Last active
August 5, 2024 00:12
-
-
Save patrickdk77/b687448fecff68d8572ac79a27d07862 to your computer and use it in GitHub Desktop.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Template | |
{"NAME":"Tuya Siren","GPIO":[255,107,255,108,255,255,0,0,255,255,255,255,255],"FLAG":0,"BASE":54} | |
You must activate the template before using any of the tuya commands below. | |
Recommended rules for tasmota: | |
rule1 on system#boot backlog tuyasend4 102,0; tuyasend2 103,300; TuyaSend1 117,0 endon | |
rule1 1 | |
tuyamcu 11,104 | |
This will set the default alarm length (5min), music (0), volume (0 high), and assign relay1 (power1) to the alarm activation. | |
The alarm length and music doesn't appear to be retained during power cycles. | |
0x65 Power State 101 | |
55 aa 03 07 00 05 65 04 00 01 04 7c (on usb power) | |
55 aa 03 07 00 05 65 04 00 01 00 78 (on battery power, 0=full battery maybe (1/2/3 battery level?) | |
x66 Change Alarm sound | |
TuyaSend4 102,0 (0 to 11 on mine, other upto 17) | |
x67 Change Alarm seconds | |
TuyaSend2 103,10 (1 to 60 on mine, 1800 on another) | |
x68 Alarm sounding | |
TuyaSend4 104,0 (off) | |
TuyaSend4 104,1 (on) | |
55 aa 03 07 00 05 68 01 00 01 01 79 | |
55 aa 03 07 00 05 71 01 00 01 00 81 | |
x69 tempature reporting (105) | |
55 aa 03 07 00 08 69 02 00 04 00 00 00 c3 43 (tempature in C*10) | |
x6a humidity reporting (106) | |
55 aa 03 07 00 08 6a 02 00 04 00 00 00 3b bc (59%) | |
x6b temp alarm low in C | |
TuyaSend4 107,17 | |
55 aa 00 06 00 08 6b 02 00 04 00 00 00 11 8f | |
x6c temp alarm high in C | |
TuyaSend4 108,38 | |
55 aa 00 06 00 08 6c 02 00 04 00 00 00 26 a5 | |
x6d set humidity alarm low | |
TuyaSend4 109,40 | |
55 aa 00 06 00 08 6d 02 00 04 00 00 00 46 c6 low in percent | |
x6e set humidity alarm high | |
TuyaSend4 110,80 | |
55 aa 00 06 00 08 6e 02 00 04 00 00 00 50 d1 high in percent | |
x6f | |
x70 Change to C and F units | |
TuyaSend1 112,1 (on) | |
55 aa 00 06 00 05 70 01 00 01 01 7d (C) | |
55 aa 00 06 00 05 70 01 00 01 00 7c (F) | |
x71 alarm temp on and off | |
TuyaSend1 113,1 (on) | |
55 aa 00 06 00 05 71 01 00 01 01 7e (on) | |
55 aa 00 06 00 05 71 01 00 01 00 7d (off) | |
x72 humidity alarm on/off | |
TuyaSend1 114,1 (on) | |
55 aa 00 06 00 05 72 01 00 01 01 7f (on) | |
55 aa 00 06 00 05 72 01 00 01 00 7e (off) | |
x73 alarm temp/humidity triggered | |
0=high tempature | |
1=high humidity | |
2=low tempature | |
3=low humidity | |
4=? | |
5=all normal | |
55 aa 03 07 00 05 73 04 00 01 02 88 (2 tempature alarm) | |
55 aa 03 07 00 05 73 04 00 01 03 89 (3 humidity alarm) | |
55 aa 03 07 00 05 73 04 00 01 05 8b (5 all clear) | |
x74 Alarm db setting (loudness) | |
TuyaSend1 117,0 (high) | |
55 aa 00 06 00 05 74 04 00 01 02 85 Low | |
55 aa 00 06 00 05 74 04 00 01 01 84 secondary | |
55 aa 00 06 00 05 74 04 00 01 00 83 High | |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Hey @patrickdk77
Tell me about it, burning items because you want to tinker :-D
When you write eg. "55 aa 03 07 00 05 68 01 00 01 01 79" is that the codes sent via the UART?