Last active
February 16, 2024 18:51
-
-
Save sakalauskas/2720f0e28f66ae878b794c4af4c07ec4 to your computer and use it in GitHub Desktop.
CWT-TH03S sensor esphome configuration
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
uart: | |
# id: mod_bus | |
tx_pin: GPIO1 | |
rx_pin: GPIO3 | |
# baud_rate: 19200 | |
baud_rate: 4800 | |
stop_bits: 1 | |
data_bits: 8 | |
parity: NONE | |
debug: | |
direction: BOTH | |
modbus: | |
flow_control_pin: 5 | |
id: modbus1 | |
send_wait_time: 1500ms | |
modbus_controller: | |
- id: temp | |
## the Modbus device addr | |
address: 1 | |
modbus_id: modbus1 | |
command_throttle: 100ms | |
setup_priority: -10 | |
update_interval: 3s | |
sensor: | |
- platform: modbus_controller | |
modbus_controller_id: temp | |
name: "Sauna Humidity" | |
id: sauna_humidity | |
device_class: humidity | |
register_type: holding | |
address: 0x0000 | |
unit_of_measurement: "%" | |
value_type: S_WORD | |
filters: | |
- multiply: 0.1 | |
state_class: measurement | |
- platform: modbus_controller | |
modbus_controller_id: temp | |
name: "Sauna Temperature" | |
id: sauna_temparature | |
register_type: holding | |
address: 0x0001 | |
unit_of_measurement: "°C" | |
value_type: S_WORD | |
device_class: temperature | |
filters: | |
- multiply: 0.1 | |
accuracy_decimals: 1 | |
state_class: measurement |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Hi! Please can you help me with errors. I use your configuration but it did not work now. My bord - keystudio esp32 plus
My configurration:
esphome:
name: esphome-web-c23d6c
friendly_name: Keystudio
esp32:
board: esp32dev
framework:
type: arduino
Enable logging
logger:
level: verbose
Enable Home Assistant API
api:
encryption:
key: "#####################"
ota:
wifi:
ssid: ##################
password: ###############
Enable fallback hotspot (captive portal) in case wifi connection fails
ap:
ssid: "Esphome-Web-C23D6C"
password: "################"
captive_portal:
uart:
id: modbus_uart
tx_pin: GPIO17
rx_pin: GPIO16
baud_rate: 4800
stop_bits: 1
data_bits: 8
parity: None
debug:
direction: BOTH
modbus:
id: modbus1
uart_id: modbus_uart
send_wait_time: 3000ms
modbus_controller:
the Modbus device addr
address: 0x01command_throttle: 100ms
setup_priority: -10
modbus_id: modbus1
update_interval: 3s
############ MODBUS ###################################################
platform: modbus_controller
modbus_controller_id: temp
name: "Humidity"
id: humidity
device_class: humidity
register_type: holding
address: 0x0000
#custom_command: [ 0x01, 0x03, 0x00, 0x00, 0x00, 0x02]
unit_of_measurement: "%"
value_type: S_WORD
filters:
state_class: measurement
platform: modbus_controller
modbus_controller_id: temp
name: "Temperature"
id: temparature
register_type: holding
address: 0x0001
#custom_command: [ 0x01, 0x03, 0x01, 0x00, 0x00, 0x02]
unit_of_measurement: "°C"
value_type: S_WORD
device_class: temperature
filters:
state_class: measurement
Logs with errors:
[20:39:43][V][modbus_controller:179]: 1 modbus commands already in queue
[20:39:43][V][modbus_controller:148]: Range : 0 Size: 2 (3) skip: 0
[20:39:43][W][modbus_controller:136]: Duplicate modbus command found: type=0x3 address=0 count=2
[20:39:44][V][modbus_controller:047]: Sending next modbus command to device 1 register 0x00 count 2
[20:39:44][V][modbus:199]: Modbus write: 01.03.00.00.00.02.C4.0B (8)
[20:39:44][V][modbus_controller:509]: Command sent 3 0x0 2
[20:39:44][D][uart_debug:114]: >>> 01:03:00:00:00:02:C4:0B
[20:39:44][V][modbus:042]: Modbus received Byte 1 (0X1)
[20:39:44][V][modbus:042]: Modbus received Byte 3 (0X3)
[20:39:44][V][modbus:042]: Modbus received Byte 0 (0X0)
[20:39:44][V][modbus:042]: Modbus received Byte 0 (0X0)
[20:39:44][V][modbus:042]: Modbus received Byte 0 (0X0)
[20:39:44][W][modbus:108]: Modbus CRC Check failed! F020!=00
[20:39:44][V][modbus:042]: Modbus received Byte 2 (0X2)
[20:39:44][V][modbus:042]: Modbus received Byte 196 (0Xc4)
[20:39:44][V][modbus:042]: Modbus received Byte 11 (0Xb)
[20:39:44][W][component:214]: Component modbus took a long time for an operation (0.05 s).
[20:39:44][W][component:215]: Components should block for at most 20-30ms.
[20:39:45][D][uart_debug:114]: <<< 01:03:00:00:00:02:C4:0B
[20:39:46][V][modbus_controller:179]: 1 modbus commands already in queue
[20:39:46][V][modbus_controller:148]: Range : 0 Size: 2 (3) skip: 0