[nixos@nixos:~]$ sudo smartctl -a /dev/sdb | |
smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.10.62] (local build) | |
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org | |
=== START OF INFORMATION SECTION === | |
Model Family: Toshiba 3.5" DT01ACA... Desktop HDD | |
Device Model: TOSHIBA DT01ACA200 | |
Serial Number: 84QBH18TS | |
LU WWN Device Id: 5 000039 ffad3500c | |
Firmware Version: MX4OABB0 | |
User Capacity: 2,000,398,934,016 bytes [2.00 TB] | |
Sector Sizes: 512 bytes logical, 4096 bytes physical | |
Rotation Rate: 7200 rpm | |
Form Factor: 3.5 inches | |
Device is: In smartctl database [for details use: -P show] | |
ATA Version is: ATA8-ACS T13/1699-D revision 4 | |
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s) | |
Local Time is: Sun Jan 23 12:29:49 2022 UTC | |
SMART support is: Available - device has SMART capability. | |
SMART support is: Enabled | |
=== START OF READ SMART DATA SECTION === | |
SMART overall-health self-assessment test result: FAILED! | |
Drive failure expected in less than 24 hours. SAVE ALL DATA. | |
See vendor-specific Attribute list for failed Attributes. | |
General SMART Values: | |
Offline data collection status: (0x84) Offline data collection activity | |
was suspended by an interrupting command from host. | |
Auto Offline Data Collection: Enabled. | |
Self-test execution status: ( 0) The previous self-test routine completed | |
without error or no self-test has ever | |
been run. | |
Total time to complete Offline | |
data collection: (14822) seconds. | |
Offline data collection | |
capabilities: (0x5b) SMART execute Offline immediate. | |
Auto Offline data collection on/off support. | |
Suspend Offline collection upon new | |
command. | |
Offline surface scan supported. | |
Self-test supported. | |
No Conveyance Self-test supported. | |
Selective Self-test supported. | |
SMART capabilities: (0x0003) Saves SMART data before entering | |
power-saving mode. | |
Supports SMART auto save timer. | |
Error logging capability: (0x01) Error logging supported. | |
General Purpose Logging supported. | |
Short self-test routine | |
recommended polling time: ( 1) minutes. | |
Extended self-test routine | |
recommended polling time: ( 247) minutes. | |
SCT capabilities: (0x003d) SCT Status supported. | |
SCT Error Recovery Control supported. | |
SCT Feature Control supported. | |
SCT Data Table supported. | |
SMART Attributes Data Structure revision number: 16 | |
Vendor Specific SMART Attributes with Thresholds: | |
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE | |
1 Raw_Read_Error_Rate 0x000b 067 067 016 Pre-fail Always - 6282 | |
2 Throughput_Performance 0x0005 062 062 054 Pre-fail Offline - 2103 | |
3 Spin_Up_Time 0x0007 126 126 024 Pre-fail Always - 311 (Average 290) | |
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 1089 | |
5 Reallocated_Sector_Ct 0x0033 001 001 005 Pre-fail Always FAILING_NOW 943 | |
7 Seek_Error_Rate 0x000b 064 064 067 Pre-fail Always FAILING_NOW 327873 | |
8 Seek_Time_Performance 0x0005 001 001 020 Pre-fail Offline FAILING_NOW 2190 | |
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 6540 | |
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 | |
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 731 | |
192 Power-Off_Retract_Count 0x0032 097 097 000 Old_age Always - 4628 | |
193 Load_Cycle_Count 0x0012 097 097 000 Old_age Always - 4628 | |
194 Temperature_Celsius 0x0002 240 240 000 Old_age Always - 25 (Min/Max 14/44) | |
196 Reallocated_Event_Count 0x0032 001 001 000 Old_age Always - 17257 | |
197 Current_Pending_Sector 0x0022 001 001 000 Old_age Always - 8784 | |
198 Offline_Uncorrectable 0x0008 097 097 000 Old_age Offline - 227 | |
199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 19 | |
SMART Error Log Version: 1 | |
ATA Error Count: 23288 (device log contains only the most recent five errors) | |
CR = Command Register [HEX] | |
FR = Features Register [HEX] | |
SC = Sector Count Register [HEX] | |
SN = Sector Number Register [HEX] | |
CL = Cylinder Low Register [HEX] | |
CH = Cylinder High Register [HEX] | |
DH = Device/Head Register [HEX] | |
DC = Device Command Register [HEX] | |
ER = Error register [HEX] | |
ST = Status register [HEX] | |
Powered_Up_Time is measured from power on, and printed as | |
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, | |
SS=sec, and sss=millisec. It "wraps" after 49.710 days. | |
Error 23288 occurred at disk power-on lifetime: 6540 hours (272 days + 12 hours) | |
When the command that caused the error occurred, the device was active or idle. | |
After command completion occurred, registers were: | |
ER ST SC SN CL CH DH | |
-- -- -- -- -- -- -- | |
40 51 08 08 08 00 00 Error: UNC at LBA = 0x00000808 = 2056 | |
Commands leading to the command that caused the error were: | |
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name | |
-- -- -- -- -- -- -- -- ---------------- -------------------- | |
60 08 f8 00 0a 80 40 08 00:00:54.319 READ FPDMA QUEUED | |
60 08 b8 80 08 c0 40 08 00:00:54.318 READ FPDMA QUEUED | |
60 08 b0 00 09 80 40 08 00:00:54.318 READ FPDMA QUEUED | |
60 08 a8 40 08 c0 40 08 00:00:54.318 READ FPDMA QUEUED | |
60 08 a0 80 08 80 40 08 00:00:54.310 READ FPDMA QUEUED | |
Error 23287 occurred at disk power-on lifetime: 6540 hours (272 days + 12 hours) | |
When the command that caused the error occurred, the device was active or idle. | |
After command completion occurred, registers were: | |
ER ST SC SN CL CH DH | |
-- -- -- -- -- -- -- | |
40 51 08 08 08 00 00 Error: UNC at LBA = 0x00000808 = 2056 | |
Commands leading to the command that caused the error were: | |
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name | |
-- -- -- -- -- -- -- -- ---------------- -------------------- | |
60 08 90 20 08 c0 40 08 00:00:50.385 READ FPDMA QUEUED | |
60 08 88 20 08 80 40 08 00:00:50.385 READ FPDMA QUEUED | |
60 08 80 08 08 00 40 08 00:00:50.384 READ FPDMA QUEUED | |
60 08 78 f8 06 80 40 08 00:00:50.384 READ FPDMA QUEUED | |
60 08 70 a8 87 e0 40 08 00:00:50.384 READ FPDMA QUEUED | |
Error 23286 occurred at disk power-on lifetime: 6540 hours (272 days + 12 hours) | |
When the command that caused the error occurred, the device was active or idle. | |
After command completion occurred, registers were: | |
ER ST SC SN CL CH DH | |
-- -- -- -- -- -- -- | |
40 51 f8 08 08 00 00 Error: UNC at LBA = 0x00000808 = 2056 | |
Commands leading to the command that caused the error were: | |
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name | |
-- -- -- -- -- -- -- -- ---------------- -------------------- | |
60 00 b0 00 08 80 40 08 00:00:36.327 READ FPDMA QUEUED | |
60 00 a8 00 08 c0 40 08 00:00:36.327 READ FPDMA QUEUED | |
60 00 a0 00 08 00 40 08 00:00:36.327 READ FPDMA QUEUED | |
60 00 98 00 00 00 40 08 00:00:36.327 READ FPDMA QUEUED | |
60 08 10 00 00 00 40 08 00:00:36.271 READ FPDMA QUEUED | |
Error 23285 occurred at disk power-on lifetime: 6540 hours (272 days + 12 hours) | |
When the command that caused the error occurred, the device was active or idle. | |
After command completion occurred, registers were: | |
ER ST SC SN CL CH DH | |
-- -- -- -- -- -- -- | |
40 51 08 08 08 00 00 Error: UNC at LBA = 0x00000808 = 2056 | |
Commands leading to the command that caused the error were: | |
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name | |
-- -- -- -- -- -- -- -- ---------------- -------------------- | |
60 08 48 00 0a c0 40 08 00:00:32.266 READ FPDMA QUEUED | |
60 08 40 00 09 c0 40 08 00:00:32.265 READ FPDMA QUEUED | |
60 08 00 00 0c 80 40 08 00:00:32.257 READ FPDMA QUEUED | |
60 08 f8 00 0a 80 40 08 00:00:32.256 READ FPDMA QUEUED | |
60 08 10 08 08 00 40 08 00:00:32.239 READ FPDMA QUEUED | |
Error 23284 occurred at disk power-on lifetime: 6540 hours (272 days + 12 hours) | |
When the command that caused the error occurred, the device was active or idle. | |
After command completion occurred, registers were: | |
ER ST SC SN CL CH DH | |
-- -- -- -- -- -- -- | |
40 51 08 08 08 00 00 Error: UNC at LBA = 0x00000808 = 2056 | |
Commands leading to the command that caused the error were: | |
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name | |
-- -- -- -- -- -- -- -- ---------------- -------------------- | |
60 08 e0 00 09 80 40 08 00:00:28.357 READ FPDMA QUEUED | |
60 08 38 80 08 c0 40 08 00:00:28.357 READ FPDMA QUEUED | |
60 08 d8 80 08 80 40 08 00:00:28.356 READ FPDMA QUEUED | |
60 08 30 40 08 c0 40 08 00:00:28.356 READ FPDMA QUEUED | |
60 08 d0 40 08 80 40 08 00:00:28.356 READ FPDMA QUEUED | |
SMART Self-test log structure revision number 1 | |
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error | |
# 1 Short offline Completed: read failure 50% 6252 3408 | |
SMART Selective self-test log data structure revision number 1 | |
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS | |
1 0 0 Not_testing | |
2 0 0 Not_testing | |
3 0 0 Not_testing | |
4 0 0 Not_testing | |
5 0 0 Not_testing | |
Selective self-test flags (0x0): | |
After scanning selected spans, do NOT read-scan remainder of disk. | |
If Selective self-test is pending on power-up, resume after 0 minute delay. |