Save LongLiveCHIEF/829f0924087fac0afcb70d039f048fca to your computer and use it in GitHub Desktop.
ESPHome sample configuration for an HX711 powered Smart Scale including Auto-Tare functionality.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
## Node configuration ## | |
esphome: | |
name: smart_scale | |
platform: ESP8266 | |
board: nodemcuv2 | |
globals: | |
- id: initial_zero | |
type: float | |
restore_value: yes | |
# NOTE: make sure to align this value to the one used in "calibrate_linear" below! | |
initial_value: '-481989' | |
- id: auto_tare_enabled | |
type: bool | |
restore_value: yes | |
initial_value: 'true' | |
- id: auto_tare_difference | |
type: float | |
restore_value: yes | |
initial_value: '0' | |
- id: manual_tare_flag | |
type: bool | |
restore_value: no | |
initial_value: 'false' | |
wifi: | |
fast_connect: True # needed for hidden SSID | |
networks: | |
- ssid: 'YourSSID' | |
bssid: '00:00:00:00:00:00' | |
password: 'YourPassword' | |
hidden: true | |
#manual_ip: | |
# static_ip: 192.168.5.49 | |
# gateway: 192.168.5.1 | |
# subnet: 255.255.255.0 | |
api: | |
password: "YourApiPassword" | |
# Enable logging | |
logger: | |
level: ERROR | |
ota: | |
password: 'YourOtaPassword' | |
status_led: | |
pin: | |
number: GPIO2 | |
inverted: True | |
switch: | |
## Switch to enable/disable the auto tare feature | |
- platform: template | |
id: smart_scale_continuous_tare_enabled | |
name: "Smart Scale Continuous Tare Enabled" | |
lambda: |- | |
return id(auto_tare_enabled); | |
turn_on_action: | |
- lambda: |- | |
id(auto_tare_enabled) = true; | |
turn_off_action: | |
- lambda: |- | |
id(auto_tare_enabled) = false; | |
## Switch used to initiate a manual tare | |
- platform: template | |
id: smart_scale_manual_tare_action_switch | |
name: "Smart Scale Manual Tare Action" | |
lambda: |- | |
return id(manual_tare_flag); | |
turn_on_action: | |
- lambda: |- | |
id(auto_tare_difference) = id(initial_zero) - id(smart_scale_hx711_value_raw).state; | |
- switch.turn_off: smart_scale_manual_tare_action_switch | |
turn_off_action: | |
- lambda: |- | |
id(manual_tare_flag) = false; | |
## Sensor Configuration ## | |
sensor: | |
# template sensors from global variables | |
- platform: template | |
id: smart_scale_initial_zero | |
name: "Smart Scale Initial Zero" | |
lambda: |- | |
return id(initial_zero); | |
update_interval: 1s | |
- platform: template | |
id: smart_scale_auto_tare_difference | |
name: "Smart Scale Auto Tare Difference" | |
lambda: |- | |
return id(auto_tare_difference); | |
update_interval: 1s | |
# sensors imported from home assistant | |
- platform: homeassistant | |
id: homeassistant_initial_zero | |
entity_id: input_number.smart_scale_initial_zero | |
on_value: | |
then: | |
- lambda: |- | |
id(initial_zero) = x; | |
# RAW Scale input | |
- platform: hx711 | |
id: smart_scale_hx711_value_raw | |
internal: True | |
dout_pin: D0 | |
clk_pin: D1 | |
gain: 128 | |
unit_of_measurement: kg | |
accuracy_decimals: 3 | |
update_interval: 0.2s | |
filters: | |
- sliding_window_moving_average: | |
window_size: 3 | |
send_every: 1 | |
on_value: | |
then: | |
- sensor.template.publish: | |
id: smart_scale_hx711_value | |
state: !lambda 'return id(smart_scale_hx711_value_raw).state;' | |
- if: | |
condition: | |
and: | |
- lambda: 'return id(auto_tare_enabled);' | |
# current smart scale value is below approx. 10KG (raw value -275743) aka nobody is standing on the scale | |
- lambda: 'return id(smart_scale_hx711_value).state < 10.0;' | |
then: | |
- if: | |
condition: | |
# current raw scale value is below expected zero value | |
- lambda: 'return id(smart_scale_hx711_value_raw).state < (id(initial_zero) - id(auto_tare_difference));' | |
then: | |
# INcrease Auto-Tare offset to slowly align real zero value with expected zero value | |
- lambda: |- | |
id(auto_tare_difference) += 10; | |
else: | |
# DEcrease Auto-Tare offset to slowly align real zero value with expected zero value | |
- lambda: |- | |
id(auto_tare_difference) -= 10; | |
# Mapped value to KG | |
- platform: template | |
id: smart_scale_hx711_value | |
name: "Smart Scale HX711 Value" | |
internal: False | |
filters: | |
# apply auto_tare difference | |
- lambda: 'return x + id(auto_tare_difference);' | |
# apply rough calibration | |
- calibrate_linear: | |
# retrieve these values by evaluating the raw values with loads of known mass. | |
# note that a bigger difference between measurements usually results in higher resolution, | |
# so measure 0 Kg and the highest known mass you have (like f.ex. your own weight, measured by a normal scale with good accuracy) | |
- -481989 -> 0 | |
- 1339163 -> 88.3 | |
# map values below 0.1 to 0 (to decrease value changes due to random fluctuation) | |
- lambda: |- | |
if (x <= 0.1) { | |
return 0.0; | |
} else { | |
return x; | |
} | |
unit_of_measurement: kg | |
accuracy_decimals: 2 | |
update_interval: 0.2s |