Nedis WIFIDS10WT Tasmota Configuration
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
{"NAME":"Nedis WIFIDS10WT","GPIO":[0,107,0,108,0,0,0,0,0,0,0,0,0],"FLAG":0,"BASE":54} | |
Module 54 | |
Backlog TuyaMCU 11,4; TuyaMCU 51,51 | |
Backlog SetOption1 1; SetOption65 1; SetOption66 1 | |
Rule1 | |
ON TuyaReceived#Data=55AA000500056A0400010078 DO publish2 stat/%topic%/FIRE OFF ENDON | |
ON TuyaReceived#Data=55AA000500056A0400010078 DO publish2 stat/%topic%/TEST OFF ENDON | |
ON TuyaReceived#Data=55AA000500056A0400010078 DO publish2 stat/%topic%/BATTERY OFF ENDON | |
ON TuyaReceived#Data=55AA000500056A0400010078 DO publish2 stat/%topic%/MUTE OFF ENDON | |
ON TuyaReceived#Data=55AA000500056A0400010179 DO publish2 stat/%topic%/FIRE ON ENDON | |
ON TuyaReceived#Data=55AA000500056A0400010179 DO publish2 stat/%topic%/MUTE OFF ENDON | |
ON TuyaReceived#Data=55AA000500056A040001027A DO publish2 stat/%topic%/FIRE ON ENDON | |
ON TuyaReceived#Data=55AA000500056A040001027A DO publish2 stat/%topic%/MUTE ON ENDON | |
ON TuyaReceived#Data=55AA000500056A040001037B DO publish2 stat/%topic%/FIRE ON ENDON | |
ON TuyaReceived#Data=55AA000500056A040001037B DO publish2 stat/%topic%/TEST ON ENDON | |
ON TuyaReceived#Data=55AA000500056A040001037B DO publish2 stat/%topic%/MUTE OFF ENDON | |
ON TuyaReceived#Data=55AA000500056A040001047C DO publish2 stat/%topic%/BATTERY ON ENDON | |
Rule2 | |
ON system#boot do publish2 homeassistant/binary_sensor/%macaddr%_fire/config {"name":"Office Fire Alarm","state_topic":"stat/%topic%/FIRE","device_class":"smoke","unique_id":"%macaddr%_fire","device":{"connections":[["mac","%macaddr%"]]}} ENDON | |
ON system#boot do publish2 homeassistant/binary_sensor/%macaddr%_test/config {"name":"Office Fire Alarm Test","state_topic":"stat/%topic%/TEST","icon":"mdi:bell-alert","unique_id":"%macaddr%_test","device":{"connections":[["mac","%macaddr%"]]}} ENDON | |
ON system#boot do publish2 homeassistant/binary_sensor/%macaddr%_mute/config {"name":"Office Fire Alarm Mute","state_topic":"stat/%topic%/MUTE","icon":"mdi:bell-sleep","unique_id":"%macaddr%_mute","device":{"connections":[["mac","%macaddr%"]]}} ENDON | |
ON system#boot do publish2 homeassistant/binary_sensor/%macaddr%_battery/config {"name":"Office Fire Alarm Battery","state_topic":"stat/%topic%/BATTERY","device_class":"battery","unique_id":"%macaddr%_battery","device":{"connections":[["mac","%macaddr%"]]}} ENDON |
Oh and also you should be able to see the raw tuya messages by listening to the tele/%topic%/RESULT
topic
thanks for the reply.
I flash the device again and reloaded the software. If I press the test button then I see in HA a report of the SSID, address and that sort of things, until the red light dims. Still the other Fire Alarm, Battery remains unknown.
In MQTT Exporer I see tele/tasmota_nnn/INFO1 2 and 3 and then
tele/tasmota_313159/STATE, but no result.
So if I press the button, shhould it then also send this message? Or only weekly?
-- Paul
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Hi @PaulUitWijchen, the device works kind of odd like that. The wifi module stays off by default.
It gets turned on when:
When the wifi module gets turned on, the other MCU on the smoke detector sends a message to it using the Tuya protocol. The rules above get triggered only when such a message is received. In other words, try to trigger the test functionality and listen in on your MQTT topic and see what comes in. You will not receive any status updates otherwise.