Created
September 28, 2023 16:29
-
-
Save jsb2505/317f82dee2b5eafd1cac3ebc5eddba72 to your computer and use it in GitHub Desktop.
A gist of formwork formulas from CIRIA 108: Derivation of Concrete Pressure in Formwork
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
/**Temperature coefficient based on CIRIA 108 - Derivation of Concrete Pressure in Formwork | |
*/ | |
Get_Temperature_Coefficient_K = LAMBDA(concrete_temp_at_placing, | |
LET( | |
T, concrete_temp_at_placing, | |
(36 / (T + 16))^2 | |
) | |
); | |
/**Max design pressure of concrete in formwork based on CIRIA 108 - Derivation of Concrete Pressure in Formwork | |
*/ | |
Get_Max_Design_Pressure = LAMBDA(formwork_coefficient, concrete_coefficient, concrete_density, formwork_height, pour_height, concrete_temp_at_placing, rate_concrete_rise, | |
LET( | |
C_1, formwork_coefficient, | |
C_2, concrete_coefficient, | |
D, concrete_density, | |
h_formwork, formwork_height, | |
h_pour, pour_height, | |
T, concrete_temp_at_placing, | |
R, rate_concrete_rise, | |
K, Get_Temperature_Coefficient_K(T), | |
IF( | |
C_1 * SQRT(R) > h_formwork, | |
D * h_pour, | |
MIN( | |
D * h_pour, | |
D * (C_1 * SQRT(R) + C_2 * K * SQRT(h_formwork - C_1 * SQRT(R))) | |
) | |
) | |
) | |
); | |
/**Rate of concrete rise uniformly based on CIRIA 108 - Derivation of Concrete Pressure in Formwork | |
*/ | |
Get_Rate_of_Rise_Uniform = LAMBDA(pumping_rate, length_of_wall, thickness_of_wall, | |
pumping_rate / (length_of_wall * thickness_of_wall) | |
); |