Save janstanka/5175e4f01e3f9c98a1469689a4f02cc4 to your computer and use it in GitHub Desktop.
Klipper probe config for the BIQU BX with BTT/BIQU Microprobe (V1/V2)
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
## --- BIQU BX (SKR-BX 2.0) with Microprobe V2 Klipper configuration --- | |
# I used MicroProbe with bracket for Ender3 (SKU: 1060000587*1+1060000658*1) | |
# Not much different from a standard probe config. The | |
# main difference compared to most probes is to disable | |
# deactivating the probe (PROBE_UP) after each sample | |
# Note: if you are changing from a bltouch or one of its | |
# clones, remove/comment out the [bltouch] config! | |
# That also includes any auto generated config stored | |
# at the bottom by the PROBE_CALIBRATE command | |
# | |
# This config is configured for | |
# the V2 microprobe. V1 users must update the | |
# polarity of the sensor pin in the config to be | |
# pull-up (^) not pull up (^!) | |
[gcode_macro PROBE_DOWN] | |
gcode: | |
SET_PIN PIN=probe_enable VALUE=1 | |
[gcode_macro PROBE_UP] | |
gcode: | |
SET_PIN PIN=probe_enable VALUE=0 | |
[output_pin probe_enable] | |
pin: PA2 # Set to the control pin on your board | |
value: 0 | |
[probe] | |
pin: ^!PH2 #V1 users must change to ^PH2 | |
#control_pin: PA2 | |
x_offset: -38 | |
y_offset: 6.5 | |
#z_offset: 5 | |
deactivate_on_each_sample: False | |
samples: 2 | |
samples_tolerance: 0.01 | |
samples_tolerance_retries: 5 | |
activate_gcode: | |
PROBE_DOWN | |
G4 P500 | |
deactivate_gcode: | |
PROBE_UP | |
[bed_mesh] | |
speed: 100 | |
#mesh_min: 29.9,19.78 | |
#mesh_max: 219.9,230 | |
mesh_min: 20.9,9.78 | |
mesh_max: 211.9,240 | |
mesh_pps: 3,3 | |
probe_count: 5,5 | |
algorithm: bicubic | |
fade_start = 1.0 | |
fade_end = 0.0 | |
[z_tilt] | |
speed = 100 | |
horizontal_move_z = 5 | |
retries = 5 | |
retry_tolerance = 0.02 | |
z_positions = | |
275,120 | |
-25,120 | |
points = | |
245,120 | |
# 65,120 | |
45,120 | |
[screws_tilt_adjust] | |
#screw1: 58,-7 | |
screw1: 58,0 | |
screw1_name: front left | |
screw2: 250,0 | |
screw2_name: front right | |
screw3: 250,230 | |
screw3_name: rear right | |
#screw4: 58,179 | |
screw4: 58,230 | |
screw4_name: rear left | |
speed: 100 | |
screw_thread: CCW-M3 |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Connection MicroProbe to BX-Hotmode (extruder board):