JSONified FileMaker error codes and corresponding messages.
{
"-1": "Unknown error",
"0": "No error",
"1": "User canceled action",
"2": "Memory error",
"3": "Command is unavailable (for example, wrong operating system, wrong mode, etc.)",
"4": "Command is unknown",
"5": "Command is invalid (for example, a Set Field script step does not have a calculation specified)",
"6": "File is read-only",
"7": "Running out of memory",
"8": "Empty result",
"9": "Insufficient privileges to modify/access data",
"10": "Requested data is missing",
"11": "Name is not valid",
"12": "Name already exists",
"13": "File or object is in use",
"14": "Out of range",
"15": "Can't divide by zero",
"16": "Operation failed, request retry (for example, a user query)",
"17": "Attempt to convert foreign character set to UTF-16 failed",
"18": "Client must provide account information to proceed",
"19": "String contains characters other than A-Z, a-z, 0-9 (ASCII)",
"20": "Command/operation cancelled by triggered script",
"21": "Map Win 32 error of 'ERROR_NOT_SUPPORTED'. Microsoft documentation is 'the request is not supported'.",
"26": "The file path specified is not a valid file path",
"100": "File is missing",
"101": "Record is missing",
"102": "Field is missing",
"103": "Relationship is missing",
"104": "Script is missing",
"105": "Layout is missing",
"106": "Table is missing",
"107": "Index is missing",
"108": "Value list is missing",
"109": "Privilege set is missing",
"110": "Related tables are missing",
"111": "Field repetition is invalid",
"112": "Window is missing",
"113": "Function is missing",
"114": "File reference is missing",
"115": "Specified menu set is not present",
"116": "Specified layout object is not present",
"117": "Specified data source is not present",
"130": "Files are damaged or missing and must be reinstalled",
"131": "Language pack files are missing (such as template files)",
"200": "Record access is denied",
"201": "Field cannot be modified",
"202": "Field access is denied",
"203": "No records in file to print, or password doesn't allow print access",
"204": "No access to field(s) in sort order",
"205": "User does not have access privileges to create new records; import will overwrite existing data",
"206": "User does not have password change privileges, or file is not modifiable",
"207": "User does not have sufficient privileges to change database schema, or file is not modifiable",
"208": "Password does not contain enough characters",
"209": "New password must be different from existing one",
"210": "User account is inactiveUser account is inactive",
"211": "Password has expired",
"212": "Invalid user account and/or password. Please try again",
"213": "User account and/or password does not exist",
"214": "Too many login attempts",
"215": "Administrator privileges cannot be duplicated",
"216": "Guest account cannot be duplicated",
"217": "User does not have sufficient privileges to modify administrator accountUser does not have sufficient privileges to modify administrator account",
"218": "Password and verify password do not match (iPhone)",
"300": "File is locked or in use",
"301": "Record is in use by another user",
"302": "Table is in use by another user",
"303": "Database schema is in use by another user",
"304": "Layout is in use by another user",
"306": "Record modification ID does not match",
"307": "Lost connection to the host and the transaction could not relock",
"400": "Find criteria are empty",
"401": "No records match the request",
"402": "Selected field is not a match field for a lookup",
"403": "Exceeding maximum record limit for trial version of FileMaker Pro",
"404": "Sort order is invalid",
"405": "Number of records specified exceeds number of records that can be omitted",
"406": "Replace/Reserialize criteria are invalid",
"407": "One or both match fields are missing (invalid relationship)",
"408": "Specified field has inappropriate data type for this operation",
"409": "Import order is invalid",
"410": "Export order is invalid",
"412": "Wrong version of FileMaker Pro used to recover file",
"413": "Specified field has inappropriate field type",
"414": "Layout cannot display the result",
"415": "One or more required related records are not available",
"416": "Primary key required from data source table",
"417": "Database is not supported for ODBC operations",
"418": "The base directory specified in the CREATE TABLE ... field blob EXTERNAL 'path' not found",
"500": "Date value does not meet validation entry options",
"501": "Time value does not meet validation entry options",
"502": "Number value does not meet validation entry options",
"503": "Value in field is not within the range specified in validation entry options",
"504": "Value in field is not unique as required in validation entry options",
"505": "Value in field is not an existing value in the database file as required in validation entry options",
"506": "Value in field is not listed on the value list specified in validation entry option",
"507": "Value in field failed calculation test of validation entry option",
"508": "Invalid value entered in Find mode",
"509": "Field requires a valid value",
"510": "Related value is empty or unavailable",
"511": "Value in field exceeds maximum field size",
"512": "Record was already modified by another user",
"513": "Record must have a value in some field to be created",
"600": "Print error has occurred",
"601": "Combined header and footer exceed one page",
"602": "Body doesn't fit on a page for current column setup",
"603": "Print connection lost",
"700": "File is of the wrong file type for import",
"706": "EPSF file has no preview image",
"707": "Graphic translator cannot be found",
"708": "Can't import the file or need color monitor support to import file",
"709": "QuickTime movie import failed",
"710": "Unable to update QuickTime reference because the database file is read-only",
"711": "Import translator cannot be found",
"714": "Password privileges do not allow the operation",
"715": "Specified Excel worksheet or named range is missing",
"716": "A SQL query using DELETE, INSERT, or UPDATE is not allowed for ODBC import",
"717": "There is not enough XML/XSL information to proceed with the import or export",
"718": "Error in parsing XML file (from Xerces)",
"719": "Error in transforming XML using XSL (from Xalan)",
"720": "Error when exporting; intended format does not support repeating fields",
"721": "Unknown error occurred in the parser or the transformer",
"722": "Cannot import data into a file that has no fields",
"723": "You do not have permission to add records to or modify records in the target table",
"724": "You do not have permission to add records to the target table",
"725": "You do not have permission to modify records in the target table",
"726": "There are more records in the import file than in the target table. Not all records were imported",
"727": "There are more records in the target table than in the import file. Not all records were updated",
"729": "Errors occurred during import. Records could not be imported",
"730": "Unsupported Excel version. (Convert file to Excel 7.0 (Excel 95), Excel 97, 2000, or XP format and try again)",
"731": "The file you are importing from contains no data",
"732": "This file cannot be inserted because it contains other files",
"733": "A table cannot be imported into itself",
"734": "This file type cannot be displayed as a picture",
"735": "This file type cannot be displayed as a picture. It will be inserted and displayed as a file",
"736": "Too much data to export to this format. It will be truncated",
"737": "Bento table is reported as missed when trying to import it",
"738" : "A theme with that name already exists in. Do you want to replace it with the theme that you are importing?",
"800": "Unable to create file on disk",
"801": "Unable to create temporary file on System disk",
"802": "Unable to open file",
"803": "File is single user or host cannot be found",
"804": "File cannot be opened as read-only in its current state",
"805": "File is damaged; use Recover command",
"806": "File cannot be opened with this version of FileMaker Pro",
"807": "File is not a FileMaker Pro file or is severely damaged",
"808": "Cannot open file because access privileges are damaged",
"809": "Disk/volume is full",
"810": "Disk/volume is locked",
"811": "Temporary file cannot be opened as FileMaker Pro file",
"813": "Record Synchronization error on network",
"814": "File(s) cannot be opened because maximum number is open",
"815": "Couldn't open lookup file",
"816": "Unable to convert file",
"817": "Unable to open file because it does not belong to this solution",
"819": "Cannot save a local copy of a remote file",
"820": "File is in the process of being closed",
"821": "Host forced a disconnect",
"822": "FMI files not found; reinstall missing files",
"823": "Cannot set file to single-user, guests are connected",
"824": "File is damaged or not a FileMaker file",
"825": "File is not authorized to reference the protected file",
"827": "File was not created because the source contained no data or is a reference. (new to FileMaker Pro 14)",
"850": "This path is not valid (for the platform it represents)",
"851": "The external file can not be deleted from disk. Do you want to delete the reference to the file anyway?",
"852": "Can not write file to the external storage.",
"853": "One or more containers failed to transfer",
"900": "General spelling engine error",
"901": "Main spelling dictionary not installed",
"902": "Could not launch the Help system",
"903": "Command cannot be used in a shared file",
"905": "No active field selected; command can only be used if there is an active field",
"906": "Current file must be shared in order to use this command",
"920": "Can't initialize the spelling engine",
"921": "User dictionary cannot be loaded for editing",
"922": "User dictionary cannot be found",
"923": "User dictionary is read-only",
"951": "An unexpected error occurred (*)",
"954": "Unsupported XML grammar (*)",
"955": "No database name (*)",
"956": "Maximum number of database sessions exceeded (*)",
"957": "Conflicting commands (*)",
"958": "Parameter missing (*)",
"1200": "Generic calculation error",
"1201": "Too few parameters in the function",
"1202": "Too many parameters in the function",
"1203": "Unexpected end of calculation",
"1204": "Number, text constant, field name or '(' expected",
"1205": "Comment is not terminated with '*/'",
"1206": "Text constant must end with a quotation mark",
"1207": "Unbalanced parenthesis",
"1208": "Operator missing, function not found or '(' not expected",
"1209": "Name (such as field name or layout name) is missing",
"1210": "Plug-in function has already been registered",
"1211": "List usage is not allowed in this function",
"1212": "An operator (for example, +, -, *) is expected here",
"1213": "This variable has already been defined in the Let function",
"1214": "AVERAGE, COUNT, EXTEND, GETREPETITION, MAX, MIN, NPV, STDEV, SUM and GETSUMMARY: expression found where a field alone is needed",
"1215": "This parameter is an invalid Get function parameter",
"1216": "Only Summary fields allowed as first argument in GETSUMMARY",
"1217": "Break field is invalid",
"1218": "Cannot evaluate the number",
"1219": "A field cannot be used in its own formula",
"1220": "Field type must be normal or calculated",
"1221": "Data type must be number, date, time, or timestamp",
"1222": "Calculation cannot be stored",
"1223": "The function is not implemented",
"1224": "The function is not defined",
"1225": "The function is not supported in this context",
"1300": "The specified name can't be used",
"1400": "ODBC driver initialization failed; make sure the ODBC drivers are properly installed",
"1401": "Failed to allocate environment (ODBC)",
"1402": "Failed to free environment (ODBC)",
"1403": "Failed to disconnect (ODBC)",
"1404": "Failed to allocate connection (ODBC)",
"1405": "Failed to free connection (ODBC)",
"1406": "Failed check for SQL API (ODBC)",
"1407": "Failed to allocate statement (ODBC)",
"1408": "Extended error (ODBC)",
"1409": "Error (ODBC)",
"1413": "Failed communication link (ODBC)",
"1414": "ODBC/SQL Statement Too Long",
"1450": "Action requires PHP privilege extension (*)",
"1451": "Action requires that current file be remote",
"1501": "The authentication Failed.",
"1502": "The connection was refused by the SMTP server.",
"1503": "There was an error with SSL.",
"1504": "The server required the connection to be encrypted.",
"1505": "The specified authentication is not supported by the SMTP server.",
"1506": "Email(s) could not be sent successfully.",
"1507": "Unable to login into the SMTP Server.",
"1550": "The file isn't a plugin, or can't load for some reason",
"1551": "Can't delete existing plugin, can't write to the folder, can't put on disk for some reason",
"1626": "The protocol is not supported",
"1627": "The authentication Failed.",
"1628": "There was an error with SSL.",
"1629": "The connection timed out",
"1630": "The url format is incorrect",
"1631": "The connection failed",
"1632": "The certificate has expired. (previously, The Certificate cannot be authenticated by a supported CA)",
"1633": "The certificate is self-signed. (previously, The Certificate is valid, but still wrong. e.g. hostname doesn't match, or expired)",
"1634": "A certificate verification error occurred. (new to FileMaker Pro 15)",
"2021": "plug-ins configuration disallowed",
"2046": "This command or action cannot be performed because that functionality is no longer supported",
"2047": "Bento 2 (or later) is not presented on the system",
"2048": "The selected work book is not excel 2007/2008 format",
"2056": "This script step cannot be performed because this window is in a modal state.",
"3000": "Action never occurred because script was triggered",
"3001": "Set when a step returns but is not really finished (probably due to having to switch threads and keep engine thread running)",
"3002": "The external file can not be deleted from disk. Do you want to delete the reference to the file anyway?",
"3003": "Can not write file to the external storage.",
"3004": "Directory Cant Edit",
"3005": "Directory Cant Delete",
"3100": "Theme is in use",
"3219": "Convert Global To Remote Warning",
"3220": "Directory Not Accessible Warning",
"3316": "Wrning before clearing out existing find requests",
"3317": "Wrning before attempting to restore files from hibernation",
"3319": "Warning: SSL certificate is invalid. Do you want to continue? (new to FileMaker Pro 14, removed in FileMaker Pro 15)",
"3320": "Warning: SSL certificate could not be verified. Do you want to continue? (new to FileMaker Pro 14, removed in FileMaker Pro 15)",
"3427": "Button cannot contain a tab control [NEW in FMP 8.0, modified in FMP 13.0",
"3428": "When a panel is deleted, all the objects on that panel will be deleted [NEW in FMP 8.0, modified in FMP 13.0",
"3429": "One or more of the panels you've selected contain locked objects. Do you you want to delete those panel(s) even though they contain locked object(s)? [NEW in FMP 8.0, modified in FMP 13.0",
"3956": "The total size of all base directory paths cannot exceed ^1 bytes.",
"3958": "Please select at least one bar code type",
"3957": "At least one filter must remain.",
"3959": "'At least one window orientation must be enabled.' (new to FileMaker Pro 14)",
"4049": "'To view FileMaker Pro Help, you must be connected to the Internet.' (new to FileMaker Pro 15)",
"4103": "File path is invalid or cannot be resolved during file transfer",
"4104": "File i/o issue during file transfer",
"4106": "The target base directory is not valid.",
"4107": "The target base directory could not be created.",
"4603": "Spell Export Complete",
"4687": "'To view FileMaker Pro update information, you must be connected to the Internet.' (new to FileMaker Pro 15)",
"4688": "'Internet connection failed. Cannot check for update information.' (new to FileMaker Pro 15)",
"4689": "'No update available right now.' (new to FileMaker Pro 15)",
"4709": "Unsupported svg, can not be imported. (new to FileMaker Pro 14)",
"7100": "Data Deferred",
"8404": "An installed OnTimer script could not be found or could not be run with current access privileges",
"8213": "Too many temporary objects created, can't create any more.",
"8310": "There is an error in the syntax of the query.",
"8498": "Stale Import Order To Be Updated",
"8499": "Import Match May Be Invalid",
"20413": "Too Many Files",
"20605": "No network connection is available",
"20606": "Fail to resolve network address",
"20650": "Page doesn't have enough footer size for encryption (new to FileMaker Pro 14)"
}