POST
https://api.spanet.net.au/api/MemberLogin
Request:
{
"login": [Username],
"api_key": "4a483b9a-8f02-4e46-8bfa-0cf5732dbbd5",
"password": [Password]
}
Response:
{
"data": {
"email": null,
"id_member": [MemberId],
"login": [Username],
"name": null,
"password": null,
"notification_enabled": 1,
"id_session": [SessionId]
},
"error": null,
"error_code": null,
"message": null,
"success": true
}
GET
https://api.spanet.net.au/api/membersockets?id_member=[MemberId]&id_session=[SessionId]
Response:
{
"data": {
"email": null,
"id_member": 0,
"login": null,
"name": null,
"password": null,
"notification_enabled": 0,
"id_session": null
},
"sockets": [{
"id": [SocketId],
"active": "1",
"id_member": [MemberId],
"id_sockets": [SocketId],
"mac_addr": [MacAddress],
"moburl": [WebSocketUrl]:9090,
"name": [SpaName],
"spaurl": [WebSocketUrl]:9090,
"signalStrength": -69,
"error": false
}],
"error": null,
"error_code": null,
"message": "",
"success": true
}
Open TCP Socket to [WebUrl]
port 9090
, then send..
Request:
<connect--[SocketId]--[MemberId]>
Response:
Successfully connected
Get the current status of the spa.
Request:
RF\n
Sample Response:
RF:
,R2,18,250,51,70,4,13,50,55,19,6,2020,376,9999,1,0,490,207,34,6000,602,23,20,0,0,0,0,44,35,45,:
,R3,32,1,4,4,4,SW V5 17 05 31,SV3,18480001,20000826,1,0,0,0,0,0,NA,7,0,470,Filtering,4,0,7,7,0,0,:
,R4,NORM,0,0,0,1,0,3547,4,20,4500,7413,567,1686,0,8388608,0,0,5,0,98,0,10084,4,80,100,0,0,4,:
,R5,0,1,0,1,0,0,0,0,0,0,1,0,1,0,376,0,3,4,0,0,0,0,0,1,2,6,:
,R6,1,5,0,2,5,8,1,360,1,0,3584,5120,127,128,5632,5632,2304,1792,0,30,0,0,0,0,2,3,0,:
,R7,2304,0,1,1,1,0,1,0,0,0,253,191,253,240,483,125,77,1,0,0,0,23,200,1,0,1,31,32,35,100,5,:
,R9,F1,255,0,0,0,0,0,0,0,0,0,0,:
,RA,F2,0,0,0,0,0,0,255,0,0,0,0,:
,RB,F3,0,0,0,0,0,0,0,0,0,0,0,:
,RC,0,1,1,0,0,0,0,0,0,2,0,0,1,0,:
,RE,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,1,0,0,0,0,0,0,0,-4,13,30,8,5,1,0,0,0,0,0,:*
,RG,1,1,1,1,1,1,1-1-014,1-1-01,1-1-01,0-,0-,0,:*
Set the target temperature for the spa.
Request:
W40:nnn
Response:
nnn
where nnn
denotes temperature in celsius * 10 between 5.0
-41.0
c (ie: for 35.6c, nnn
= 356)
Start (or cancel) a Clean cycle.
Request:
W12
Response:
W12
Control Pump 1.
Request:
S22:n
Response:
S22-OK
where n
denotes
0
- Off1
- On4
- Auto
Control Pump 2.
Request:
S23:n
Response:
S23-OK
where n
denotes
0
- Off1
- On
Control Pump 3.
Request:
S24:n
Response:
S24-OK
where n
denotes
0
- Off1
- On
Control the Blower.
Request:
S28:n
Response:
S28-OK
where n
denotes
0
- Variable1
- Ramp2
- Off
Set the variable speed of the blower.
Request:
S13:n
Response:
n S13
where n
denotes speed 1
-5
TODO
Set the Operation mode.
Request:
W66:n
Response:
n
where n
denotes
0
- Norm1
- Econ2
- Away3
- Week
Set the filtration runtime.
Request:
W60:n
Response:
n
where n
denotes hours between 1
-24
.
Set the time between filtration cycles.
Request:
W90:n
Response:
n
where n
denotes hours as
1
- 1 hr2
- 2 hr3
- 3 hr4
- 4 hr6
- 6 hr8
- 8 hr12
- 12 hr24
- 24 hr
TODO
Set the Power Save option.
Request:
W63:n
Response:
n
where n
denotes
0
- Off1
- Low2
- High
TODO
TODO
TODO
TODO
TODO
Set the Lock Mode.
Request:
S21:n
Response:
n
where n
denotes
0
- Off1
- Partial2
- Full
TODO
I have completed and testing my unit now, it took two orders due to an issue with the first but here is the final unit and it works well. for more pictures and code check the link https://github.com/shanekuz/SPANETMCU it includes the gerber files so you can just order on line.