Created
April 22, 2023 06:32
-
-
Save nickknissen/70f0eeeb527b634f234c53b7f733301a to your computer and use it in GitHub Desktop.
Carlo Gavazzi EM340 pulse out monitor
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
substitutions: | |
energy_name: Heatpump | |
esphome: | |
name: heatpump-energy | |
esp32: | |
board: esp32dev | |
framework: | |
type: esp-idf | |
logger: | |
#captive_portal: | |
improv_serial: | |
api: | |
services: | |
- service: meter_reading_kwh | |
variables: | |
meter_value: float | |
then: | |
- globals.set: | |
id: ${energy_name}_initial_kwh_usage | |
value: !lambda "return ( meter_value ) ;" | |
ota: | |
password: "f9a8fc5386d47d53b7993eab4fbff620" | |
wifi: | |
ssid: !secret wifi_ssid | |
password: !secret wifi_password | |
button: | |
- platform: restart | |
name: " heatpump energy Restart device" | |
### NEW | |
globals: | |
- id: ${energy_name}_initial_kwh_usage | |
type: float | |
restore_value: yes | |
initial_value: '698.24' | |
- id: ${energy_name}_total_kwh_pulses | |
type: int | |
restore_value: yes | |
number: | |
- platform: template | |
id: ${energy_name}_select_pulse_rate | |
name: '${energy_name} Pulsrate kWh' | |
optimistic: true | |
mode: box | |
min_value: '10' | |
max_value: '4000' | |
step: '10' | |
restore_value: yes | |
initial_value: '1000' | |
binary_sensor: | |
- platform: gpio | |
id: ${energy_name}_internal_pulse_counter | |
name: ${energy_name} Pulse Sensor kwh | |
pin: | |
number: GPIO02 | |
mode: INPUT_PULLUP | |
on_press: | |
- then: | |
lambda: id(${energy_name}_total_kwh_pulses) += 1; | |
sensor: | |
- platform: pulse_meter | |
pin: | |
number: GPIO02 | |
mode: INPUT_PULLUP | |
name: "${energy_name} Current energy" | |
id: actual_power | |
icon: "mdi:flash" | |
# internal_filter: ${impulslengte} | |
accuracy_decimals: 3 | |
unit_of_measurement: 'kW' | |
state_class: measurement | |
device_class: power | |
filters: | |
lambda: return x * (60.0 / id(${energy_name}_select_pulse_rate).state); | |
total: | |
unit_of_measurement: 'kWh' | |
name: "${energy_name} Total consumed" | |
id: ${energy_name}_total_energy_consumed | |
state_class: total_increasing | |
device_class: energy | |
icon: "mdi:flash" | |
accuracy_decimals: 3 | |
filters: | |
- lambda: return x * (1.0 / id(${energy_name}_select_pulse_rate).state); | |
- platform: template | |
id: ${energy_name}_kwh_total | |
name: "${energy_name} Total consumption since start" | |
state_class: "total_increasing" | |
device_class: energy | |
icon: "mdi:flash" | |
update_interval: 1s | |
unit_of_measurement: 'kWh' | |
accuracy_decimals: 3 | |
lambda: return id(${energy_name}_initial_kwh_usage) + (id(${energy_name}_total_kwh_pulses) * 0.001); | |
- platform: template | |
id: ${energy_name}_kwh_pulses | |
name: "${energy_name} kwh pulses total" | |
state_class: "total_increasing" | |
lambda: return id(${energy_name}_total_kwh_pulses); |
Sign up for free