HomeAssistant Modbus configuration for Pichler LG350 Ventilation Units (possible for LG450 too)
modbus:
- name: pichlerlg350
type: tcp
host: 192.168.44.232
port: 502
delay: 2
message_wait_milliseconds: 30
binary_sensors:
- name: "lg350_bypassklappe" # 0.0
unique_id: "lg350_bypassklappe"
slave: 20
address: 20
input_type: input
device_class: opening
switches:
- name: "lg350_betriebsmodus_sommer"
slave: 20
address: 1
write_type: holding
command_on: 1 # Sommer
command_off: 2 # Winter
verify:
delay: 1
- name: "lg350_bypassklappe_force_open"
slave: 20
address: 49
write_type: holding
# data_type: uint16
command_on: 2 # Ein/Offen
command_off: 0 # Normal. "1" waere Aus/Geschlossen
verify:
delay: 1
sensors:
- name: "lg350_temp_aussenluft" # 0.0
unique_id: "lg350_temp_aussenluft"
unit_of_measurement: "°C"
slave: 20
address: 30
input_type: input
data_type: int16
offset: -100
precision: 1
scale: 0.1
- name: "lg350_temp_fortluft" # 3.0
unique_id: "lg350_temp_fortluft"
unit_of_measurement: "°C"
slave: 20
address: 31 # 30
input_type: input
data_type: int16
offset: -100
precision: 1
scale: 0.1
- name: "lg350_temp_abluft" # 0.2
unique_id: "lg350_temp_abluft"
unit_of_measurement: "°C"
slave: 20
address: 32 # 31
input_type: input
data_type: int16
offset: -100
precision: 1
scale: 0.1
- name: "lg350_temp_zuluft" # xxx
unique_id: "lg350_temp_zuluft"
unit_of_measurement: "°C"
slave: 20
address: 33 # 32
input_type: input
data_type: int16
offset: -100
precision: 1
scale: 0.1
- name: "lg350_temp_aussenluft_vhr"
unique_id: "lg350_temp_aussenluft_vhr"
unit_of_measurement: "°C"
slave: 20
address: 34
input_type: input
data_type: int16
offset: -100
precision: 1
scale: 0.1
- name: "lg350_zuluftdrehzahl"
unique_id: "lg350_zuluftdrehzahl"
unit_of_measurement: "rpm"
slave: 20
address: 39
input_type: input
data_type: int16
- name: "lg350_abluftdrehzahl"
unique_id: "lg350_abluftdrehzahl"
unit_of_measurement: "rpm"
slave: 20
address: 40
input_type: input
data_type: int16
- name: "lg350_zuluftstrom"
unique_id: "lg350_zuluftstrom"
unit_of_measurement: "m3/h"
slave: 20
address: 46
input_type: input
data_type: int16
- name: "lg350_abluftstrom"
unique_id: "lg350_abluftstrom"
unit_of_measurement: "m3/h"
slave: 20
address: 47
input_type: input
data_type: int16
- name: "lg350_reststandzeit_filter"
unique_id: "lg350_reststandzeit_filter"
unit_of_measurement: "h"
slave: 20
address: 50
input_type: input
data_type: uint16
- name: "lg350_betriebsmodus_sw"
unique_id: "lg350_betriebsmodus_sw"
slave: 20
address: 1
input_type: holding
data_type: uint16
- name: "lg350_lufstrom_stufe1"
unique_id: "lg350_luftstrom_stufe1"
unit_of_measurement: "m3/h"
slave: 20
address: 9
input_type: holding
data_type: int16
- name: "lg350_lufstrom_stufe2"
unique_id: "lg350_luftstrom_stufe2"
unit_of_measurement: "m3/h"
slave: 20
address: 10
input_type: holding
data_type: int16
- name: "lg350_lufstrom_stufe3"
unique_id: "lg350_luftstrom_stufe3"
unit_of_measurement: "m3/h"
slave: 20
address: 11
input_type: holding
data_type: int16
- name: "lg350_luftstufe"
unique_id: "lg350_luftstufe"
slave: 20
address: 2
input_type: holding
data_type: int16
- name: "lg350_bypassklappe_set"
unique_id: "lg350_bypassklappe_set"
slave: 20
address: 49
input_type: holding
data_type: int16
- name: "lg350_abluftdifferenz_stufe1"
unique_id: "lg350_abluftdifferenz_stufe1"
unit_of_measurement: "m3/h"
slave: 20
address: 83
input_type: holding
data_type: int16
offset: -500
- name: "lg350_abluftdifferenz_stufe2"
unique_id: "lg350_abluftdifferenz_stufe2"
unit_of_measurement: "m3/h"
slave: 20
address: 84
input_type: holding
data_type: int16
offset: -500
- name: "lg350_abluftdifferenz_stufe3"
unique_id: "lg350_abluftdifferenz_stufe3"
unit_of_measurement: "m3/h"
slave: 20
address: 85
input_type: holding
data_type: int16
offset: -500
sensor:
- platform: template
sensors:
lg350_luftstufe_render:
friendly_name: "Luftstufe"
value_template: >-
{% set lg350_luftstufe_mapper = {
0: 'Standby',
1: 'Stufe 1',
2: 'Stufe 2',
3: 'Stufe 3',
4: 'Grundlüftung'} %}
{% set state = states('sensor.lg350_luftstufe')|int %}
{{ lg350_luftstufe_mapper[state] if state in lg350_luftstufe_mapper else 'Unknown' }}
lg350_bypassklappe_set_render:
friendly_name: "Bypass Klappe Stellung"
value_template: >-
{% set lg350_bypassklappe_set_mapper = {
0: 'Normal',
1: 'Aus/Geschlossen',
2: 'Ein/Offen'} %}
{% set state = states('sensor.lg350_bypassklappe_set')|int %}
{{ lg350_bypassklappe_set_mapper[state] if state in lg350_bypassklappe_set_mapper else 'Unknown' }}
lg350_betriebsmodus_sw_render:
friendly_name: "Betriebsmodus"
value_template: >-
{% set lg350_betriebsmodus_sw_mapper = {
1: 'Sommer',
2: 'Winter'} %}
{% set state = states('sensor.lg350_betriebsmodus_sw')|int %}
{{ lg350_betriebsmodus_sw_mapper[state] if state in lg350_betriebsmodus_sw_mapper else 'Unknown' }}
template:
- sensor:
- name: "LG350 Heizleistung"
unique_id: "lg350_heizleistung"
state_class: "measurement"
unit_of_measurement: "W"
device_class: power
state: >
{% set vorlauf = states('sensor.lg350_temp_zuluft') | float (0) %}
{% set ruecklauf = states('sensor.lg350_temp_abluft') | float %}
{% set durchfluss = states('sensor.lg350_zuluftstrom') | float %}
{{ ((vorlauf - ruecklauf) * durchfluss * 0.33 ) | round(1, default=0) }}
@silenthunter99
Copy link

Hello guys,
excuse me if it is a dumb question, First time doing something with Modbus RTU-> TCP and not too long in HA

Has anyone an idea why i can´t set any settings at the ventilation unit?
I have the same device Elfin EE11A as [mihu-ov].

Can´t seem to find the right setting for this

Elfin1 Elfin2

Elfin3`

Elfin seems to communicate with the HA instance

HA:
HA1

HA2 Sensor readings work

Thanks

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment