blueprint: | |
name: Target temperature adjustment depending on second temperature sensor | |
description: > | |
Sets target temperature depending on second temperature sensor. | |
This blueprint is inspired by this blueprint https://community.home-assistant.io/t/tado-set-offset-using-separate-temperature-sensor/288515 | |
created by Sanderma. Since not all thermostat devices have an configurable | |
offset, this blueprint sets the target temperature of the thermostat device | |
depending on a given target temperature and a second temperature sensor. | |
domain: automation | |
input: | |
temperature_sensor: | |
name: Temperature sensor | |
description: This sensor will be used as the source. | |
selector: | |
entity: | |
domain: sensor | |
device_class: temperature | |
thermostat: | |
name: Thermostat | |
description: The thermostat to set target temperature | |
selector: | |
entity: | |
domain: climate | |
target_temperature: | |
name: Target temperature | |
description: Target temperature of the thermostat | |
selector: | |
number: | |
min: 5 | |
max: 30 | |
step: 0.5 | |
unit_of_measurement: "°C" | |
default: 21 | |
variables: | |
thermostat: !input thermostat | |
temperature_sensor: !input temperature_sensor | |
target_temperature: !input target_temperature | |
actual_temperature: "{{ states(temperature_sensor) | float }}" | |
calculated_adjustment: "{{ target_temperature - actual_temperature }}" | |
calculated_target_temperature: "{{ ( ( ( target_temperature + calculated_adjustment ) * 2 ) | round ) / 2 }}" | |
trigger: | |
- platform: state | |
entity_id: !input thermostat | |
attribute: "{{ current_temperature_attribute }}" | |
- platform: state | |
entity_id: !input temperature_sensor | |
condition: "{{ calculated_adjustment != 0 }}" | |
action: | |
- service: system_log.write | |
data: | |
message: > | |
{{ thermostat }} has temp difference of {{ calculated_adjustment }}. Setting target temperature to {{ calculated_target_temperature }} | |
level: info | |
logger: blueprints.nevesenin.target_temperature_adjustment | |
- service: system_log.write | |
data: | |
message: > | |
thermostat: {{ thermostat }}, | |
temperature_sensor: {{ temperature_sensor }}, | |
target_temperature: {{ target_temperature }}, | |
actual_temperature: {{ actual_temperature }}, | |
calculated_adjustment: {{ calculated_adjustment }}, | |
calculated_target_temperature: {{ calculated_target_temperature }} | |
level: debug | |
logger: blueprints.nevesenin.target_temperature_adjustment | |
- service: climate.set_temperature | |
data: | |
temperature: "{{ calculated_target_temperature }}" | |
entity_id: "{{ thermostat }}" | |
mode: single |