/* Ex1_Combined_Basic_Example_ENS160_BME280.ino | |
This example shows basic data retrieval from the SparkFun Environmental Combo Breakout | |
from the Air Quality Sensor (ENS160) and Atmospheric Sensor (BME280). | |
This example shows how to read sensor readings from the ENS160 (air quality index tVOC, and eCO2) | |
and BME280 (humidity, pressure, and current temperature) over I2C. | |
Modified by: | |
Ho Yun "Bobby" Chan @ SparkFun Electronics August, 2023 | |
Basic Example for the ENS160 Originally Written by: | |
Elias Santistevan @ SparkFun Electronics October, 2022 | |
Basic Example for the ENS160 Originally Written by: | |
Nathan Seidle @ SparkFun Electronics March 9th, 2018 | |
Products: | |
Air Quality Sensor (ENS160) - https://www.sparkfun.com/products/20844 | |
Humidity and Temperature Sensor (BME280) - https://www.sparkfun.com/products/13676 | |
Repository: | |
https://github.com/sparkfun/SparkFun_Indoor_Air_Quality_Sensor-ENS160_Arduino_Library | |
SparkFun code, firmware, and software is released under the MIT | |
License(http://opensource.org/licenses/MIT). | |
*/ | |
#include <Wire.h> | |
#include "SparkFun_ENS160.h" // Click here to get the library: http://librarymanager/All#SparkFun_ENS160 | |
#include "SparkFunBME280.h" // Click here to get the library: http://librarymanager/All#SparkFun_BME280 | |
SparkFun_ENS160 myENS; | |
BME280 myBME280; | |
int ensStatus; | |
void setup() { | |
Wire.begin(); | |
Serial.begin(115200); | |
if (!myENS.begin()) { | |
Serial.println("Did not begin."); | |
while (1) | |
; | |
} | |
if (myBME280.beginI2C() == false) //Begin communication over I2C | |
{ | |
Serial.println("The sensor did not respond. Please check wiring."); | |
while (1) | |
; //Freeze | |
} | |
// Reset the indoor air quality sensor's settings. | |
if (myENS.setOperatingMode(SFE_ENS160_RESET)) | |
Serial.println("Ready."); | |
delay(100); | |
// Device needs to be set to idle to apply any settings. | |
// myENS.setOperatingMode(SFE_ENS160_IDLE); | |
// Set to standard operation | |
// Others include SFE_ENS160_DEEP_SLEEP and SFE_ENS160_IDLE | |
myENS.setOperatingMode(SFE_ENS160_STANDARD); | |
// There are four values here: | |
// 0 - Operating ok: Standard Operation | |
// 1 - Warm-up: occurs for 3 minutes after power-on. | |
// 2 - Initial Start-up: Occurs for the first hour of operation. | |
// and only once in sensor's lifetime. | |
// 3 - No Valid Output | |
ensStatus = myENS.getFlags(); | |
Serial.print("Gas Sensor Status Flag: "); | |
Serial.println(ensStatus); | |
} | |
void loop() { | |
if (myENS.checkDataStatus()) { | |
Serial.print("Air Quality Index (1-5) : "); | |
Serial.println(myENS.getAQI()); | |
Serial.print("Total Volatile Organic Compounds: "); | |
Serial.print(myENS.getTVOC()); | |
Serial.println("ppb"); | |
Serial.print("CO2 concentration: "); | |
Serial.print(myENS.getECO2()); | |
Serial.println("ppm"); | |
Serial.print("Humidity: "); | |
Serial.print(myBME280.readFloatHumidity(), 0); | |
Serial.println("RH%"); | |
Serial.print("Pressure: "); | |
Serial.print(myBME280.readFloatPressure(), 0); | |
Serial.println("Pa"); | |
Serial.print("Alt: "); | |
//Serial.print(myBME280.readFloatAltitudeMeters(), 1); | |
//Serial.println("meters"); | |
Serial.print(myBME280.readFloatAltitudeFeet(), 1); | |
Serial.println("feet"); | |
Serial.print("Temp: "); | |
//Serial.print(myBME280.readTempC(), 2); | |
//Serial.println(" degC"); | |
Serial.print(myBME280.readTempF(), 2); | |
Serial.println(" degF"); | |
Serial.println(); | |
} | |
delay(200); | |
} |