#requires -version 3 | |
<# | |
.SYNOPSIS | |
Get-ProliantDiskDrives - Get HP ProLiant disk drive status for PRTG | |
.DESCRIPTION | |
Reads the status of HP ProLiant Smart Array disk drives via WMI and HP WBEM | |
http://www.hp.com/go/HPwbem | |
.OUTPUTS | |
XML formatted for a PRTG Advanced Script Sensor. | |
Numeric status per channel as per $statusDMTF and $statusHPExtended below | |
.LINK | |
http://daniel.streefkerkonline.com/monitoring-hp-proliant-via-powershell-wmi-drive-health/ | |
.NOTES | |
Written By: Daniel Streefkerk | |
Website: http://daniel.streefkerkonline.com | |
Twitter: http://twitter.com/dstreefkerk | |
Todo: Nothing at the moment | |
Change Log | |
https://gist.github.com/dstreefkerk/10224178 | |
#> | |
Param( | |
[Parameter(Position=0,Mandatory=$true,ValueFromPipeline=$false,HelpMessage='Name of the server to connect to')] | |
[String] | |
$ServerName | |
) | |
# Capitalise the server name, just for display purposes later | |
$ServerName = $($ServerName.ToUpper()) | |
$statusDMTF = @{ | |
'0' = 'Unknown' | |
'1' = 'Other' | |
'2' = 'OK' | |
'3' = 'Degraded' | |
'4' = 'Stressed' | |
'5' = 'Predictive Failure' | |
'6' = 'Error' | |
'7' = 'Non-Recoverable Error' | |
'8' = 'Starting' | |
'9' = 'Stopping' | |
'10' = 'Stopped' | |
'11' = 'In Service' | |
'12' = 'No Contact' | |
'13' = 'Lost Communication' | |
'14' = 'Aborted' | |
'15' = 'Dormant' | |
'16' = 'Supporting Entity in Error' | |
'17' = 'Completed' | |
'18' = 'Power Mode' | |
'19' = 'Relocating' | |
} | |
$statusHPExtended = @{ | |
'32768' = 'Queued for Secure Erase' | |
'32769' = 'Erase in Progress' | |
'32770' = 'Erase Completed' | |
'32771' = 'Physical Path In Error' | |
'32772' = 'Transient Data Drive' | |
'32773' = 'Rebuild' | |
'32774' = 'SSDWearOut' | |
'32775' = 'Not Authenticated' | |
} | |
# First, test that we can use WMI | |
$wmiErrorVariable = @() | |
try { | |
$computerSystem = Get-WmiObject -Namespace ROOT\CIMV2 -Class Win32_ComputerSystem -ComputerName $ServerName -ErrorAction Stop -WarningAction SilentlyContinue -ErrorVariable wmiErrorVariable | |
} | |
catch [System.UnauthorizedAccessException] { | |
$wmiError = $true | |
$wmiErrorMessage = "WMI Access to $ServerName is denied. Error: $($_.Exception.Message)" | |
} | |
catch [System.Runtime.InteropServices.COMException] { | |
$wmiError = $true | |
$wmiErrorMessage = "Couldn't query $ServerName via WMI. Error: $($_.Exception.Message)" | |
} | |
catch { | |
$wmiError = $true | |
$wmiErrorMessage = $_.Exception.Message | |
} | |
finally { | |
if ($wmiError -eq $true) { | |
"<prtg>" | |
"<error>1</error>" | |
"<text>$wmiErrorMessage $($_.Exception.Message)</text>" | |
"</prtg>" | |
Exit | |
} | |
} | |
# Get all disks via WMI | |
$disks = Get-WmiObject -Namespace ROOT\HPQ -Class HPSA_DiskDrive -ComputerName $ServerName -WarningAction SilentlyContinue -ErrorAction SilentlyContinue -ErrorVariable wmiError | |
# If the ROOT\HPQ WMI query failed, throw an error. | |
if ($wmiError.Count -gt 0) { | |
"<prtg>" | |
"<error>1</error>" | |
"<text>The Insight WBEM Management Providers don't seem to be installed on $($ServerName.ToUpper()). Error: $($wmiError.Exception.Message)</text>" | |
"</prtg>" | |
Exit | |
} | |
$diskObjectCollection = @() | |
foreach ($disk in $disks) { | |
$thisDisk = New-Object psobject | |
# Display name for the channel | |
$diskName = "$($disk.ElementName) - $($disk.Description) Disk $($disk.Name)" | |
# Base operational status in textual form | |
$baseStatus = $disk.OperationalStatus[0] | |
# Extended operational status in textual form | |
$extendedStatus = $disk.OperationalStatus[1] | |
# Set some properties we'll use later | |
$thisDisk | Add-Member -MemberType "NoteProperty" -Name "Name" -Value $diskName | |
#Uncomment the below line, and comment out the line below it to get a textual representation of the status instead of a number | |
#$thisDisk | Add-Member -MemberType "NoteProperty" -Name "OperationalStatus" -Value $statusDMTF["$baseStatus"] | |
$thisDisk | Add-Member -MemberType "NoteProperty" -Name "OperationalStatus" -Value $baseStatus | |
#Uncomment the below line, and comment out the line below it to get a textual representation of the status instead of a number | |
#$thisDisk | Add-Member -MemberType "NoteProperty" -Name "ExtendedOperationalStatus" -Value $statusHPExtended["$extendedStatus"] | |
$thisDisk | Add-Member -MemberType "NoteProperty" -Name "ExtendedOperationalStatus" -Value "$extendedStatus" | |
# If the Operational Status of the disk isn't equal to 2 (OK), we'll be setting the whole PRTG sensor to error | |
if ($baseStatus -ne 2) { | |
$thisDisk | Add-Member -MemberType NoteProperty -Name "Error" -Value $true | |
$thisDisk | Add-Member -MemberType NoteProperty -Name "StateMessage" -Value "$diskName has the following operational status: $($statusDMTF["$baseStatus"])/$($statusHPExtended["$extendedStatus"])). " | |
} else { | |
$thisDisk | Add-Member -MemberType NoteProperty -Name "Error" -Value $false | |
$thisDisk | Add-Member -MemberType NoteProperty -Name "StateMessage" -Value $null | |
} | |
# Add this custom object to the collection | |
$diskObjectCollection += $thisDisk | |
} | |
# If you don't use PRTG, you could just un-comment the below line | |
#$diskObjectCollection | ft -AutoSize; exit; | |
"<prtg>" | |
foreach ($diskObject in $diskObjectCollection) { | |
"<result>" | |
"<channel>$($diskObject.name)</channel>" | |
# Display the status message in the channel | |
if ($diskObject.ExtendedOperationalStatus -gt 0) { | |
"<value>$($diskObject.OperationalStatus).$($diskObject.ExtendedOperationalStatus)</value>" | |
} else { | |
"<value>$($diskObject.OperationalStatus)</value>" | |
} | |
# Set the channel to warning status if there operational status isn't as it should be | |
if ($diskObject.Error -eq $true) { | |
"<warning>1</warning>" | |
} | |
"</result>" | |
} | |
# If any of the disks are in error, output their status to the sensor's message field. | |
if (($diskObjectCollection | where error -eq $true).count -gt 0) { | |
"<error>1</error>" | |
"<text>$($diskObjectCollection | where error -eq $true | % {$($_.StateMessage)})</text>" | |
} | |
"</prtg>" |