sensor: | |
# These should be used in the energy dashboard. | |
- platform: integration | |
source: sensor.shp_circuit_1_power | |
name: SHP Circuit 1 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_2_power | |
name: SHP Circuit 2 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_3_power | |
name: SHP Circuit 3 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_4_power | |
name: SHP Circuit 4 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_5_power | |
name: SHP Circuit 5 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_6_power | |
name: SHP Circuit 6 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_7_power | |
name: SHP Circuit 7 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
method: left | |
- platform: integration | |
source: sensor.shp_circuit_8_power | |
name: SHP Circuit 8 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_9_power | |
name: SHP Circuit 9 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
- platform: integration | |
source: sensor.shp_circuit_10_power | |
name: SHP Circuit 10 Consumed Energy | |
unit_prefix: k | |
round: 3 | |
template: | |
- sensor: | |
- name: "ECOFLOW Smart Home Panel Combined Circuit Power" | |
unit_of_measurement: "kW" | |
device_class: power | |
state_class: measurement | |
state: >- | |
{{ ((states.sensor | |
| selectattr('entity_id', 'search', 'sensor.shp_') | |
| rejectattr('entity_id', 'search', 'delta_pro') | |
| selectattr('entity_id', 'search', '_power$') | |
| map(attribute='state') | map('float') | sum) / 1000) | round(2) | |
}} | |
- select: | |
- name: "SHP Circuit 1 Mode" | |
unique_id: shp_circuit_1_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_1_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_1_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_1_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":0,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":0,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":0,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":0,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 2 Mode" | |
unique_id: shp_circuit_2_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_2_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_2_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_2_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":1,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":1,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":1,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":1,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 3 Mode" | |
unique_id: shp_circuit_3_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_3_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_3_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_3_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":2,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":2,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":2,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":2,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 4 Mode" | |
unique_id: shp_circuit_4_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_4_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_4_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_4_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":3,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":3,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":3,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":3,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 5 Mode" | |
unique_id: shp_circuit_5_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_5_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_5_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_5_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":4,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":4,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":4,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":4,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 6 Mode" | |
unique_id: shp_circuit_6_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_6_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_6_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_6_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":5,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":5,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":5,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":5,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 7 Mode" | |
unique_id: shp_circuit_7_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_7_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_7_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_7_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":6,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":6,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":6,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":6,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 8 Mode" | |
unique_id: shp_circuit_8_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_8_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_8_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_8_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":7,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":7,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":7,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":7,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 9 Mode" | |
unique_id: shp_circuit_9_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_9_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_9_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_9_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":8,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":8,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":8,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":8,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- name: "SHP Circuit 10 Mode" | |
unique_id: shp_circuit_10_mode | |
state: >- | |
{% if is_state('binary_sensor.shp_circuit_10_auto','on') %}Auto | |
{% else %} | |
{% set i = int(states('sensor.shp_circuit_10_state')) %} | |
{% set o = {0:'Grid',1:'Battery',2:'Off'} %} | |
{{ o[i] if i in o.keys() }} | |
{% endif %} | |
options: "{{ ['Auto','Grid','Battery','Off'] }}" | |
icon: >- | |
{% set i = int(states('sensor.shp_circuit_10_state')) %} | |
{% set o = {0:'mdi:home-lightning-bolt-outline',1:'mdi:home-battery-outline',2:'mdi:home-off-outline'} %} | |
{{ o[i] if i in o.keys() }} | |
select_option: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: >- | |
{% set i = option %} | |
{% set p = '{"from":"HA","id":"' %} | |
{% set s = '","moduleType":0,"operateType":"TCP","params":' %} | |
{% set id = 999900000+(range(10000,99999)|random) %} | |
{% set o = { | |
'Auto':'{"sta":0,"ctrlMode":0,"ch":9,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Grid':'{"sta":0,"ctrlMode":1,"ch":9,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Battery':'{"sta":1,"ctrlMode":1,"ch":9,"cmdSet":11,"id":16},"version":"1.0"}', | |
'Off':'{"sta":2,"ctrlMode":1,"ch":9,"cmdSet":11,"id":16},"version":"1.0"}' | |
} | |
%} | |
{% if i in o.keys() %}{{p}}{{id}}{{s}}{{o[i]}}{% endif %} | |
- number: | |
- name: "SHP - Charge Limit" | |
unique_id: shp_charge_limit | |
state: "{{ states('sensor.shp_battery_charge_level') }}" | |
icon: mdi:battery-arrow-up | |
min: "50" | |
max: "100" | |
step: "1" | |
set_value: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"discLower":{{states("number.shp_discharge_limit")}},"forceChargeHigh":{{value}},"cmdSet":11,"id":29},"version":"1.0"}' | |
- name: "SHP - Discharge Limit" | |
unique_id: shp_discharge_limit | |
state: "{{ states('sensor.shp_battery_discharge_level') }}" | |
icon: mdi:battery-arrow-down-outline | |
min: "0" | |
max: "30" | |
step: "1" | |
set_value: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"discLower":{{value}},"forceChargeHigh":{{states("number.shp_charge_limit")}},"cmdSet":11,"id":29},"version":"1.0"}' | |
mqtt: | |
binary_sensor: | |
- name: SHP Grid Available | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: connectivity | |
payload_on: "1" | |
payload_off: "0" | |
value_template: "{{ value_json.params.gridSta if value_json['params']['id'] == 2 else states('sensor.shp_grid_available') }}" | |
- name: SHP Delta Pro 1 Connected | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: connectivity | |
payload_on: "1" | |
payload_off: "0" | |
value_template: "{{ value_json.params.energyInfos[0].stateBean.isConnect if value_json['params']['id'] == 2 else states('sensor.shp_delta_pro_1_connected') }}" | |
- name: SHP Delta Pro 1 Enabled | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: connectivity | |
payload_on: "1" | |
payload_off: "0" | |
value_template: "{{ value_json.params.energyInfos[0].stateBean.isEnable if value_json['params']['id'] == 2 else states('sensor.shp_delta_pro_1_enabled') }}" | |
- name: SHP Delta Pro 2 Connected | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: connectivity | |
payload_on: "1" | |
payload_off: "0" | |
value_template: "{{ value_json.params.energyInfos[1].stateBean.isConnect if value_json['params']['id'] == 2 else states('sensor.shp_delta_pro_2_connected') }}" | |
- name: SHP Delta Pro 2 Enabled | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: connectivity | |
payload_on: "1" | |
payload_off: "0" | |
value_template: "{{ value_json.params.energyInfos[1].stateBean.isEnable if value_json['params']['id'] == 2 else states('sensor.shp_delta_pro_2_enabled') }}" | |
- name: SHP AC1 Grid Charging | |
object_id: shp_ac1_grid_charging | |
unique_id: shp_ac1_grid_charging | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "1" | |
payload_off: "0" | |
qos: 0 | |
value_template: "{{ value_json.params.energyInfos[0].stateBean.isGridCharge if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP AC2 Grid Charging | |
object_id: shp_ac2_grid_charging | |
unique_id: shp_ac2_grid_charging | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "1" | |
payload_off: "0" | |
qos: 0 | |
value_template: "{{ value_json.params.energyInfos[1].stateBean.isGridCharge if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP EPS Enabled | |
object_id: shp_eps_enabled | |
unique_id: shp_eps_enabled | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "1" | |
payload_off: "0" | |
qos: 0 | |
value_template: "{{ value_json.params.eps if value_json['params']['id'] == 25 else this.state }}" | |
# Mode of the circuit/control | |
- name: SHP Circuit 1 Auto | |
object_id: shp_circuit_1_auto | |
unique_id: shp_circuit_1_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[0].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 2 Auto | |
object_id: shp_circuit_2_auto | |
unique_id: shp_circuit_2_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[1].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 3 Auto | |
object_id: shp_circuit_3_auto | |
unique_id: shp_circuit_3_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[2].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 4 Auto | |
object_id: shp_circuit_4_auto | |
unique_id: shp_circuit_4_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[3].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 5 Auto | |
object_id: shp_circuit_5_auto | |
unique_id: shp_circuit_5_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[4].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 6 Auto | |
object_id: shp_circuit_6_auto | |
unique_id: shp_circuit_6_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[5].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 7 Auto | |
object_id: shp_circuit_7_auto | |
unique_id: shp_circuit_7_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[6].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 8 Auto | |
object_id: shp_circuit_8_auto | |
unique_id: shp_circuit_8_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[7].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 9 Auto | |
object_id: shp_circuit_9_auto | |
unique_id: shp_circuit_9_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[8].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 10 Auto | |
object_id: shp_circuit_10_auto | |
unique_id: shp_circuit_10_auto | |
state_topic: "ecoflow/SHP/data" | |
payload_on: "0" | |
payload_off: "1" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[9].ctrlMode if value_json['params']['id'] == 2 else this.state }}" | |
sensor: | |
# Don't use these in the energy dashboard, irregular spikes cause inaccurate readings. | |
- name: SHP Circuit 1 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[0] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_1_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_1_energy', 'last_reset') }}" | |
- name: SHP Circuit 2 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[1] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_2_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_2_energy', 'last_reset') }}" | |
- name: SHP Circuit 3 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[2] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_3_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_3_energy', 'last_reset') }}" | |
- name: SHP Circuit 4 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[3] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_4_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_4_energy', 'last_reset') }}" | |
- name: SHP Circuit 5 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[4] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_5_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_5_energy', 'last_reset') }}" | |
- name: SHP Circuit 6 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[5] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_6_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_6_energy', 'last_reset') }}" | |
- name: SHP Circuit 7 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[6] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_7_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_7_energy', 'last_reset') }}" | |
- name: SHP Circuit 8 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[7] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_8_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_8_energy', 'last_reset') }}" | |
- name: SHP Circuit 9 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[8] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_9_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_9_energy', 'last_reset') }}" | |
- name: SHP Circuit 10 Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[9] | sum | round(0) if value_json['params']['id'] == 48 else states('sensor.shp_circuit_10_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 48 else state_attr('sensor.shp_circuit_10_energy', 'last_reset') }}" | |
# Smart Home Panel Power Demand | |
- name: SHP Circuit 1 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[0].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_1_power') }}" | |
#force_update: true | |
- name: SHP Circuit 2 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[1].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_2_power') }}" | |
#force_update: true | |
- name: SHP Circuit 3 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[2].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_3_power') }}" | |
#force_update: true | |
- name: SHP Circuit 4 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[3].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_4_power') }}" | |
#force_update: true | |
- name: SHP Circuit 5 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[4].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_5_power') }}" | |
#force_update: true | |
- name: SHP Circuit 6 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[5].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_6_power') }}" | |
#force_update: true | |
- name: SHP Circuit 7 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[6].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_7_power') }}" | |
#force_update: true | |
- name: SHP Circuit 8 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[7].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_8_power') }}" | |
#force_update: true | |
- name: SHP Circuit 9 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[8].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_9_power') }}" | |
#force_update: true | |
- name: SHP Circuit 10 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[9].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_circuit_10_power') }}" | |
#force_update: true | |
- name: SHP Delta Pro 1 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[10].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_delta_pro_1_power') }}" | |
json_attributes_topic: "ecoflow/SHP/data" | |
json_attributes_template: "{{ value_json.params.infoList[10] | tojson if value_json['params']['id'] == 96 else (states.sensor.shp_delta_pro_1_power.attributes | tojson) }}" | |
#force_update: true | |
- name: SHP Delta Pro 2 Power | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: power | |
unit_of_measurement: "W" | |
state_class: measurement | |
value_template: "{{ value_json.params.infoList[11].chWatt | round(0) if value_json['params']['id'] == 96 else states('sensor.shp_delta_pro_2_power') }}" | |
json_attributes_topic: "ecoflow/SHP/data" | |
json_attributes_template: "{{ value_json.params.infoList[11] | tojson if value_json['params']['id'] == 96 else (states.sensor.shp_delta_pro_2_power.attributes | tojson) }}" | |
#force_update: true | |
- name: SHP Circuit 1 State | |
object_id: shp_circuit_1_state | |
unique_id: shp_circuit_1_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[0].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 2 State | |
object_id: shp_circuit_2_state | |
unique_id: shp_circuit_2_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[1].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 3 State | |
object_id: shp_circuit_3_state | |
unique_id: shp_circuit_3_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[2].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 4 State | |
object_id: shp_circuit_4_state | |
unique_id: shp_circuit_4_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[3].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 5 State | |
object_id: shp_circuit_5_state | |
unique_id: shp_circuit_5_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[4].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 6 State | |
object_id: shp_circuit_6_state | |
unique_id: shp_circuit_6_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[5].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 7 State | |
object_id: shp_circuit_7_state | |
unique_id: shp_circuit_7_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[6].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 8 State | |
object_id: shp_circuit_8_state | |
unique_id: shp_circuit_8_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[7].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 9 State | |
object_id: shp_circuit_9_state | |
unique_id: shp_circuit_9_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[8].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP Circuit 10 State | |
object_id: shp_circuit_10_state | |
unique_id: shp_circuit_10_state | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
value_template: "{{ value_json.params.loadCmdChCtrlInfos[9].ctrlSta if value_json['params']['id'] == 2 else this.state }}" | |
- name: SHP AC1 Battery Percentage | |
state_topic: "ecoflow/SHP/data" | |
unique_id: shp_ac1_battery_percentage | |
qos: 0 | |
device_class: battery | |
unit_of_measurement: "%" | |
state_class: measurement | |
value_template: "{{ value_json.params.energyInfos[0].batteryPercentage | round(0) if value_json['params']['id'] == 2 else states('sensor.shp_ac1_battery_percentage') }}" | |
availability: | |
- topic: "ecoflow/SHP/data" | |
payload_available: "1" | |
payload_not_available: "0" | |
value_template: "{{ value_json.params.energyInfos[0].stateBean.isEnable if value_json['params']['id'] == 2 else states('sensor.shp_delta_pro_1_enabled') }}" | |
- name: SHP AC2 Battery Percentage | |
state_topic: "ecoflow/SHP/data" | |
unique_id: shp_ac2_battery_percentage | |
qos: 0 | |
device_class: battery | |
unit_of_measurement: "%" | |
state_class: measurement | |
value_template: "{{ value_json.params.energyInfos[1].batteryPercentage | round(0) if value_json['params']['id'] == 2 else states('sensor.shp_ac2_battery_percentage') }}" | |
availability: | |
- topic: "ecoflow/SHP/data" | |
payload_available: "1" | |
payload_not_available: "0" | |
value_template: "{{ value_json.params.energyInfos[1].stateBean.isEnable if value_json['params']['id'] == 2 else states('sensor.shp_delta_pro_2_enabled') }}" | |
- name: SHP Battery Charge Level | |
object_id: shp_battery_charge_level | |
unique_id: shp_battery_charge_level | |
unit_of_measurement: "%" | |
device_class: battery | |
state_class: measurement | |
state_topic: "ecoflow/SHP/data/limits" | |
qos: 0 | |
value_template: "{{ value_json.params.forceChargeHigh if value_json['params']['id'] == 30 else this.state }}" | |
- name: SHP Battery Discharge Level | |
object_id: shp_battery_discharge_level | |
unique_id: shp_battery_discharge_level | |
unit_of_measurement: "%" | |
device_class: battery | |
state_class: measurement | |
state_topic: "ecoflow/SHP/data/limits" | |
qos: 0 | |
value_template: "{{ value_json.params.discLower if value_json['params']['id'] == 30 else this.state }}" | |
- name: SHP Circuit 1 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[0] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_1_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_1_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 2 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[1] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_2_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_2_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 3 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[2] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_3_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_3_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 4 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[3] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_4_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_4_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 5 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[4] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_5_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_5_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 6 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[5] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_6_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_6_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 7 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[6] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_7_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_7_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 8 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[7] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_8_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_8_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 9 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[8] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_9_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_9_battery_energy', 'last_reset') }}" | |
- name: SHP Circuit 10 Battery Energy | |
state_topic: "ecoflow/SHP/data" | |
qos: 0 | |
device_class: energy | |
unit_of_measurement: "Wh" | |
state_class: total | |
value_template: "{{ value_json.params.watth[9] | sum | round(0) if value_json['params']['id'] == 49 else states('sensor.shp_circuit_10_battery_energy') }}" | |
last_reset_value_template: "{{ (as_timestamp(strptime(value_json.params.rtc, '%Y-%m-%d')) | as_datetime()).isoformat() if value_json['params']['id'] == 49 else state_attr('sensor.shp_circuit_10_battery_energy', 'last_reset') }}" | |
switch: | |
- platform: template | |
switches: | |
shp_eps: | |
friendly_name: "SHP EPS" | |
value_template: "{{ states('binary_sensor.shp_eps_enabled') }}" | |
turn_on: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"cmdSet":11,"id":24,"eps":1},"version":"1.0"}' | |
turn_off: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"cmdSet":11,"id":24,"eps":0},"version":"1.0"}' | |
icon_template: >- | |
{% if is_state('binary_sensor.shp_eps_enabled','on') %} | |
mdi:speedometer | |
{% else %} | |
mdi:speedometer-slow | |
{% endif %} | |
shp_pro1_recharge: | |
friendly_name: "SHP AC1 Recharge" | |
value_template: "{{ states('binary_sensor.shp_ac1_grid_charging') }}" | |
turn_on: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"sta":2,"ctrlMode":1,"ch":10,"cmdSet":11,"id":17},"version":"1.0"}' | |
turn_off: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"sta":0,"ctrlMode":0,"ch":10,"cmdSet":11,"id":17},"version":"1.0"}' | |
icon_template: >- | |
{% if is_state('binary_sensor.shp_ac1_grid_charging','on') %} | |
mdi:battery-charging | |
{% else %} | |
mdi:battery | |
{% endif %} | |
shp_pro2_recharge: | |
friendly_name: "SHP AC2 Recharge" | |
value_template: "{{ states('binary_sensor.shp_ac2_grid_charging') }}" | |
turn_on: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"sta":2,"ctrlMode":1,"ch":11,"cmdSet":11,"id":17},"version":"1.0"}' | |
turn_off: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/set | |
payload: '{"from":"HA","id":"{{999900000+(range(10000,99999)|random)}}","moduleType":0,"operateType":"TCP","params":{"sta":0,"ctrlMode":0,"ch":11,"cmdSet":11,"id":17},"version":"1.0"}' | |
icon_template: >- | |
{% if is_state('binary_sensor.shp_ac2_grid_charging','on') %} | |
mdi:battery-charging | |
{% else %} | |
mdi:battery | |
{% endif %} | |
automation: | |
- id: "EF_SHP_Limits" | |
alias: SHP - Limits | |
description: "Re-Publish SHP Charge/Discharge Limits to new Topic" | |
trigger: | |
- platform: mqtt | |
topic: ecoflow/SHP/data | |
payload: "30" | |
value_template: "{{ value_json.params['id'] }}" | |
condition: [] | |
action: | |
- service: mqtt.publish | |
data: | |
topic: ecoflow/SHP/data/limits | |
payload: "{{trigger.payload}}" | |
retain: true | |
mode: single |
Thank you very much. I corrected the code but still get this - "Bad socket read/write on client local.PIETER-SHP: A TLS error occurred". This is what I have in the line : remote_clientid PIETER-SHP. Does this need to be in a different format or match any details in HA? Do I need certificate enabled in the MQTT broker configuration settings?
Update: After checking your example code above, I can see that you are connecting bridge over 8883 but my broker is trying to connect over 1883. Could you advise on where I need to update this?
2024-09-09 14:36:22: Connecting bridge ecoflow-bridge (mqtt-e.ecoflow.com:1883)
Sorted: missed the port in the config line!!doh!
Any idea on if i can control AC1 or AC2 charging from HA?
You should have switches declared in your YAML. Don't forget that the YAML above is slightly outdated and you need to refer to the YAML in this gist instead: https://gist.github.com/lwsrbrts/50d6c8168fab3360e8619ec31aad422a
The YAML does declare the switches and mine in my dashboard are derived from that, so it should be OK. May be wise to check your HA logs in Settings > System > Logs and see if you have any errors relating to the switches there.
Cheers @lwsrbrts ! Just me being to hasty and after digging through the entities, I found them. I have an old school grid tied solar setup that's isolated from my Smart home panel setup and DP's. Now i can setup automation to charge the batteries through the ac1&2 ports when my Fronius inverter hits 1000w from the solar setup so in essence indirectly charging the batteries from solar :) Thank you very much for all the help and details provided and for a non developer, I could get this all sorted with some YouTube videos and multiple trial and error nights :)
I assume you've added the curly braces everywhere? Just confirming but there shouldn't be any curly braces in your
mosquitto.conf
file at all.My use of
{token}
shows that as something you'd replace with your own data/info/username/password etc. Replace everything, including the curly brackets.