blueprint: | |
name: Appliance has finished | |
description: Do something when an appliance (like a washing machine or dishwasher has finished as detected by a power sensor. | |
domain: automation | |
input: | |
power_sensor: | |
name: Power Sensor | |
description: Power sensor entity (e.g. from a smart plug device). | |
selector: | |
entity: | |
domain: sensor | |
starting_threshold: | |
name: Starting power threshold | |
description: Power threshold above which we assume the appliance has started. | |
default: 5 | |
selector: | |
number: | |
min: 1.0 | |
max: 100.0 | |
unit_of_measurement: W | |
mode: slider | |
step: 1.0 | |
starting_hysteresis: | |
name: Starting hysteresis | |
description: Time duration the power measurement has to stay above the starting | |
power threshold. | |
default: 5 | |
selector: | |
number: | |
min: 0.25 | |
max: 60.0 | |
unit_of_measurement: min | |
mode: slider | |
step: 0.25 | |
finishing_threshold: | |
name: Finishing power threshold | |
description: Power threshold below which we assume the appliance has finished. | |
default: 5 | |
selector: | |
number: | |
min: 1.0 | |
max: 100.0 | |
unit_of_measurement: W | |
mode: slider | |
step: 1.0 | |
finishing_hysteresis: | |
name: Finishing hysteresis | |
description: Time duration the power measurement has to stay below the finishing power threshold. | |
default: 5 | |
selector: | |
number: | |
min: 0.25 | |
max: 60.0 | |
unit_of_measurement: min | |
mode: slider | |
step: 0.25 | |
off_threshold: | |
name: Machine Off threshold | |
description: Power threshold above which we assume the appliance is turned off. | |
default: 1 | |
selector: | |
number: | |
min: 0.0 | |
max: 5.0 | |
unit_of_measurement: W | |
mode: slider | |
step: 0.1 | |
off_hysteresis: | |
name: Machine Off hysteresis | |
description: Time duration the power measurement has to stay above the Machine Off threshold power threshold. | |
default: 1 | |
selector: | |
number: | |
min: 0.25 | |
max: 60.0 | |
unit_of_measurement: min | |
mode: slider | |
step: 0.25 | |
actions: | |
name: Actions | |
description: Actions (e.g. pushing a notification, TTS announcement, ...) | |
selector: | |
action: {} | |
pre_actions: | |
name: Actions | |
description: Actions when starting threshhold is crossed | |
selector: | |
action: {} | |
off_actions: | |
name: Actions | |
description: Actions when offlibe threshhold is crossed | |
selector: | |
action: {} | |
source_url: https://gist.github.com/dotWee/2eabe1b049e51e73361a516e41be1f2c | |
trigger: | |
- platform: numeric_state | |
entity_id: !input 'power_sensor' | |
for: | |
minutes: !input 'starting_hysteresis' | |
above: !input 'starting_threshold' | |
condition: [] | |
action: | |
- choose: [] | |
default: !input pre_actions | |
- wait_for_trigger: | |
- platform: numeric_state | |
entity_id: !input power_sensor | |
below: !input finishing_threshold | |
for: | |
minutes: !input finishing_hysteresis | |
- choose: [] | |
default: !input actions | |
- wait_for_trigger: | |
- platform: numeric_state | |
entity_id: !input power_sensor | |
below: !input off_threshold | |
for: | |
minutes: !input off_hysteresis | |
- choose: [] | |
default: !input off_actions | |
mode: single | |
max_exceeded: silent |