# Feel free to use if it helps. | |
# Forked from all over the place. | |
### | |
############################################################################### | |
# INPUT PLUGINS # | |
############################################################################### | |
## ------------------------------------------- ## | |
## QNAP NAS | |
## ------------------------------------------- ## | |
[[inputs.snmp]] | |
# List of agents to poll | |
agents = [ "XXX.XXX.XX.X" ] | |
interval = "15s" | |
timeout = "10s" | |
retries = 3 | |
version = 2 | |
community = "community" | |
max_repetitions = 10 | |
name = "snmp.QNAP" | |
# CPU | |
[[inputs.snmp.field]] | |
name = "name" | |
oid = "NAS-MIB::enclosureName.1" | |
[[inputs.snmp.table]] | |
name = "snmp.QNAP.cpuTable" | |
oid = "NAS-MIB::cpuTable" | |
[[inputs.snmp.table.field]] | |
name = "cpuIndex" | |
oid = "NAS-MIB::cpuIndex" | |
[[inputs.snmp.table.field]] | |
name = "cpuID" | |
oid = "NAS-MIB::cpuID" | |
[[inputs.snmp.table.field]] | |
name = "cpuUsage" | |
oid = "NAS-MIB::cpuUsage" | |
# Memory - Integers | |
[[inputs.snmp.field]] | |
name = "systemTotalMemEX" | |
oid = "NAS-MIB::systemTotalMemEX.0" | |
[[inputs.snmp.field]] | |
name = "systemFreeMemEX" | |
oid = "NAS-MIB::systemFreeMemEX.0" | |
# Uptime | |
[[inputs.snmp.field]] | |
name = "systemUptime" | |
oid = "NAS-MIB::systemUptimeEX.0" | |
# Temperature | |
[[inputs.snmp.field]] | |
name = "systemTemperature" | |
oid = "NAS-MIB::enclosureSystemTemp.1" | |
# Fan | |
[[inputs.snmp.table]] | |
name = "snmp.QNAP.systemFanTableEx" | |
oid = "NAS-MIB::systemFanTableEx" | |
[[inputs.snmp.table.field]] | |
name = "sysFanIndexEX" | |
oid = "NAS-MIB::sysFanIndexEX" | |
[[inputs.snmp.table.field]] | |
name = "sysFanDescrEX" | |
oid = "NAS-MIB::sysFanDescrEX" | |
[[inputs.snmp.table.field]] | |
name = "sysFanSpeedEX" | |
oid = "NAS-MIB::sysFanSpeedEX" | |
# Interfaces | |
[[inputs.snmp.table]] | |
name = "snmp.QNAP.systemIfTableEx" | |
oid = "NAS-MIB::systemIfTableEx" | |
[[inputs.snmp.table.field]] | |
name = "ifIndexEX" | |
oid = "NAS-MIB::ifIndexEX" | |
[[inputs.snmp.table.field]] | |
name = "ifDescrEX" | |
oid = "NAS-MIB::ifDescrEX" | |
[[inputs.snmp.table.field]] | |
name = "ifPacketsReceivedEX" | |
oid = "NAS-MIB::ifPacketsReceivedEX" | |
[[inputs.snmp.table.field]] | |
name = "ifPacketsSentEX" | |
oid = "NAS-MIB::ifPacketsSentEX" | |
[[inputs.snmp.table.field]] | |
name = "ifErrorPacketsEX" | |
oid = "NAS-MIB::ifErrorPacketsEX" | |
# Disk | |
[[inputs.snmp.table]] | |
name = "snmp.QNAP.systemHdTableEX" | |
oid = "NAS-MIB::systemHdTableEX" | |
[[inputs.snmp.table.field]] | |
name = "hdIndexEX" | |
oid = "NAS-MIB::hdIndexEX" | |
[[inputs.snmp.table.field]] | |
name = "hdDescrEX" | |
oid = "NAS-MIB::hdDescrEX" | |
[[inputs.snmp.table.field]] | |
name = "hdTemperatureEX" | |
oid = "NAS-MIB::hdTemperatureEX" | |
[[inputs.snmp.table.field]] | |
name = "hdStatusEX" | |
oid = "NAS-MIB::hdStatusEX" | |
[[inputs.snmp.table.field]] | |
name = "hdModelEX" | |
oid = "NAS-MIB::hdModelEX" | |
[[inputs.snmp.table.field]] | |
name = "hdSmartInfoEX" | |
oid = "NAS-MIB::hdSmartInfoEX" | |
# Volumes | |
[[inputs.snmp.table]] | |
name = "snmp.QNAP.systemVolumeTable" | |
oid = "NAS-MIB::systemVolumeTable" | |
[[inputs.snmp.table.field]] | |
name = "sysVolumeIndex" | |
oid = "NAS-MIB::sysVolumeIndex" | |
[[inputs.snmp.table.field]] | |
name = "sysVolumeDescr" | |
oid = "NAS-MIB::sysVolumeDescr" | |
[[inputs.snmp.table.field]] | |
name = "sysVolumeFS" | |
oid = "NAS-MIB::sysVolumeFS" | |
[[inputs.snmp.table.field]] | |
name = "sysVolumeTotalSize" | |
oid = "NAS-MIB::sysVolumeTotalSize" | |
[[inputs.snmp.table.field]] | |
name = "sysVolumeFreeSize" | |
oid = "NAS-MIB::sysVolumeFreeSize" | |
[[inputs.snmp.table.field]] | |
name = "sysVolumeStatus" | |
oid = "NAS-MIB::sysVolumeStatus" | |
# Disk Performance | |
[[inputs.snmp.table]] | |
name = "snmp.QNAP.diskPerformanceTable" | |
oid = "NAS-MIB::diskPerformanceTable" | |
[[inputs.snmp.table.field]] | |
name = "diskPerformanceIndex" | |
oid = "NAS-MIB::diskPerformanceIndex" | |
[[inputs.snmp.table.field]] | |
name = "blvID" | |
oid = "NAS-MIB::blvID" | |
[[inputs.snmp.table.field]] | |
name = "iops" | |
oid = "NAS-MIB::iops" | |
[[inputs.snmp.table.field]] | |
name = "latency" | |
oid = "NAS-MIB::latency" | |
## ------------------------------------------- ## | |
## CISCO SMART SWITCH | |
## ------------------------------------------- ## | |
[[inputs.snmp]] | |
agents = [ "XXX.XXX.XX.X" ] | |
interval = "15s" | |
timeout = "10s" | |
retries = 3 | |
version = 2 | |
community = "community" | |
max_repetitions = 10 | |
name = "snmp.CISCO" | |
alias = "cisco" | |
# hostname (main snmp.CISCO table) | |
[[inputs.snmp.field]] | |
name = "hostname" | |
oid = "SNMPv2-MIB::sysDescr.0" | |
# Instance Uptime (main snmp.CISCO table) | |
[[inputs.snmp.field]] | |
name = "sysUpTime" | |
oid = "DISMAN-EVENT-MIB::sysUpTimeInstance" | |
# Port statuses | |
[[inputs.snmp.field]] | |
name = "port1" | |
oid = "IF-MIB::ifOperStatus.49" | |
[[inputs.snmp.field]] | |
name = "port2" | |
oid = "IF-MIB::ifOperStatus.50" | |
[[inputs.snmp.field]] | |
name = "port3" | |
oid = "IF-MIB::ifOperStatus.51" | |
[[inputs.snmp.field]] | |
name = "port4" | |
oid = "IF-MIB::ifOperStatus.52" | |
[[inputs.snmp.field]] | |
name = "port5" | |
oid = "IF-MIB::ifOperStatus.53" | |
[[inputs.snmp.field]] | |
name = "port6" | |
oid = "IF-MIB::ifOperStatus.54" | |
[[inputs.snmp.field]] | |
name = "port7" | |
oid = "IF-MIB::ifOperStatus.55" | |
[[inputs.snmp.field]] | |
name = "port8" | |
oid = "IF-MIB::ifOperStatus.56" | |
[[inputs.snmp.field]] | |
name = "port9" | |
oid = "IF-MIB::ifOperStatus.57" | |
[[inputs.snmp.field]] | |
name = "port10" | |
oid = "IF-MIB::ifOperStatus.58" | |
[[inputs.snmp.field]] | |
name = "port11" | |
oid = "IF-MIB::ifOperStatus.59" | |
[[inputs.snmp.field]] | |
name = "port12" | |
oid = "IF-MIB::ifOperStatus.60" | |
[[inputs.snmp.field]] | |
name = "port13" | |
oid = "IF-MIB::ifOperStatus.61" | |
[[inputs.snmp.field]] | |
name = "port14" | |
oid = "IF-MIB::ifOperStatus.62" | |
[[inputs.snmp.field]] | |
name = "port15" | |
oid = "IF-MIB::ifOperStatus.63" | |
[[inputs.snmp.field]] | |
name = "port16" | |
oid = "IF-MIB::ifOperStatus.64" | |
[[inputs.snmp.field]] | |
name = "port17" | |
oid = "IF-MIB::ifOperStatus.65" | |
[[inputs.snmp.field]] | |
name = "port18" | |
oid = "IF-MIB::ifOperStatus.66" | |
[[inputs.snmp.field]] | |
name = "port19" | |
oid = "IF-MIB::ifOperStatus.67" | |
[[inputs.snmp.field]] | |
name = "port20" | |
oid = "IF-MIB::ifOperStatus.68" | |
[[inputs.snmp.field]] | |
name = "port21" | |
oid = "IF-MIB::ifOperStatus.69" | |
[[inputs.snmp.field]] | |
name = "port22" | |
oid = "IF-MIB::ifOperStatus.70" | |
[[inputs.snmp.field]] | |
name = "port23" | |
oid = "IF-MIB::ifOperStatus.71" | |
[[inputs.snmp.field]] | |
name = "port24" | |
oid = "IF-MIB::ifOperStatus.72" | |
## ------------------------------------------- ## | |
## PFSENSE | |
## ------------------------------------------- ## | |
[[inputs.snmp]] | |
agents = [ "XXX.XXX.XX.X" ] | |
interval = "15s" | |
timeout = "10s" | |
retries = 3 | |
version = 2 | |
community = "community" | |
max_repetitions = 10 | |
name = "snmp.PFSENSE" | |
alias = "pfsense" | |
# hostname (main snmp.CISCO table) | |
[[inputs.snmp.field]] | |
name = "hostname" | |
oid = "SNMPv2-MIB::sysName.0" | |
# is_tag = true | |
# Uptime (main snmp.CISCO table) | |
[[inputs.snmp.field]] | |
name = "sysUpTime" | |
oid = "HOST-RESOURCES-MIB::hrSystemUptime.0" | |
# Ports (main snmp.CISCO table) | |
# 1 - up | |
# 5 - dormant (unplugged) | |
# 2 - down | |
[[inputs.snmp.field]] | |
name = "port1" | |
oid = "IF-MIB::ifOperStatus.1" | |
[[inputs.snmp.field]] | |
name = "port2" | |
oid = "IF-MIB::ifOperStatus.2" | |
[[inputs.snmp.field]] | |
name = "port3" | |
oid = "IF-MIB::ifOperStatus.3" | |
[[inputs.snmp.field]] | |
name = "port4" | |
oid = "IF-MIB::ifOperStatus.4" | |
[[inputs.snmp.field]] | |
name = "port5" | |
oid = "IF-MIB::ifOperStatus.5" | |
[[inputs.snmp.field]] | |
name = "port6" | |
oid = "IF-MIB::ifOperStatus.6" | |
## ------------------------------------------- ## | |
## LOCAL (rPI) | |
## ------------------------------------------- ## | |
[[inputs.cpu]] | |
percpu = true | |
totalcpu = true | |
collect_cpu_time = false | |
report_active = false |