Passage RAID 0 en RAID 1 OMSA CLI
##################################
Finding the controller number & ID:
------------------------------------
[root@server ~]# omreport storage controller |grep -A3 "^ID"
ID : 0
Status : Ok
Name : PERC H310 Mini
Slot ID : Embedded
--
ID : 1
Status : Ok
Name : PERC H810 Adapter
Slot ID : PCI Slot 1
Finding the physical Hdd’s number & ID:
---------------------------------------
[root@server ~]# omreport storage pdisk controller=1 |grep -Ew "^ID"
ID : 0:0:0
ID : 0:0:1
ID : 0:0:2
ID : 0:0:3
Checking (and correcting) the Hdd’s state:
------------------------------------------
[root@server ~]# omreport storage pdisk controller=1 |grep "^State"
State : Foreign
State : Foreign
Correcting the Hdd state:
-------------------------
[root@server ~]# omconfig storage controller controller=1 action=clearforeignconfig
Command successful!
Création du raid:
-----------------
omconfig storage vdisk action=reconfigure controller=0 vdisk=0 raid=r1 pdisk=0:0:1,0:0:0
0:0:1= disk primaire
0:0:0= disk secondaire