Save MexsonFernandes/37d56c2d3a0adaf7d54f7d3faa5b0c80 to your computer and use it in GitHub Desktop.
%clear everything before loading | |
clc; | |
clear ALL; | |
pause on; | |
%loading dll library, header file and other libraries | |
%(libfunctionsview thinkgear to view dll) | |
if ~libisloaded('Thinkgear') | |
loadlibrary('Thinkgear.dll'); | |
else | |
unloadlibrary Thinkgear | |
loadlibrary('Thinkgear.dll'); | |
end | |
disp('libraries loaded successfully.') | |
path = 'E:/StartInnovating/Projects/1_Neurosky_robot_control_EEG/Matlab_Code/'; | |
%to compute data of 14 columns | |
data = ones(61440,14); | |
portnum1 = 7; %COM Port # | |
comPortName1 = sprintf('\\\\.\\COM%d', portnum1); | |
% Baud rate for use with TG_Connect() and TG_SetBaudrate(). | |
TG_BAUD_115200 = 115200; | |
% Data format for use with TG_Connect() and TG_SetDataFormat(). | |
TG_STREAM_PACKETS = 0; | |
% Data type that can be requested from TG_GetValue(). | |
TG_DATA_POOR_SIGNAL = 1; | |
TG_DATA_ATTENTION = 2; | |
TG_DATA_MEDITATION = 3; | |
TG_DATA_RAW = 4; | |
TG_DATA_DELTA = 5; | |
TG_DATA_THETA = 6; | |
TG_DATA_ALPHA1 = 7; | |
TG_DATA_ALPHA2 = 8; | |
TG_DATA_BETA1 = 9; | |
TG_DATA_BETA2 = 10; | |
TG_DATA_GAMMA1 = 11; | |
TG_DATA_GAMMA2 = 12; | |
TG_DATA_BLINK_STRENGTH = 37; | |
% Get a connection ID handle to ThinkGear | |
connectionId1 = calllib('Thinkgear', 'TG_GetNewConnectionId'); | |
if ( connectionId1 < 0 ) | |
calllib('Thinkgear', 'TG_FreeConnection', connectionId1 ); | |
error(sprintf( 'ERROR: TG_GetNewConnectionId() returned %d.\n' , connectionId1 )); | |
end | |
% Attempt to connect the connection ID handle to serial port "COM8" | |
errCode = calllib('Thinkgear', 'TG_Connect', connectionId1,comPortName1,TG_BAUD_115200,TG_STREAM_PACKETS ); | |
if ( errCode < 0 ) | |
calllib('Thinkgear', 'TG_FreeConnection', connectionId1 ); | |
error(sprintf('ERROR: TG_Connect() returned %d.\n' , errCode) ); | |
end | |
%recording data | |
fprintf( 'Connected. Reading Packets...\n' ); | |
for i=1:120 %loop for 120 seconds | |
if (calllib('Thinkgear','TG_ReadPackets',connectionId1,1) == 1) %if a packet was read... | |
for j=1:14 | |
if(j == 1) | |
data(i,j) = now; | |
end | |
if(j == 2) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_POOR_SIGNAL) ~= 0) %if RAW has been updated | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_POOR_SIGNAL); | |
end | |
end | |
if(j == 3) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_ATTENTION) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_ATTENTION); | |
end | |
end | |
if(j == 4) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_MEDITATION) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_MEDITATION); | |
end | |
end | |
if(j == 5) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_RAW) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_RAW); | |
end | |
end | |
if(j == 6) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_DELTA) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_DELTA); | |
end | |
end | |
if(j == 7) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_THETA) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_THETA); | |
end | |
end | |
if(j == 8) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_ALPHA1) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_ALPHA1); | |
end | |
end | |
if(j == 9) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_ALPHA2) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_ALPHA2); | |
end | |
end | |
if(j == 10) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_BETA1) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_BETA1); | |
end | |
end | |
if(j == 11) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_BETA2) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_BETA2); | |
end | |
end | |
if(j == 12) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_GAMMA1) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_GAMMA1); | |
end | |
end | |
if(j == 13) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_GAMMA2) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_GAMMA2); | |
end | |
end | |
if(j == 14) | |
if (calllib('Thinkgear','TG_GetValueStatus',connectionId1,TG_DATA_BLINK_STRENGTH) ~= 0) | |
data(i,j) = calllib('Thinkgear','TG_GetValue',connectionId1,TG_DATA_BLINK_STRENGTH); | |
end | |
end | |
end | |
end | |
pause(1) | |
end | |
fprintf( 'Completed reading data.\n' ); | |
%save data to csv file | |
csvwrite(path + 'data.csv',data); | |
dlmwrite(path + 'data.csv',data,'precision', '%.6f'); | |
% disconnect | |
calllib('Thinkgear', 'TG_FreeConnection', connectionId1 ); | |
Where exactly we can find that dll file ?
You can use the above link to download the DLL files. I am sure you will find the same one from developer documentation of Neurosky.
hello sir i need to ask about this path line
on line 15 if i paste this code on matlab what path i need to write there ?
i am making wheelchair using mindwave mobile and i need blink strength data
you can write any location there. The processed data will be saved in this path.
@MexsonFernandes, Perfect! thanks for the file and details. Works fine now.
I have one last query. Does this code work for "Neurosky mind wave mobile 2" headsets?
Because I am getting all empty data.
It does for Neurosky Mind Wave Mobile 2 headset. You can refer below repository. Although it's not well documented, you can still refer to some code.
https://github.com/MexsonFernandes/EEG-controlled-Robot-using-Neurosky-Mindwave-Mobile2
@MexsonFernandes, Perfect! thanks for the file and details. Works fine now.
I have one last query. Does this code work for "Neurosky mind wave mobile 2" headsets?
Because I am getting all empty data.
https://gist.github.com/MexsonFernandes/c08ad378e7cad5c98b5c2dc912797dc1 Refer this gist as well.
Good night, I need some help with code, please, if you can tell me how I can to increase of data number for second that the code can to capture.
hello sir
I faced a problem every time run project it is ...
Error using eeg (line 54)
ERROR: TG_Connect() returned -2.
can you help me, please?
You can use the above link to download the DLL files. I am sure you will find the same one from developer documentation of Neurosky.
sorry , can you please send this link again? ...it isn't available.
@urmi2927 your only problem is that your are using wrong library. Use the correct one and it will work
hello sir i need to ask about this path line
on line 15 if i paste this code on matlab what path i need to write there ?
i am making wheelchair using mindwave mobile and i need blink strength data