ventilation_cfm = 5 | |
minutes = 60 | |
room_volume_cu_ft = 140 | |
# this is for a human at rest. | |
o2_to_co2_cu_ft_per_minute = 0.009*2 | |
# starting/natural conditions -- typical | |
# see http://www.molecularproducts.com/pdf/technical-library/A%20Guide%20to%20Breathing%20Rates%20in%20Confined%20Environments%20Technical%20Article.pdf | |
co2_percent_start = 0.000314 | |
o2_percent_start = 0.2095 | |
co2_cu_ft = room_volume_cu_ft * co2_percent_start | |
o2_cu_ft = room_volume_cu_ft * o2_percent_start | |
co2_percent = co2_percent_start | |
o2_percent = o2_percent_start | |
for i in range(minutes): # step through each minute | |
# account for respiration of one person | |
co2_cu_ft += o2_to_co2_cu_ft_per_minute | |
o2_cu_ft -= o2_to_co2_cu_ft_per_minute | |
# account for natural exfiltration | |
co2_cu_ft -= ventilation_cfm * co2_percent | |
o2_cu_ft -= ventilation_cfm * o2_percent | |
# account for natural infiltration | |
co2_cu_ft += ventilation_cfm * co2_percent_start | |
o2_cu_ft += ventilation_cfm * o2_percent_start | |
co2_percent = co2_cu_ft / room_volume_cu_ft | |
o2_percent = o2_cu_ft / room_volume_cu_ft | |
co2_ppm = int(co2_percent * 1000000) | |
print("{} minutes: {:0.2f}% O2; {}PPM CO2".format(i+1, o2_percent*100, co2_ppm)) |