blueprint: | |
name: Appliance monitor | |
description: Do something when an appliance (like a washing machine or dishwasher) | |
has finished as detected by a power sensor. | |
domain: automation | |
input: | |
power_sensor: | |
name: Power Sensor | |
description: Power sensor entity (e.g. from a smart plug device). | |
selector: | |
entity: | |
domain: sensor | |
starting_threshold: | |
name: Starting power threshold | |
description: Power threshold above which we assume the appliance has started. | |
default: 5 | |
selector: | |
number: | |
min: 1.0 | |
max: 100.0 | |
unit_of_measurement: W | |
mode: slider | |
step: 1.0 | |
starting_hysteresis: | |
name: Starting hysteresis | |
description: Time duration the power measurement has to stay above the starting | |
power threshold. | |
default: 5 | |
selector: | |
number: | |
min: 0.25 | |
max: 60.0 | |
unit_of_measurement: min | |
mode: slider | |
step: 0.25 | |
finishing_threshold: | |
name: Finishing power threshold | |
description: Power threshold below which we assume the appliance has finished. | |
default: 5 | |
selector: | |
number: | |
min: 1.0 | |
max: 100.0 | |
unit_of_measurement: W | |
mode: slider | |
step: 1.0 | |
finishing_hysteresis: | |
name: Finishing hysteresis | |
description: Time duration the power measurement has to stay below the finishing | |
power threshold. | |
default: 5 | |
selector: | |
number: | |
min: 0.25 | |
max: 60.0 | |
unit_of_measurement: min | |
mode: slider | |
step: 0.25 | |
actions_on: | |
name: Action(s) when starting | |
default: [] | |
selector: | |
action: {} | |
actions_off: | |
name: Action(s) when finishing | |
default: [] | |
selector: | |
action: {} | |
trigger: | |
- platform: numeric_state | |
entity_id: !input 'power_sensor' | |
for: | |
minutes: !input 'starting_hysteresis' | |
above: !input 'starting_threshold' | |
condition: [] | |
action: | |
- choose: [] | |
default: !input 'actions_on' | |
- wait_for_trigger: | |
- platform: numeric_state | |
entity_id: !input 'power_sensor' | |
below: !input 'finishing_threshold' | |
for: | |
minutes: !input 'finishing_hysteresis' | |
- choose: [] | |
default: !input 'actions_off' | |
mode: single | |
max_exceeded: silent |