zigpy quirk for TS011F Circuit Breaker * Tongou TO-Q-SY2-JZT and others
"""TS011F Circuit Breaker * Tongou TO-Q-SY2-JZT."""
"""Supports HA 2024.11"""
from typing import Any, Optional, Union
import logging
import enum
from struct import (iter_unpack, pack)
from zigpy.profiles import zgp, zha
from zigpy.quirks.v2 import (
QuirkBuilder,
CustomDeviceV2
)
from zigpy.quirks.v2.homeassistant import (
UnitOfTemperature,
UnitOfElectricPotential,
UnitOfElectricCurrent,
UnitOfPower
)
from zigpy.quirks.v2.homeassistant.number import NumberDeviceClass
import zigpy.types as t
from zigpy.zcl import foundation
from zhaquirks import LocalDataCluster
from zhaquirks.quirk_ids import TUYA_PLUG_ONOFF
from zhaquirks.tuya import (
EnchantedDevice,
TuyaNewManufCluster,
TuyaZB1888Cluster,
TuyaZBE000Cluster,
TuyaZBElectricalMeasurement,
TuyaZBExternalSwitchTypeCluster,
TuyaZBMeteringCluster,
TuyaZBMeteringClusterWithUnit,
TuyaZBOnOffAttributeCluster,
TuyaLocalCluster,
)
_LOGGER = logging.getLogger("ts011f")
TUYA_OPTIONS_2_DATA = 0xE6
TUYA_OPTIONS_3_DATA = 0xE7
class Breaker(t.enum8):
Off = 0x00
On = 0x01
class TuyaZBExternalSwitchTypeThresholdCluster(LocalDataCluster, TuyaZBExternalSwitchTypeCluster):
"""Tuya External Switch Type With Threshold Cluster."""
name = "Tuya External Switch Type With Threshold Cluster"
ep_attribute = "tuya_external_switch_type_threshold"
class AttributeDefs(TuyaZBExternalSwitchTypeCluster.AttributeDefs):
"""Attribute definitions."""
temperature_breaker = foundation.ZCLAttributeDef(
id=0xe605, type=Breaker, is_manufacturer_specific=True, zcl_type=foundation.DataTypeId.uint8
)
temperature_threshold = foundation.ZCLAttributeDef(
id=0xe685, type=t.uint16_t, is_manufacturer_specific=True
)
power_breaker = foundation.ZCLAttributeDef(
id=0xe607, type=Breaker, is_manufacturer_specific=True, zcl_type=foundation.DataTypeId.uint8
)
power_threshold = foundation.ZCLAttributeDef(
id=0xe687, type=t.uint16_t, is_manufacturer_specific=True
)
over_current_breaker = foundation.ZCLAttributeDef(
id=0xe701, type=Breaker, is_manufacturer_specific=True, zcl_type=foundation.DataTypeId.uint8
)
over_current_threshold = foundation.ZCLAttributeDef(
id=0xe781, type=t.uint16_t, is_manufacturer_specific=True
)
over_voltage_breaker = foundation.ZCLAttributeDef(
id=0xe703, type=Breaker, is_manufacturer_specific=True, zcl_type=foundation.DataTypeId.uint8
)
over_voltage_threshold = foundation.ZCLAttributeDef(
id=0xe783, type=t.uint16_t, is_manufacturer_specific=True
)
under_voltage_breaker = foundation.ZCLAttributeDef(
id=0xe704, type=Breaker, is_manufacturer_specific=True, zcl_type=foundation.DataTypeId.uint8
)
under_voltage_threshold = foundation.ZCLAttributeDef(
id=0xe784, type=t.uint16_t, is_manufacturer_specific=True
)
class ServerCommandDefs(TuyaZBExternalSwitchTypeCluster.ServerCommandDefs):
"""Server command definitions."""
set_options_2 = foundation.ZCLCommandDef(
TUYA_OPTIONS_2_DATA,
{"data?": t.SerializableBytes},
False,
is_manufacturer_specific=True,
)
set_options_3 = foundation.ZCLCommandDef(
TUYA_OPTIONS_3_DATA,
{"data?": t.SerializableBytes},
False,
is_manufacturer_specific=True,
)
def handle_cluster_request(
self,
hdr: foundation.ZCLHeader,
args: tuple,
*,
dst_addressing: Optional[
Union[t.Addressing.Group, t.Addressing.IEEE, t.Addressing.NWK]
] = None,
) -> None:
"""Handle cluster request."""
data = args
_LOGGER.debug(
"[0x%04x:%s:0x%04x] Received value %s "
"for attribute 0x%04x (command 0x%04x)",
self.endpoint.device.nwk,
self.endpoint.endpoint_id,
self.cluster_id,
repr(data),
hdr.command_id,
hdr.command_id,
)
if hdr.command_id in (TUYA_OPTIONS_2_DATA, TUYA_OPTIONS_3_DATA):
for (attr_id, breaker, threshold) in iter_unpack('>bbH', data):
self._update_attribute((hdr.command_id << 8) + attr_id, breaker)
self._update_attribute((hdr.command_id << 8) + 0x80 + attr_id, threshold)
super().handle_cluster_request(
hdr, args, dst_addressing=dst_addressing
)
async def write_attributes(self, attributes, manufacturer=None):
"""Defer attributes writing to the set_options_* command."""
local, remote = {}, {}
remote_attr_ids = list(map(lambda attrDef: attrDef.id, TuyaZBExternalSwitchTypeCluster.AttributeDefs))
for key, value in attributes.items():
if key in TuyaZBExternalSwitchTypeCluster.AttributeDefs or key in remote_attr_ids:
remote[key] = value
else:
local[key] = value
_LOGGER.debug('write_attributes attrs: %s local: %s remote %s', repr(attributes), repr(local), repr(remote))
if local:
records = self._write_attr_records(local)
_LOGGER.debug('write_attributes records: %s ', repr(records))
command_attributes = {
TUYA_OPTIONS_2_DATA: {},
TUYA_OPTIONS_3_DATA: {}
}
for attribute in records:
attr_id = attribute.attrid
command_id = attr_id >> 8
comp_attr_id = attr_id ^ 0x80
if not attr_id in command_attributes[command_id]:
if comp_attr_id in local:
comp_attr = next(filter(lambda a: a.id == comp_attr_id, records), None)
comp_value = comp_attr.value.value
else:
comp_value = self.get(comp_attr_id)
if comp_value != None:
command_attributes[command_id][attr_id & 0x7F] = {
((attr_id & 0x80) >> 7) : attribute.value.value,
((comp_attr_id & 0x80) >> 7): comp_value,
}
for command_id, command_attribute in command_attributes.items():
if command_attribute:
data = bytearray(b'')
for attr_id, values in command_attribute.items():
data.extend(pack(">bbH", attr_id, values[0], values[1]))
await super().command(command_id, data)
if remote:
await TuyaZBExternalSwitchTypeCluster.write_attributes(self, remote, manufacturer)
return [[foundation.WriteAttributesStatusRecord(foundation.Status.SUCCESS)]]
async def read_attributes(
self,
attributes: list[int | str],
allow_cache: bool = False,
only_cache: bool = False,
manufacturer: int | t.uint16_t | None = None,
) -> Any:
local_success, local_failure = {}, {}
remote_success, remote_failure = {}, {}
local, remote = [], []
remote_attr_ids = list(map(lambda attrDef: attrDef.id, TuyaZBExternalSwitchTypeCluster.AttributeDefs))
for attribute in attributes:
if isinstance(attribute, str):
attrid = self.attributes_by_name[attribute].id
else:
# Allow reading attributes that aren't defined
attrid = attribute
if attrid in remote_attr_ids:
remote.append(attrid)
else:
local.append(attrid)
_LOGGER.debug('read_attributes attrs: %s local: %s remote %s', repr(attributes), repr(local), repr(remote))
if local:
local_success, local_failure = await LocalDataCluster.read_attributes(self, local, allow_cache, only_cache, manufacturer)
if remote:
remote_success, remote_failure = await TuyaZBExternalSwitchTypeCluster.read_attributes(self, remote, allow_cache, only_cache, manufacturer)
return local_success | remote_success, local_failure | remote_failure
class Plug_CB_Metering_Threshold(CustomDeviceV2, EnchantedDevice):
"""Circuit breaker with monitoring, e.g. Tongou TO-Q-SY2-JZT. First one using this definition was _TZ3000_cayepv1a."""
quirk_id = TUYA_PLUG_ONOFF
(
QuirkBuilder("_TZ3000_cayepv1a", "TS011F")
.also_applies_to("_TZ3000_lepzuhto", "TS011F")
.also_applies_to("_TZ3000_qystbcjg", "TS011F")
.device_class(Plug_CB_Metering_Threshold)
.replaces(TuyaZBOnOffAttributeCluster)
.replaces(TuyaZBMeteringCluster)
.replaces(TuyaZBElectricalMeasurement)
.replaces(TuyaZBE000Cluster)
.replaces(TuyaZBExternalSwitchTypeThresholdCluster)
.switch(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.temperature_breaker.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
fallback_name="Temperature Breaker",
translation_key=TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.temperature_breaker.name
)
.number(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.temperature_threshold.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
min_value=40,
max_value=100,
unit=UnitOfTemperature.CELSIUS,
mode="box",
fallback_name="Temperature Threshold",
device_class=NumberDeviceClass.TEMPERATURE
)
.switch(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.power_breaker.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
fallback_name="Power Breaker",
translation_key=TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.power_breaker.name
)
.number(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.power_threshold.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
min_value=1,
max_value=26,
unit=UnitOfPower.KILO_WATT,
mode="box",
fallback_name="Power Threshold",
device_class=NumberDeviceClass.POWER
)
.switch(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.over_current_breaker.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
fallback_name="Over Current Breaker",
translation_key=TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.over_current_breaker.name
)
.number(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.over_current_threshold.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
min_value=1,
max_value=63,
unit=UnitOfElectricCurrent.AMPERE,
mode="box",
fallback_name="Over Current Threshold",
device_class=NumberDeviceClass.CURRENT
)
.switch(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.over_voltage_breaker.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
fallback_name="Over Voltage Breaker",
translation_key=TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.over_voltage_breaker.name
)
.number(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.over_voltage_threshold.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
min_value=230,
max_value=265,
unit=UnitOfElectricPotential.VOLT,
mode="box",
fallback_name="Over Voltage Threshold",
device_class=NumberDeviceClass.VOLTAGE
)
.switch(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.under_voltage_breaker.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
fallback_name="Under Voltage Breaker",
translation_key=TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.under_voltage_breaker.name
)
.number(
TuyaZBExternalSwitchTypeThresholdCluster.AttributeDefs.under_voltage_threshold.name,
TuyaZBExternalSwitchTypeThresholdCluster.cluster_id,
attribute_initialized_from_cache=False,
min_value=75,
max_value=240,
unit=UnitOfElectricPotential.VOLT,
mode="box",
fallback_name="Under Voltage Threshold",
device_class=NumberDeviceClass.VOLTAGE
)
.add_to_registry()
)
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment