esphome: |
|
name: linky |
|
|
|
# https://esphome.io/components/esp8266.html |
|
esp8266: |
|
board: d1_mini |
|
|
|
# https://esphome.io/components/esp32.html |
|
#esp32: |
|
# board: lolin_s2_mini |
|
# variant: esp32s2 |
|
|
|
# WiFi Component: https://esphome.io/components/wifi.html |
|
wifi: |
|
ssid: !secret esphome_wifi_ssid |
|
password: !secret esphome_wifi_password |
|
manual_ip: |
|
static_ip: 192.168.125.84 |
|
gateway: 192.168.125.1 |
|
subnet: 255.255.255.0 |
|
dns1: 192.168.125.1 |
|
ap: |
|
ssid: Linky |
|
password: !secret esphome_wifi_password |
|
|
|
# OTA Update Component: https://esphome.io/components/ota.html |
|
ota: |
|
password: !secret esphome_ota_password |
|
|
|
# Logger Component: https://esphome.io/components/logger.html |
|
logger: |
|
baud_rate: 0 # disable logging via UART, help to avoid numerous crash with ESP_LOGD |
|
hardware_uart : UART1 |
|
level: info |
|
esp8266_store_log_strings_in_flash: false |
|
|
|
# Native API Component: https://esphome.io/components/api.html |
|
api: |
|
encryption: |
|
key: imB+N0VsxE6Ape4RhsxuyDLjCkeDIHl0GNyj1Gm3ylU= |
|
|
|
# Captive Portal: https://esphome.io/components/captive_portal.html |
|
captive_portal: |
|
|
|
# Web Server: https://esphome.io/components/web_server.html |
|
web_server: |
|
local: true |
|
port: 80 |
|
auth: |
|
username: !secret esphome_web_server_username |
|
password: !secret esphome_web_server_password |
|
|
|
# Time: https://esphome.io/components/time.html |
|
time: |
|
- platform: homeassistant |
|
timezone: "Europe/Paris" |
|
id: homeassistant_time |
|
|
|
# Status Binary Sensor: https://esphome.io/components/binary_sensor/status.html |
|
binary_sensor: |
|
- platform: status |
|
name: "Linky Status" |
|
|
|
# Restart Button: https://esphome.io/components/button/restart.html |
|
button: |
|
- platform: restart |
|
name: "Linky Restart" |
|
|
|
# https://esphome.io/custom/uart.html |
|
uart: |
|
id: uart_bus |
|
rx_pin: GPIO3 |
|
baud_rate: 9600 # 9600 == mode standard, 1200 == mode historique |
|
parity: EVEN |
|
data_bits: 7 |
|
stop_bits: 1 |
|
|
|
# https://esphome.io/components/sensor/teleinfo.html |
|
teleinfo: |
|
update_interval: 5s |
|
historical_mode: false # false == mode standard, true == mode historique |
|
|
|
# https://esphome.io/components/sensor/index.html |
|
sensor: |
|
# WiFi |
|
- platform: wifi_signal |
|
name: "Linky WiFi Signal" |
|
unit_of_measurement: dB |
|
device_class: signal_strength |
|
accuracy_decimals: 0 |
|
update_interval: 60s |
|
# Uptime |
|
- platform: uptime |
|
name: "Linky Uptime" |
|
unit_of_measurement: s |
|
device_class: duration |
|
accuracy_decimals: 0 |
|
update_interval: 60s |
|
#-------------- |
|
# MODE STANDARD |
|
#-------------- |
|
# Énergie active soutirée totale |
|
- platform: teleinfo |
|
tag_name: "EAST" |
|
name: "Linky Energie Soutirée" |
|
unit_of_measurement: kWh |
|
device_class: energy |
|
state_class: total_increasing |
|
accuracy_decimals: 3 |
|
filters: |
|
- multiply: 0.001 |
|
# Energie active soutirée Fournisseur, index 01 |
|
- platform: teleinfo |
|
tag_name: "EASF01" |
|
name: "Linky Energie Soutirée Tempo Bleu HC" |
|
unit_of_measurement: kWh |
|
device_class: energy |
|
state_class: total_increasing |
|
accuracy_decimals: 3 |
|
filters: |
|
- multiply: 0.001 |
|
# Energie active soutirée Fournisseur, index 02 |
|
- platform: teleinfo |
|
tag_name: "EASF02" |
|
name: "Linky Energie Soutirée Tempo Bleu HP" |
|
unit_of_measurement: kWh |
|
device_class: energy |
|
state_class: total_increasing |
|
accuracy_decimals: 3 |
|
filters: |
|
- multiply: 0.001 |
|
# Energie active soutirée Fournisseur, index 03 |
|
- platform: teleinfo |
|
tag_name: "EASF03" |
|
name: "Linky Energie Soutirée Tempo Blanc HC" |
|
unit_of_measurement: kWh |
|
device_class: energy |
|
state_class: total_increasing |
|
accuracy_decimals: 3 |
|
filters: |
|
- multiply: 0.001 |
|
# Energie active soutirée Fournisseur, index 04 |
|
- platform: teleinfo |
|
tag_name: "EASF04" |
|
name: "Linky Energie Soutirée Tempo Blanc HP" |
|
unit_of_measurement: kWh |
|
device_class: energy |
|
state_class: total_increasing |
|
accuracy_decimals: 3 |
|
filters: |
|
- multiply: 0.001 |
|
# Energie active soutirée Fournisseur, index 05 |
|
- platform: teleinfo |
|
tag_name: "EASF05" |
|
name: "Linky Energie Soutirée Tempo Rouge HC" |
|
unit_of_measurement: kWh |
|
device_class: energy |
|
state_class: total_increasing |
|
accuracy_decimals: 3 |
|
filters: |
|
- multiply: 0.001 |
|
# Energie active soutirée Fournisseur, index 06 |
|
- platform: teleinfo |
|
tag_name: "EASF06" |
|
name: "Linky Energie Soutirée Tempo Rouge HP" |
|
unit_of_measurement: kWh |
|
device_class: energy |
|
state_class: total_increasing |
|
accuracy_decimals: 3 |
|
filters: |
|
- multiply: 0.001 |
|
# # Energie active soutirée Fournisseur, index 07 |
|
# - platform: teleinfo |
|
# tag_name: "EASF07" |
|
# name: "Linky Energie Soutirée F07" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Energie active soutirée Fournisseur, index 08 |
|
# - platform: teleinfo |
|
# tag_name: "EASF08" |
|
# name: "Linky Energie Soutirée F08" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Energie active soutirée Fournisseur, index 09 |
|
# - platform: teleinfo |
|
# tag_name: "EASF09" |
|
# name: "Linky Energie Soutirée F09" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Energie active soutirée Fournisseur, index 10 |
|
# - platform: teleinfo |
|
# tag_name: "EASF10" |
|
# name: "Linky Energie Soutirée F10" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Energie active soutirée Distributeur, index 01 |
|
# - platform: teleinfo |
|
# tag_name: "EASD01" |
|
# name: "Linky Energie Soutirée D01" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Energie active soutirée Distributeur, index 02 |
|
# - platform: teleinfo |
|
# tag_name: "EASD02" |
|
# name: "Linky Energie Soutirée D02" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Energie active soutirée Distributeur, index 03 |
|
# - platform: teleinfo |
|
# tag_name: "EASD03" |
|
# name: "Linky Energie Soutirée D03" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Energie active soutirée Distributeur, index 04 |
|
# - platform: teleinfo |
|
# tag_name: "EASD04" |
|
# name: "Linky Energie Soutirée D04" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# Courant Efficace, phase 1 |
|
- platform: teleinfo |
|
tag_name: "IRMS1" |
|
name: "Linky Courant Efficace" |
|
unit_of_measurement: A |
|
device_class: current |
|
state_class: measurement |
|
# Tension Efficace, phase 1 |
|
- platform: teleinfo |
|
tag_name: "URMS1" |
|
name: "Linky Tension Efficace" |
|
unit_of_measurement: V |
|
device_class: voltage |
|
state_class: measurement |
|
# Puissance app. de référence |
|
# - platform: teleinfo |
|
# tag_name: "PREF" |
|
# name: "Linky Puissance Apparente Référence" |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# unit_of_measurement: VA |
|
# filters: |
|
# - multiply: 1000 |
|
# Puissance app. de coupure |
|
- platform: teleinfo |
|
tag_name: "PCOUP" |
|
name: "Linky Puissance Apparente Coupure" |
|
state_class: measurement |
|
device_class: apparent_power |
|
unit_of_measurement: VA |
|
filters: |
|
- multiply: 1000 |
|
# Puissance app. Instantanée Soutirée |
|
- platform: teleinfo |
|
tag_name: "SINSTS" |
|
name: "Linky Puissance Apparente Instantanée Soutirée" |
|
unit_of_measurement: VA |
|
state_class: measurement |
|
device_class: apparent_power |
|
# Puissance app. max. soutirée |
|
# - platform: teleinfo |
|
# tag_name: "SMAXSN" |
|
# name: "Linky Puissance Apparente Maximale Soutirée" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# Point n de la courbe de charge active soutirée |
|
- platform: teleinfo |
|
tag_name: "CCASN" |
|
name: "Linky Puissance Active Soutirée" |
|
unit_of_measurement: W |
|
state_class: measurement |
|
device_class: power |
|
# Point n-1 de la courbe de charge active soutirée |
|
- platform: teleinfo |
|
tag_name: "CCASN-1" |
|
name: "Linky Puissance Active Soutirée N-1" |
|
unit_of_measurement: W |
|
state_class: measurement |
|
device_class: power |
|
# Tension Moyenne, phase 1 |
|
# - platform: teleinfo |
|
# tag_name: "UMOY1" |
|
# name: "Linky Tension Moyenne" |
|
# unit_of_measurement: V |
|
# device_class: voltage |
|
# state_class: measurement |
|
#------------------------- |
|
# MODE STANDARD - TRIPHASÉ |
|
#------------------------- |
|
# # Courant Efficace, phase 2 |
|
# - platform: teleinfo |
|
# tag_name: "IRMS2" |
|
# name: "Linky Courant Efficace Phase 2" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Courant Efficace, phase 3 |
|
# - platform: teleinfo |
|
# tag_name: "IRMS3" |
|
# name: "Linky Courant Efficace Phase 3" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Tension Efficace, phase 2 |
|
# - platform: teleinfo |
|
# tag_name: "URMS2" |
|
# name: "Linky Tension Efficace Phase 2" |
|
# unit_of_measurement: V |
|
# device_class: voltage |
|
# state_class: measurement |
|
# # Tension Efficace, phase 3 |
|
# - platform: teleinfo |
|
# tag_name: "URMS3" |
|
# name: "Linky Tension Efficace Phase 3" |
|
# unit_of_measurement: V |
|
# device_class: voltage |
|
# state_class: measurement |
|
# # Puissance app. Instantanée Soutirée, phase 1 |
|
# - platform: teleinfo |
|
# tag_name: "SINSTS1" |
|
# name: "Linky Puissance Apparente Instantanée Soutirée Phase 1" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Puissance app. Instantanée Soutirée, phase 2 |
|
# - platform: teleinfo |
|
# tag_name: "SINSTS2" |
|
# name: "Linky Puissance Apparente Instantanée Soutirée Phase 2" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Puissance app. Instantanée Soutirée, phase 3 |
|
# - platform: teleinfo |
|
# tag_name: "SINSTS3" |
|
# name: "Linky Puissance Apparente Instantanée Soutirée Phase 3" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Puissance app. max. Soutirée, phase 1 |
|
# - platform: teleinfo |
|
# tag_name: "SMAXSN1" |
|
# name: "Linky Puissance Apparente Maximale Soutirée Phase 1" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Puissance app. max. Soutirée, phase 2 |
|
# - platform: teleinfo |
|
# tag_name: "SMAXSN2" |
|
# name: "Linky Puissance Apparente Maximale Soutirée Phase 2" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Puissance app. max. Soutirée, phase 3 |
|
# - platform: teleinfo |
|
# tag_name: "SMAXSN3" |
|
# name: "Linky Puissance Apparente Maximale Soutirée Phase 3" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Tension Moyenne, phase 2 |
|
# - platform: teleinfo |
|
# tag_name: "UMOY2" |
|
# name: "Linky Tension Moyenne Phase 2" |
|
# unit_of_measurement: V |
|
# device_class: voltage |
|
# state_class: measurement |
|
# # Tension Moyenne, phase 3 |
|
# - platform: teleinfo |
|
# tag_name: "UMOY3" |
|
# name: "Linky Tension Moyenne Phase 3" |
|
# unit_of_measurement: V |
|
# device_class: voltage |
|
# state_class: measurement |
|
#---------------------------- |
|
# MODE STANDARD - PRODUCTEURS |
|
#---------------------------- |
|
# # Energie active injectée totale |
|
# - platform: teleinfo |
|
# tag_name: "EAIT" |
|
# name: "Linky Energie Injectée" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Puissance app. Instantanée Injectée |
|
# - platform: teleinfo |
|
# tag_name: "SINSTI" |
|
# name: "Linky Puissance Apparente Instantanée Injectée" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Puissance app. Maximale Injectée |
|
# - platform: teleinfo |
|
# tag_name: "SMAXIN" |
|
# name: "Linky Puissance Apparente Maximale Injectée" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
# # Point n de la courbe de charge active injectée |
|
# - platform: teleinfo |
|
# tag_name: "CCAIN" |
|
# name: "Linky Puissance Active Injectée" |
|
# unit_of_measurement: W |
|
# state_class: measurement |
|
# device_class: power |
|
# # Point n-1 de la courbe de charge active injectée |
|
# - platform: teleinfo |
|
# tag_name: "CCAIN-1" |
|
# name: "Linky Puissance Active Injectée N-1" |
|
# unit_of_measurement: W |
|
# state_class: measurement |
|
# device_class: power |
|
#---------------- |
|
# MODE HISTORIQUE |
|
#---------------- |
|
# # Intensité souscrite |
|
# - platform: teleinfo |
|
# tag_name: "ISOUSC" |
|
# name: "Linky Intensité souscrite" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Index option Base |
|
# - platform: teleinfo |
|
# tag_name: "BASE" |
|
# name: "Linky Index Base" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Index option HP/HC |
|
# - platform: teleinfo |
|
# tag_name: "HCHC" |
|
# name: "Linky Index HC" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# - platform: teleinfo |
|
# tag_name: "HCHP" |
|
# name: "Linky Index HP" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Index option EJP |
|
# - platform: teleinfo |
|
# tag_name: "EJPHN" |
|
# name: "Linky Index EJP Normal" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# - platform: teleinfo |
|
# tag_name: "EJPHPM" |
|
# name: "Linky Index EJP Pointe" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Index option Tempo |
|
# - platform: teleinfo |
|
# tag_name: "BBRHCJB" |
|
# name: "Linky Index Tempo Bleu HC" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# - platform: teleinfo |
|
# tag_name: "BBRHPJB" |
|
# name: "Linky Index Tempo Bleu HP" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# - platform: teleinfo |
|
# tag_name: "BBRHCJW" |
|
# name: "Linky Index Tempo Blanc HC" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# - platform: teleinfo |
|
# tag_name: "BBRHPJW" |
|
# name: "Linky Index Tempo Blanc HP" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# - platform: teleinfo |
|
# tag_name: "BBRHCJR" |
|
# name: "Linky Index Tempo Rouge HC" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# - platform: teleinfo |
|
# tag_name: "BBRHPJR" |
|
# name: "Linky Index Tempo Rouge HP" |
|
# unit_of_measurement: kWh |
|
# device_class: energy |
|
# state_class: total_increasing |
|
# accuracy_decimals: 3 |
|
# filters: |
|
# - multiply: 0.001 |
|
# # Intensité Instantanée (monophasé) |
|
# - platform: teleinfo |
|
# tag_name: "IINST" |
|
# name: "Linky Intensité Instantanée" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Avertissement de Dépassement De Puissance Souscrite |
|
# - platform: teleinfo |
|
# tag_name: "ADPS" |
|
# name: "Linky Intensité Instantanée Dépassement" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Intensité maximale appelée (monophasé) |
|
# - platform: teleinfo |
|
# tag_name: "IMAX" |
|
# name: "Linky Intensité Maximale" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Puissance apparente |
|
# - platform: teleinfo |
|
# tag_name: "PAPP" |
|
# name: "Linky Puissance Apparente" |
|
# unit_of_measurement: VA |
|
# state_class: measurement |
|
# device_class: apparent_power |
|
#--------------------------- |
|
# MODE HISTORIQUE - TRIPHASÉ |
|
#--------------------------- |
|
# # Intensité Instantanée, phase 1 |
|
# - platform: teleinfo |
|
# tag_name: "IINST1" |
|
# name: "Linky Intensité Instantanée Phase 1" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Intensité Instantanée, phase 2 |
|
# - platform: teleinfo |
|
# tag_name: "IINST2" |
|
# name: "Linky Intensité Instantanée Phase 2" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Intensité Instantanée, phase 3 |
|
# - platform: teleinfo |
|
# tag_name: "IINST3" |
|
# name: "Linky Intensité Instantanée Phase 3" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Intensité maximale appelée, phase 1 |
|
# - platform: teleinfo |
|
# tag_name: "IMAX1" |
|
# name: "Linky Intensité Maximale Phase 1" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Intensité maximale appelée, phase 2 |
|
# - platform: teleinfo |
|
# tag_name: "IMAX2" |
|
# name: "Linky Intensité Maximale Phase 2" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Intensité maximale appelée, phase 3 |
|
# - platform: teleinfo |
|
# tag_name: "IMAX3" |
|
# name: "Linky Intensité Maximale Phase 3" |
|
# unit_of_measurement: A |
|
# device_class: current |
|
# state_class: measurement |
|
# # Puissance maximale atteinte |
|
# - platform: teleinfo |
|
# tag_name: "PMAX" |
|
# name: "Linky Puissance Maximale" |
|
# unit_of_measurement: W |
|
# state_class: measurement |
|
# device_class: power |
|
|
|
# https://esphome.io/components/text_sensor/index.html |
|
text_sensor: |
|
- platform: wifi_info |
|
ip_address: |
|
name: Linky IP Address |
|
mac_address: |
|
name: Linky Wifi Mac Address |
|
ssid: |
|
name: Linky Wifi SSID |
|
bssid: |
|
name: Linky Wifi BSSID |
|
#-------------- |
|
# MODE STANDARD |
|
#-------------- |
|
# # Adresse Secondaire du Compteur |
|
# - platform: teleinfo |
|
# tag_name: "ADSC" |
|
# name: "Linky Adresse Secondaire" |
|
# Nom du calendrier tarifaire fournisseur |
|
- platform: teleinfo |
|
tag_name: "NGTF" |
|
name: "Linky Calendrier Tarifaire" |
|
icon: mdi:information |
|
# Libellé tarif fournisseur en cours |
|
- platform: teleinfo |
|
tag_name: "LTARF" |
|
name: "Linky Tarif Actuel" |
|
icon: mdi:information |
|
# Registre de Statuts |
|
# - platform: teleinfo |
|
# tag_name: "STGE" |
|
# name: "Linky Registre de Statuts" |
|
# icon: mdi:information |
|
# # Message court |
|
# - platform: teleinfo |
|
# tag_name: "MSG1" |
|
# name: "Linky Message court" |
|
# # Message Ultra court |
|
# - platform: teleinfo |
|
# tag_name: "MSG2" |
|
# name: "Linky Message Ultra court" |
|
# # PRM |
|
# - platform: teleinfo |
|
# tag_name: "PRM" |
|
# name: "Linky PRM" |
|
# # Relais |
|
# - platform: teleinfo |
|
# tag_name: "RELAIS" |
|
# name: "Linky Relais" |
|
#---------------- |
|
# MODE HISTORIQUE |
|
#---------------- |
|
# # Adresse du compteur |
|
# - platform: teleinfo |
|
# tag_name: "ADCO" |
|
# name: "Linky Adresse" |
|
# # Option tarifaire choisie |
|
# - platform: teleinfo |
|
# tag_name: "OPTARIF" |
|
# name: "Linky Option Tarifaire" |
|
# # Préavis Début EJP (30 min) |
|
# - platform: teleinfo |
|
# tag_name: "PEJP" |
|
# name: "Linky Préavis EJP" |
|
# # Période Tarifaire en cours |
|
# - platform: teleinfo |
|
# tag_name: "PTEC" |
|
# name: "Linky Période Tarifaire" |
|
# # Couleur du lendemain |
|
# - platform: teleinfo |
|
# tag_name: "DEMAIN" |
|
# name: "Linky Couleur Demain" |
|
# # Horaire Heures Pleines Heures Creuses |
|
# - platform: teleinfo |
|
# tag_name: "HHPHC" |
|
# name: "Linky Horaire HP/HC" |
|
# # Mot d'état du compteur |
|
# - platform: teleinfo |
|
# tag_name: "MOTDETAT" |
|
# name: "Linky Mot d'état" |
|
# # Présence des potentiels |
|
# - platform: teleinfo |
|
# tag_name: "PPOT" |
|
# name: "Linky Présence Potentiels" |
Merci pour votre réponse claire et complète!
On est bien d'accord que la puissance apparente est ce qui circule, et est nécessaire pour dimensionner les circuits. Mais un consommateur (privé) ne paie que l’énergie active, pas la partie réactive.
Notre société a développe et mis en vente (voir https://amsleser.no) un solution pour lire les données de plusieurs interfaces "standard" utilisées sur compteurs dans un nombre de pays Européens, vendu aux consommateurs privées. L'appareil génère un tableau de bord sur une page web sur une adresse IP interne, et transmettra éventuellement aussi les données via MQTT. Pas d'abonnement, tous données gérés en interne par l'utilisateur.
Notre firmware: https://github.com/UtilitechAS/amsreader-firmware
Guide d'exploitation du firmware: https://wiki.amsleser.no/en/firmware
Distribution géographique de nos clients: https://www.amsleser.no/module/ets_blog/blog?id_post=11
On est en train de considérer si on devrait développer un produit pour lire les Linky. Pour nos clients c'est typiquement l'énergie active qui est le plus intéressant - car c'est ce qu'on trouve sur la facture.
Je ne trouve pas dans la liste de paramètres dans le document Enedis le Facteur de puissance, cos(phi) non plus.
Votre logiciel montre la puissance active, c'est donc à partir d'un Shelly EM? Ou peut-on le calculer à partir des données sortant du Linky?
Je vois bien que Linky donne tension et courant RMS, mais dans un système triphasé la somme des (I * U) ne donne pas la bonne réponse que si les charges sont égaux sur les trois phases - ce qui n'est "jamais" le cas.