#!/usr/bin/python | |
# script to poll growatt PV inverter and spit out values | |
# Andrew Elwell <[email protected]> 2013-09-01 | |
import ConfigParser | |
from pymodbus.client.sync import ModbusSerialClient as ModbusClient | |
import time | |
import mosquitto | |
config = "/home/andrew/solarmon.cfg" | |
settings = ConfigParser.RawConfigParser() | |
settings.read(config) | |
port = settings.get('inverter', 'port') | |
result = {} | |
result['timestamp'] = time.time() | |
client = ModbusClient(method='rtu', port=port, baudrate=9600, stopbits=1, parity='N', bytesize=8, timeout=1) | |
client.connect() | |
broker = settings.get('mosquitto', 'broker') | |
mqtt = mosquitto.Mosquitto("PV_Monitor") | |
mqtt.connect(broker) | |
mqtt.loop_start() | |
# can't read the whole lot in one pass, so grab each chunk | |
# addr / descriptions lifted from http://code.google.com/p/pvbeancounter/source/browse/trunk_v2/PVSettings/Device_Growatt.xml | |
rr = client.read_input_registers(2,3) | |
mqtt.publish("PV_W", rr.registers[0]) | |
mqtt.publish("PV_V", rr.registers[1]) | |
mqtt.publish("PV_A", rr.registers[2]) | |
rr = client.read_input_registers(12,3) | |
mqtt.publish("Out_W", rr.registers[0]) | |
mqtt.publish("AC_Hz", rr.registers[1]) | |
mqtt.publish("AC_V", rr.registers[2]) | |
rr = client.read_input_registers(27, 1) | |
mqtt.publish("kWh_today", rr.registers[0]) | |
rr = [] | |
rr = client.read_input_registers(29,1) | |
mqtt.publish("kWh_total", rr.registers[0]) | |
client.close() | |
mqtt.loop_stop() | |
mqtt.disconnect() |