Woox R7051 Z2M converter with siren volume,brightness,duration
controls exposed
r7051.js
:
const fz = require('zigbee-herdsman-converters/converters/fromZigbee');
const tz = require('zigbee-herdsman-converters/converters/toZigbee');
const exposes = require('zigbee-herdsman-converters/lib/exposes');
const reporting = require('zigbee-herdsman-converters/lib/reporting');
const extend = require('zigbee-herdsman-converters/lib/extend');
const ota = require('zigbee-herdsman-converters/lib/ota');
const tuya = require('zigbee-herdsman-converters/lib/tuya');
const {} = require('zigbee-herdsman-converters/lib/tuya');
const utils = require('zigbee-herdsman-converters/lib/utils');
const globalStore = require('zigbee-herdsman-converters/lib/store');
const e = exposes.presets;
const ea = exposes.access;
const woox = {
fz: {
siren_brightness: {
cluster: 'ssIasWd',
type: ['attributeReport', 'readResponse'],
convert: (model, msg, publish, options, meta) => {
const result = {};
if (msg.data.hasOwnProperty('1')) {
result['brightness'] = msg.data['1'];
}
return result;
},
},
siren_duration_volume: {
cluster: 'ssIasWd',
type: ['attributeReport', 'readResponse'],
convert: (model, msg, publish, options, meta) => {
const result = {};
if (msg.data.hasOwnProperty('maxDuration')) result['duration'] = msg.data.maxDuration;
if (msg.data.hasOwnProperty('2')) {
result['volume'] = msg.data['2'];
}
return result;
},
},
},
tz: {
ts0219_brightness: {
key: ['brightness'],
convertSet: async (entity, key, value, meta) => {
await entity.write('ssIasWd', {0x0001: {value: value, type: 0x20}});
},
convertGet: async (entity, key, meta) => {
await entity.read('ssIasWd', [0x0001]);
},
},
},
};
const definition = {
fingerprint: [{ modelID: 'TS0219', manufacturerName: '_TYZB01_ynsiasng' }],
zigbeeModel: ['TS0219'],
model: 'R7051',
vendor: 'Woox',
description: 'Smart Indoor Siren',
fromZigbee: [fz.battery, fz.power_source, fz.ias_alarm_only_alarm_1, woox.fz.siren_brightness, woox.fz.siren_duration_volume],
toZigbee: [tz.ts0216_alarm, woox.tz.ts0219_brightness, tz.ts0216_duration, tz.ts0216_volume],
exposes: [e.battery(), e.battery_voltage(), e.binary('alarm', ea.STATE, true, false),
e.binary('ac_connected', ea.STATE, true, false).withDescription('Is the device plugged in'),
e.binary('alarm', ea.STATE_SET, true, false).withDescription('Manual start of siren'),
e.numeric('volume', ea.ALL).withValueMin(0).withValueMax(100).withDescription('Volume of siren'),
e.numeric('duration', ea.ALL).withValueMin(0).withValueMax(3600).withDescription('Duration of siren'),
e.numeric('brightness', ea.ALL).withValueMin(0).withValueMax(100).withDescription('Brightness of siren')],
meta: { disableDefaultResponse: true },
configure: async (device, coordinatorEndpoint, logger) => {
const endpoint = device.getEndpoint(1);
const bindClusters = ['genPowerCfg'];
await reporting.bind(endpoint, coordinatorEndpoint, bindClusters);
await reporting.batteryVoltage(endpoint);
await reporting.batteryPercentageRemaining(endpoint);
if (device.powerSource == 'Mains (3 phase)') {
device.powerSource = 'Mains (single phase)';
} else if (device.powerSource == 'Emergency mains and transfer switch') {
device.powerSource = 'Battery';
}
},
};
module.exports = definition;
- Place
r7051.js
file inside thedata
folder (see external-converters for the details) - Add the following lines to the
configuration.yaml
:
external_converters:
- r7051.js
- Restart Z2M
To trigger your siren send the following payload to the respective z2m mqtt topic, like zigbee2mqtt/woox_buzzer/set
:
{"duration": 2, "brightness":50, "volume": 50, "alarm": true}
Yes, for sure we need full zigbee traffic dump between hub and siren to figure out DPs responsible for sound and color configuration. This device appears to be Tuya under the hood and there are several variations of this siren just branded differently but having the same hw/fw actually. And tuya is known for zigbee protocol violations, making a kind of proprietary 'extensions' to it.