From 60472d84c3b438dc09461a6461e82b46a38c3b6a Mon Sep 17 00:00:00 2001
From: Roberto Marques <[email protected]>
Date: Sun, 28 Jun 2020 12:33:29 +0200
Subject: [PATCH] Added experimental support for H110i GT
---
liquidctl/driver/__init__.py | 1 +
liquidctl/driver/coolit.py | 313 +++++++++++++++++++++++++++++++++++
2 files changed, 314 insertions(+)
create mode 100644 liquidctl/driver/coolit.py
diff --git a/liquidctl/driver/__init__.py b/liquidctl/driver/__init__.py
index 2986e1b..1a1e839 100644
--- a/liquidctl/driver/__init__.py
+++ b/liquidctl/driver/__init__.py
@@ -21,6 +21,7 @@
"""
import liquidctl.driver.asetek
+import liquidctl.driver.coolit
import liquidctl.driver.coolit_platinum
import liquidctl.driver.corsair_hid_psu
import liquidctl.driver.kraken_two
diff --git a/liquidctl/driver/coolit.py b/liquidctl/driver/coolit.py
new file mode 100644
index 0000000..0941438
--- /dev/null
+++ b/liquidctl/driver/coolit.py
@@ -0,0 +1,313 @@
+"""liquidctl driver for Corsair Platinum and PRO XT coolers.
+
+Supported devices
+-----------------
+
+ - Corsair H110i GT
+
+Supported features
+------------------
+
+ - general monitoring
+ - pump speed control
+ - fan speed control
+
+Copyright (C) 2020–2020 Jonas Malaco
+Copyright (C) 2020–2020 each contribution's author
+
+SPDX-License-Identifier: GPL-3.0-or-later
+"""
+
+import itertools
+import logging
+
+from enum import Enum, unique
+
+from liquidctl.driver.usb import UsbHidDriver
+from liquidctl.keyval import RuntimeStorage
+from liquidctl.pmbus import compute_pec
+from liquidctl.util import clamp, fraction_of_byte, u16le_from, normalize_profile
+
+
+LOGGER = logging.getLogger(__name__)
+
+_REPORT_LENGTH = 64
+_MAX_FAN_RPM = 2250
+_PUMP_INDEX = 0x02
+
+_COMMAND_FIRMWARE_ID = 0x01
+_COMMAND_TEMP_READ = 0x0E
+_COMMAND_FAN_SELECT = 0x10
+_COMMAND_FAN_MODE = 0x12
+_COMMAND_FAN_FIXED_PWM = 0x13
+_COMMAND_FAN_FIXED_RPM = 0x14
+_COMMAND_FAN_READ_RPM = 0x16
+_COMMAND_FAN_RPM_TABLE = 0x19
+_COMMAND_FAN_TEMP_TABLE = 0x1A
+
+_OP_CODE_WRITE_ONE_BYTE = 0x06
+_OP_CODE_READ_ONE_BYTE = 0x07
+_OP_CODE_WRITE_TWO_BYTES = 0x08
+_OP_CODE_READ_TWO_BYTES = 0x09
+_OP_CODE_WRITE_THREE_BYTES = 0x0A
+_OP_CODE_READ_THREE_BYTES = 0x0B
+
+_PROFILE_LENGTH = 5
+_CRITICAL_TEMPERATURE = 60
+
+_PUMP_DEFAULT_QUIET = [0x2e, 0x09]
+_PUMP_DEFAULT_EXTREME = [0x86, 0x0b]
+
+@unique
+class _FanMode(Enum):
+ FIXED_DUTY = 0x02
+ FIXED_RPM = 0x04
+ CUSTOM_PROFILE = 0x0E
+
+ @classmethod
+ def _missing_(cls, value):
+ LOGGER.debug("falling back to FIXED_DUTY for _FanMode(%s)", value)
+ return _FanMode.FIXED_DUTY
+
+
+@unique
+class _PumpMode(Enum):
+ QUIET = 0x08
+ EXTREME = 0x0C
+
+ @classmethod
+ def _missing_(cls, value):
+ LOGGER.debug("falling back to QUIET for _PumpMode(%s)", value)
+ return _PumpMode.QUIET
+
+
+def _sequence(storage):
+ """Return a generator that produces valid protocol sequence numbers.
+
+ Sequence numbers increment across successful invocations of liquidctl, but
+ are not atomic. The sequence is: 1, 2, 3... 29, 30, 31, 1, 2, 3...
+ """
+ while True:
+ seq = storage.load('sequence', of_type=int, default=0) % 31 + 1
+ storage.store('sequence', seq)
+ yield seq
+
+
+def _prepare_profile(original):
+ clamped = ((temp, clamp(duty, 0, 100)) for temp, duty in original)
+ normal = normalize_profile(clamped, _CRITICAL_TEMPERATURE)
+ missing = _PROFILE_LENGTH - len(normal)
+ if missing < 0:
+ raise ValueError(f'Too many points in profile (remove {-missing})')
+ if missing > 0:
+ normal += missing * [(_CRITICAL_TEMPERATURE, 100)]
+ return normal
+
+
+def _quoted(*names):
+ return ', '.join(map(repr, names))
+
+
+class CoolitDriver(UsbHidDriver):
+ """liquidctl driver for Corsair H110i GT cooler"""
+
+ SUPPORTED_DEVICES = [
+ (0x1B1C, 0x0C04, None, 'Corsair H110i GT (experimental)',
+ {'fan_count': 2, 'rgb_fans': False}),
+ ]
+
+ def __init__(self, device, description, fan_count, rgb_fans, **kwargs):
+ super().__init__(device, description, **kwargs)
+ self._component_count = 1 + fan_count * rgb_fans
+ self._fan_names = [f'fan{i + 1}' for i in range(fan_count)]
+
+ # the following fields are only initialized in connect()
+ self._data = None
+ self._sequence = None
+
+ def connect(self, **kwargs):
+ """Connect to the device."""
+ super().connect(**kwargs)
+ ids = f'{self.vendor_id:04x}_{self.product_id:04x}'
+ self._data = RuntimeStorage(key_prefixes=[ids, self.address])
+ self._sequence = _sequence(self._data)
+
+ def initialize(self, pump_mode='quiet', **kwargs):
+ """Initialize the device and set the pump mode
+
+ The device should be initialized every time it is powered on, including when
+ the system resumes from suspending to memory.
+
+ Valid values for `pump_mode` are 'quiet' and 'extreme'.
+ Unconfigured fan channels may default to 100% duty.
+
+ Returns a list of `(property, value, unit)` tuples.
+ """
+ self._data.store('pump_mode', _PumpMode[pump_mode.upper()].value)
+
+ dataPackages = list()
+ dataPackages.append(self._build_data_package(_COMMAND_FIRMWARE_ID, _OP_CODE_READ_TWO_BYTES))
+
+ res = self._send_command(dataPackages)
+
+ fw_version = (res[3] >> 4, res[3] & 0xf, res[2])
+ return [('Firmware version', '%d.%d.%d' % fw_version, '')]
+
+ def get_status(self, **kwargs):
+ """Get a status report.
+
+ Returns a list of `(property, value, unit)` tuples.
+ """
+ dataPackages = list()
+ dataPackages.append(self._build_data_package(_COMMAND_TEMP_READ, _OP_CODE_READ_TWO_BYTES))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_SELECT, _OP_CODE_WRITE_ONE_BYTE, params=bytes([0])))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_READ_RPM, _OP_CODE_READ_TWO_BYTES))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_SELECT, _OP_CODE_WRITE_ONE_BYTE, params=bytes([1])))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_READ_RPM, _OP_CODE_READ_TWO_BYTES))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_SELECT, _OP_CODE_WRITE_ONE_BYTE, params=bytes([2])))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_READ_RPM, _OP_CODE_READ_TWO_BYTES))
+
+ res = self._send_command(dataPackages)
+
+ temp = res[3] + res[2] / 255
+
+ return [
+ ('Liquid temperature', temp, '°C'),
+ ('Fan 1 speed', u16le_from(res, offset=8), 'rpm'),
+ ('Fan 2 speed', u16le_from(res, offset=14), 'rpm'),
+ ('Pump speed', u16le_from(res, offset=20), 'rpm'),
+ ]
+
+ def set_fixed_speed(self, channel, duty, **kwargs):
+ """Set fan or fans to a fixed speed duty.
+
+ Valid channel values are 'fanN', where N >= 1 is the fan number, and
+ 'fan', to simultaneously configure all fans. Unconfigured fan channels
+ may default to 100% duty.
+ """
+ for hw_channel in self._get_hw_fan_channels(channel):
+ self._data.store(f'{hw_channel}_mode', _FanMode.FIXED_DUTY.value)
+ self._data.store(f'{hw_channel}_duty', duty)
+ self._send_set_cooling()
+
+ def set_speed_profile(self, channel, profile, **kwargs):
+ """Set fan or fans to follow a speed duty profile.
+
+ Valid channel values are 'fanN', where N >= 1 is the fan number, and
+ 'fan', to simultaneously configure all fans. Unconfigured fan channels
+ may default to 100% duty.
+
+ Up to seven (temperature, duty) pairs can be supplied in `profile`,
+ with temperatures in Celsius and duty values in percentage. The last
+ point should set the fan to 100% duty cycle, or be omitted; in the
+ latter case the fan will be set to max out at 60°C.
+ """
+ profile = list(profile)
+ for hw_channel in self._get_hw_fan_channels(channel):
+ self._data.store(f'{hw_channel}_mode', _FanMode.CUSTOM_PROFILE.value)
+ self._data.store(f'{hw_channel}_profile', profile)
+ self._send_set_cooling()
+
+ def _get_hw_fan_channels(self, channel):
+ channel = channel.lower()
+ if channel == 'fan':
+ return self._fan_names
+ if channel in self._fan_names:
+ return [channel]
+ raise ValueError(f'Unknown channel, should be one of: {_quoted("fan", *self._fan_names)}')
+
+ def _build_data_package(self, command, opCode, params=None):
+ if params:
+ buf = bytearray(3 + len(params))
+ buf[3 : 3 + len(params)] = params
+ else:
+ buf = bytearray(3)
+
+ buf[0] = next(self._sequence)
+ buf[1] = opCode
+ buf[2] = command
+
+ return buf
+
+ def _send_command(self, dataPackages):
+ buf = bytearray(_REPORT_LENGTH)
+
+ startIndex = 1
+ for dataPackage in dataPackages:
+ buf[startIndex : startIndex + len(dataPackage)] = dataPackage
+ startIndex += len(dataPackage)
+
+ buf[0] = startIndex - 1
+
+ LOGGER.debug('write %s', buf.hex())
+ self.device.clear_enqueued_reports()
+ self.device.write(buf)
+ buf = bytes(self.device.read(_REPORT_LENGTH))
+ self.device.release()
+ LOGGER.debug('received %s', buf.hex())
+ return buf
+
+ def _send_set_cooling(self):
+ for fan in self._fan_names:
+ fanIndex = 0
+ if fan == 'fan1':
+ fanIndex = 0
+ else:
+ fanIndex = 1
+
+ mode = _FanMode(self._data.load(f'{fan}_mode', of_type=int))
+
+ if mode is _FanMode.FIXED_DUTY:
+ dataPackages = list()
+ stored = self._data.load(f'{fan}_duty', of_type=int, default=100)
+ duty = clamp(stored, 0, 100)
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_SELECT, _OP_CODE_WRITE_ONE_BYTE, params=bytes([fanIndex])))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_MODE, _OP_CODE_WRITE_ONE_BYTE, params=bytes([mode.value])))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_FIXED_PWM, _OP_CODE_WRITE_ONE_BYTE, params=bytes([fraction_of_byte(percentage=duty)])))
+ LOGGER.info('setting %s to %d%% duty cycle', fan, duty)
+ self._send_command(dataPackages)
+
+ elif mode is _FanMode.CUSTOM_PROFILE:
+ stored = self._data.load(f'{fan}_profile', of_type=list, default=[])
+ profile = _prepare_profile(stored) # ensures correct len(profile)
+ pairs = ((temp, fraction_of_byte(percentage=duty)) for temp, duty in profile)
+
+ fanTemperatureData = list()
+ fanTemperatureData.append(0x0A) # 'magical' 0x0A in front of curve definition packages
+
+ fanDutyData = list()
+ fanDutyData.append(0x0A) # 'magical' 0x0A in front of curve definition packages
+
+ for temp, duty in profile:
+ fanTemperatureData.append(0x00)
+ fanTemperatureData.append(temp)
+ rpm = duty * _MAX_FAN_RPM / 100
+ fanDutyData.append(int(rpm % 255))
+ fanDutyData.append(int(rpm - (rpm % 255)) >> 8)
+
+ # Send temperature profile
+ self._send_command([self._build_data_package(_COMMAND_FAN_TEMP_TABLE, _OP_CODE_WRITE_THREE_BYTES, params=bytes(fanTemperatureData))])
+ # Send duty cycle Profile
+ self._send_command([self._build_data_package(_COMMAND_FAN_RPM_TABLE, _OP_CODE_WRITE_THREE_BYTES, params=bytes(fanDutyData))])
+
+ # Change mode to custom Profile
+ dataPackages = list()
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_SELECT, _OP_CODE_WRITE_ONE_BYTE, params=bytes([fanIndex])))
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_MODE, _OP_CODE_WRITE_ONE_BYTE, params=bytes([mode.value])))
+ self._send_command(dataPackages)
+
+ LOGGER.info('setting %s to follow profile %r', fan, profile)
+ else:
+ raise ValueError(f'Unsupported fan {mode}')
+
+ pump_mode = _PumpMode(self._data.load('pump_mode', of_type=int))
+
+ dataPackages = list()
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_SELECT, _OP_CODE_WRITE_ONE_BYTE, params=bytes([_PUMP_INDEX])))
+ if pump_mode == _PumpMode.QUIET:
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_FIXED_RPM, _OP_CODE_WRITE_TWO_BYTES, params=bytes(_PUMP_DEFAULT_QUIET)))
+ elif pump_mode == _PumpMode.EXTREME:
+ dataPackages.append(self._build_data_package(_COMMAND_FAN_FIXED_RPM, _OP_CODE_WRITE_TWO_BYTES, params=bytes(_PUMP_DEFAULT_EXTREME)))
+ self._send_command(dataPackages)
+
+ LOGGER.info('setting pump mode to %s', pump_mode.name.lower())
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment