases:
- id: phase_a # Verify that this specific phase/leg is connected to correct input wire color on device listed below
input: BLACK # Vue device wire color
calibration: 0.022 # 0.022 is used as the default as starting point but may need adjusted to ensure accuracy
# To calculate new calibration value use the formula <in-use calibration value> * <accurate voltage> / <reporting voltage>
voltage:
name: "Phase A Voltage"
filters: [*moving_avg, *pos]
- id: phase_b # Verify that this specific phase/leg is connected to correct input wire color on device listed below
input: RED # Vue device wire color
calibration: 0.022 # 0.022 is used as the default as starting point but may need adjusted to ensure accuracy
# To calculate new calibration value use the formula <in-use calibration value> * <accurate voltage> / <reporting voltage>
voltage:
name: "Phase B Voltage"
filters: [*moving_avg, *pos]
ct_clamps:
- phase_id: phase_a
input: "A" # Verify the CT going to this device input also matches the phase/leg
power:
name: "Phase A Power"
id: phase_a_power
device_class: power
filters: [*moving_avg, *pos]
- phase_id: phase_b
input: "B" # Verify the CT going to this device input also matches the phase/leg
power:
name: "Phase B Power"
id: phase_b_power
device_class: power
filters: [*moving_avg, *pos]
# Pay close attention to set the phase_id for each breaker by matching it to the phase/leg it connects to in the panel
- { phase_id: phase_a, input: "1", power: { name: "Circuit 1 Power", id: cir1, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "2", power: { name: "Circuit 2 Power", id: cir2, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_a, input: "3", power: { name: "Circuit 3 Power", id: cir3, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_a, input: "4", power: { name: "Circuit 4 Power", id: cir4, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_a, input: "5", power: { name: "Circuit 5 Power", id: cir5, filters: [ *moving_avg, *pos, multiply: 2 ] } }
- { phase_id: phase_a, input: "6", power: { name: "Circuit 6 Power", id: cir6, filters: [ *moving_avg, *pos, multiply: 2 ] } }
- { phase_id: phase_a, input: "7", power: { name: "Circuit 7 Power", id: cir7, filters: [ *moving_avg, *pos, multiply: 2 ] } }
- { phase_id: phase_b, input: "8", power: { name: "Circuit 8 Power", id: cir8, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "9", power: { name: "Circuit 9 Power", id: cir9, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "10", power: { name: "Circuit 10 Power", id: cir10, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_a, input: "11", power: { name: "Circuit 11 Power", id: cir11, filters: [ *moving_avg, *pos, multiply: 2 ] } }
- { phase_id: phase_a, input: "12", power: { name: "Circuit 12 Power", id: cir12, filters: [ *moving_avg, *pos, multiply: 2 ] } }
- { phase_id: phase_a, input: "13", power: { name: "Circuit 13 Power", id: cir13, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_a, input: "14", power: { name: "Circuit 14 Power", id: cir14, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_b, input: "15", power: { name: "Circuit 15 Power", id: cir15, filters: [ *moving_avg, *pos ] } }
- { phase_id: phase_a, input: "16", power: { name: "Circuit 16 Power", id: cir16, filters: [ *moving_avg, *pos ] } }
- platform: template
name: "Total Power"
lambda: return id(phase_a_power).state + id(phase_b_power).state;
update_interval: 1s
id: total_power
unit_of_measurement: "W"
- platform: total_daily_energy
name: "Total Daily Energy"
power_id: total_power
accuracy_decimals: 0
- { power_id: cir1, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 1 Daily Energy" }
- { power_id: cir2, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 2 Daily Energy" }
- { power_id: cir3, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 3 Daily Energy" }
- { power_id: cir4, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 4 Daily Energy" }
- { power_id: cir5, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 5 Daily Energy" }
- { power_id: cir6, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 6 Daily Energy" }
- { power_id: cir7, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 7 Daily Energy" }
- { power_id: cir8, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 8 Daily Energy" }
- { power_id: cir9, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 9 Daily Energy" }
- { power_id: cir10, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 10 Daily Energy" }
- { power_id: cir11, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 11 Daily Energy" }
- { power_id: cir12, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 12 Daily Energy" }
- { power_id: cir13, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 13 Daily Energy" }
- { power_id: cir14, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 14 Daily Energy" }
- { power_id: cir15, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 15 Daily Energy" }
- { power_id: cir16, platform: total_daily_energy, accuracy_decimals: 0, name: "Circuit 16 Daily Energy" }
You'll want to replace <ota password>
, <wifi ssid>
, and <wifi password>
with a unique password, and your wifi credentials, respectively.
You'll also want to update the sensor
section of the configuration using the information you've collected in Panel installation, part 1.
Note the sliding_window_moving_average
. This is optional, but since we get a reading every 240ms, it is helpful to average these readings together so that we don't need to store such dense, noisy, data in Home Assistant.
Note the "Total Power", "Total Daily Energy", and "Circuit x Daily Energy". This is needed for the Home Assistant energy system, which requires daily kWh numbers.
Do not use the web_server
since it is not compatible with the esp-idf
framework, and you will get odd error messages.
It's not too critical to get this right on the first try, because you can update the board over WiFi using the ESPHome Dashboard.
Pry the lever on one of the jumper cables up using a pencil or a needle or some other sharp thing. If your cables don't have a lever, cut one end of the cable & strip it using scissors or a knife. You will then need to solder a serial header onto the programming port, so that it looks like this:
Plug the USB adapter in. Connect RX to RX, TX to TX, and GND to GND. Do not connect 5V or 3.3V at this time.
Plug in the unmodified end of the cable we modified above into the IO0 pin of the Emporia Vue 2.
Open a console window and test that esptool.py version
works.
Hold the modified end of the cable in IO0 to the metal shield on the ESP32. If you'd like, you can tape it down so that you have both hands free.
While holding it in place, connect 5V on your UART adapter to the VCC_5V0
pin on the board.
If your TTL adapter has both the DTR and RTS pins exposed, you can let it automatically reboot the board and put the chip into flash mode when necessary. IO0 connects to DTR, and EN connects to RTS. In this case, you don't need to hold anything down.
With your other hand, run the following in the console: esptool.py -b 921600 read_flash 0 0x800000 flash_contents.bin
. Successful completion of this step is critical in case something goes wrong later. This file is necessary to restore the device to factory function.
If the above command fails, try again using esptool.py -b 115200 read_flash 0 0x800000 flash_contents.bin
.
With your other hand, run the following in the console: esphome run vue2.yaml
. This will take a few minutes, and install the new software on the Vue 2!
You'll see a bunch of errors like Failed to read from sensor due to I2C error 3
, but that's fine, since they'll go away when it is installed into into the wall.
Reassemble to Vue 2, and follow the instructions to plug everything in & started up!
This project works best with Home Assistant. Follow these instructions to connect the Vue 2 to Home Assistant.
Once you connect the Vue to Home Assistant, you can configure the Home Assistant energy monitor functionallity, as well as a variety of automations.
MQTT is an alternative way of communicating the readings. If you need it, you already know, and it is not required for use with Home Assistant.
There's now support for MQTT with this integration thanks to the hard work of the ESPHome folks! Please reference MQTT Client Component for how to get this set up.
- You may have put that clamp on the wire backwards
- You may have selected the wrong phase in the configuration
Sometimes the CTs aren't fully plugged into the 3.5mm jacks on the Vue. It's often not an issue with the initial install, but with stuff getting jostled around as you put things back together.
This issue will often manifest as jumps between 0W and some other wattage for no reason.
Open up the panel, and make sure every connector is fully inserted into the Vue. Check if the problem is solved before putting the panel cover back on.
If your readings are within ±1W, then they're within the expected margin of error. The filters are designed to smooth out noise like this, and it's expected as no physical system can be perfect.
If the readings are significant outside of that, there may be a problem.
First off, you will want to remove all filters for that sensor. Replace filters: [ *moving_avg, *pos ]
, etc, with filters: []
.
If your data is hovering around 0, then you either don't have any load on that circuit or there's some other issue that hasn't come up before.
If you're seeing negative data, it could be a few things:
- First off, make sure you've properly installed the clamps according to the instructions. The L side of the clamp should point towards the load. For solar systems or similar, keep in mind that current flows from the solar panel to your electrical panel, not the other way.
- Make sure you've selected the correct phase in the configuration. You will get negative and nonsense power readings if you select the wrong phase. You can't negate the data through a filter and expect it to be correct.
When you're done troubleshooting, remember to place the filters back.
If you're using a 64-bit ARM OS, unfortunately you are unable to build this. It's not a limitation with this project, but a limitation with the upstream PlatformIO toolchains.
You'll see an error like
Could not find the package with 'platformio/toolchain-esp32ulp @ ~1.22851.0' requirements for your system 'linux_aarch64'
You can try using a different computer. 32-bit and 64-bit x86 computers are both compatible (most laptops & desktops).
(c) 2021 Flaviu Tamas
Licensed under CC-BY-4.0