These are are some notes I put together on butchering the rectangular dishy cable.
FOLLOW THESE GUIDELINES AT YOUR OWN RISK. I TAKE NO RESPONSIBILITY FOR ANY DAMAGE OR INJURY YOU SUSTAIN FROM FOLLOWING OR NOT FOLLOWING THESE GUIDELINES.
In general, if you can get away with using the original 75' cable (or the official 150' long replacement cable), then that is ultimately preferable to doing any of this stuff. If you don't already know why you would want to do this then you definitely shouldn't do it. If you run into trouble, the first thing Starlink Support is going to ask is if the cable between your dishy and router has any modifications, and for good reason.
Despite the connectors being proprietary, the underlying technology connecting the router and the rectangular dishy is gigabit ethernet with non-standard PoE(The orange and green pairs are positive, the blue and brown pairs are negative). The cable itself is plain stranded STP CAT5e, suitable for outdoor use. The router acts as a 48V, 2A PoE power supply, so 96 watts are available at the port the router.
Stick with the original router (and possibly the ethernet port dongle) unless you have a good reason to try something else. You cannot power dishy with a standard PoE injector, but if you are enterprising enough you can rearrange the wires (swap blue/green, terminate as Type-B) going into and out-of a passive 4-pair PoE Injector and get it working with a sufficiently large 48V or 52V DC power supply.
Note that most 48V 2A power supplies on Amazon are insufficient! I recommend this 52V power supply, as I have confirmed that it works and I am using it on my own 200+ft run.
Resistance is the primary limiting factor you will run into. As you increase the length of the cable and add additional terminations/connectors, resistance increases. If the resistance is too high, the voltage at the dishy will (perhaps only occasionally) drop too low, causing it to spuriously reboot or not boot at all.
The exact maximum round-trip power resistance that the cable can have before Dishy's stability suffers isn't immediately clear, but 1.8Ω round-trip (~88 watts available for Dishy) appears to be stable while 2.5Ω round-trip is just barely unstable. (neither value includes the resistance of about 20 extra feet of the original CAT5e that is used in my setup)
If you cannot easily measure resistance, you will need to be as conservative as possible:
- Keep the length of your entire run as short as possible and your connectors as few as possible. Continuous runs are almost always preferable to runs with connectors.
- Use outdoor-rated cable for outdoor runs. If riser cable is all you have, paint it.
- Don't directly bury the cable unless it is rated for direct burial. Otherwise, water intrusion will eventually make your connection unreliable. The original cable is NOT rated for direct burial.
- Use 23AWG (or larger) CAT6/CAT6A cable, which will contribute around 0.03Ω/meter for a continuous run.
- The original cable was only 24AWG, so if you are using 23AWG cable then the less length you use from the original cable the better.
- It would appear that connectors will each contribute ~0.02-0.1Ω to the round-trip resistance, but more research is required.
- Avoid unnecessary use of patch panels, they introduce additional connectors and add resistance.
- 150' is likely the most distance you are going to get without changing your approach (like splitting out the power into larger guage wires, etc), but if you use a specialty low-resistance cable (like this) then you might be able to almost double that with some careful terminations.
- Once you get everything set up, try turning on snow pre-heat mode:
- If you can run a few speed tests in a row without problems, then you are likely golden.
- If your dishy reboots (either immediately or after running a few speed tests), your cable resistance is too high.
For longer runs you may need to use a power supply with a larger voltage. I can confirm that the rectangular dishy works fine on 52V.
With a longer run, proper grounding and surge protection becomes more important. Dishy must be grounded in some way. With the unmodified original cable, that grounding comes from the router. Since we are cutting that wire, we need to make sure that we provide that grounding.
- At least the the first RJ45 termination on the dishy side should be a grounded RJ45 plug.
- Use a high-quality, grounded, PoE-compatable ethernet surge
protector at the termination closest to your dishy.
- If you do this at your "service entrance" (where the wire enters your house), then you won't need a shielded ethernet cable after that point---but you might want it to be shielded to reduce RF interference.
- If you do use a shielded cable after the grounded surge protector, make sure you don't have a continuous ground between your surge protector and your Starlink router---that would create a ground loop, and you don't want that. If there is a ground fault, some of the surge current could go through your shielding!
- Alternatively, you could forgo the surge protector and use shielded cables, connectors, and plugs for the entire run and ensure continuity between the starlink router and dishy (presumably the router has some amount of built-in surge protection).
Sorry, the standard Starlink cable is 50 feet. It's in their specs, and I confirmed it by measuring the old one that I pulled out.
https://www.starlink.com/specifications
Starlink doesn't say whether it's Cat 5e or Cat 6a. I've seen it described both ways, but as I write I'm inclined to say Cat 5e. That would be 24 AWG. Ampacity for 24 AWG is 3.5.
https://www.engineeringtoolbox.com/wire-gauges-d_419.html
Now for the fun stuff. When my router is plugged in without the cable plugged in, it registers 0.07A at the indoor outlet. When the cable is plugged in, it registers 0.37A. Both numbers vary a bit but not much; the dish is drawing about 0.3A minus whatever resistance is in 50 feet of 24AWG and two connectors. That 0.3A is measured at the outlet, but there's a step-down transformer in the router that converts 120 volts to 48 volts. This turns 0.3A into 0.75A. Doesn't change the wattage: still 36 watts
My next door neighbor, also a Starlink user whose cable crapped out, measured 5A at the wall outlet last winter with Snow Melt running. Subtracting the 0.07A that the router uses, you get 4.93A delivered to the 48 volt power supply. Voltage stepped down, amperage stepped up to 12.5 over wiring rated for 3.5A . Either way, about 600 watts. (Okay, 591.6 minus a smidgen of power loss in the transformer.) It's becoming clear to me just why so many Starlink cables are failing. Would you use Cat 5e (or Cat 6a) to run power to a space heater?
Now that Starlink is fully commercial, it's becoming popular in rural areas. In places like mine, where it's cold enough to trigger the Snow Melt thermostat off and on for maybe half the year if left on the default "automatic" setting, I think this wiring is getting damaged a little bit each time until it finally gives out. I also note that the Starlink router label shows that it's a 2A device, yet my neighbor observed that it was drawing 5A when Snow Melt was running. I wonder if Snow Melt is frying both the routers and the cables.
My big remaining question is: How long does Snow Melt go on when it goes on? My guess is "not for long enough to fry the cables right away." This is why, when I click around and see reports of bad cables, the story is almost always that it worked for X months then suddenly stopped. In any case I will check that this coming December. When there's a storm, I'll sit next to the meter, turn on Snow Melt and watch what happens, and for how long. I see that Starlink says the dish will melt 1.5" of snow per hour. Sorry, that tells me nothing. At what angle? And what triggers its activation?
I am not an electrician. Didn't take Electrician 101 at the community college. I've had to do a bunch of research to figure this out, but the closer I look the more I think this explains a widespread Starlink problem. Finally, we might ask how something this basic and frankly stupid could happen (if I'm correct, that is.) The answer would be rocket science. Musk & Co. put all their brain cells into the rockets, the satellites, and the dishes, and wound up "assuming" the routers and cables. Kind of like when the space shuttle geniuses assumed those O-rings. Smart people are no less inclined to be oblivious than anyone else.
FINALLY ... if anyone can tell me how I'm wrong about this, I am much, MUCH more receptive to correction than it might seem.