* Copyright 2016 David Lomas (codersaur) | |
* | |
* Name: Fibaro Dimmer 2 (FGD-212) | |
* | |
* Author: David Lomas (codersaur) modified by steve bratt to fix android bug | |
* | |
* Date: 2016-10-11 | |
* | |
* Version: 1.01 | |
* | |
* Description: | |
* - This device handler is written specifically for the Fibaro Dimmer 2 (FGD-212). | |
* - It extends hajar97's original device handler to suport Nightmode and fixes a number of issues. | |
* - Nightmode function: | |
* Nightmode forces the dimmer to switch on at a specific level (e.g. low-level during the night). | |
* Nightmode can be enabled/disabled manually using the new Nightmode tile, and/or scheduled from the device settings. | |
* The 'Force Nightmode' option will cause the dimmer level will be adjusted immediately when Nightmode is enabled/disabled. | |
* | |
* Fibaro Dimmer 2 (FGD-212) physical device notes: | |
* - The auto-calibration feature will sometimes set parameter 1 too high. Use GetConfig to find out what values | |
* have been set by auto-calibration and adjust as necessary. | |
* - Sending level 0, will switch the dimmer off and does NOT change the level. | |
* | |
* Version History: | |
* | |
* 2016-10-11: v1.01 | |
* - Added Nightmode functionality. | |
* - dimmerEvents(): Fixed MeterGet requests after a switch or level state change. | |
* - on(), off(), setLevel(): Delayed switchMultilevelGet() requests by 8s as early requests generate erroneous | |
* data. The dimmer will send a correct report once it has completed the request anyway (which is usually sooner than 8s). | |
* - zwaveEvent(_MeterReport_): Removed rounding of power values. Also, Energy and power values are stored | |
* as dispEnergy and dispPower to work-around UI formatting issue. | |
* - Settings/Preferences: Fixed param24/25/27 to allow combination of options. | |
* - Simplified fingerprint. | |
* | |
* 2016-10-05: v1.00 | |
* - Initial version based on device handler by hajar97. | |
* - Tiles: Added GetConfig button to retreive the current device settings (which are displayed in the debug log). | |
* | |
* To Do: | |
* - Display load errors, e.g. burnt out bulb warnings. | |
* - Settings/Preferences: Fix Association Groups (atm, it just puts the controller into the relevent group). | |
* - Update the device settings in ST UI when configuration reports are received. | |
* [On Hold: This is not currently possible due to ST platform limitations. Device preferences are read-only!] | |
* | |
* License: | |
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except | |
* in compliance with the License. You may obtain a copy of the License at: | |
* | |
* http://www.apache.org/licenses/LICENSE-2.0 | |
* | |
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed | |
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License | |
* for the specific language governing permissions and limitations under the License. | |
* | |
**/ | |
metadata { | |
definition (name: "Fibaro Dimmer 2", namespace: "codersaur", author: "David Lomas") { | |
capability "Actuator" | |
capability "Switch" | |
capability "Switch Level" | |
capability "Sensor" | |
capability "Power Meter" | |
capability "Energy Meter" | |
capability "Polling" | |
capability "Refresh" | |
capability "Configuration" | |
command "reset" | |
command "configureAfterSecure" | |
command "changeSingleParamAfterSecure" | |
command "getConfigReport" | |
command "enableNightmode" | |
command "disableNightmode" | |
command "toggleNightmode" | |
command "test" | |
// Standard (Capability) Attributes: | |
attribute "switch", "string" | |
attribute "level", "number" | |
attribute "power", "number" | |
attribute "energy", "number" | |
// Custom Attributes: | |
attribute "scene", "number" | |
attribute "nightmode", "string" | |
attribute "lastReset", "string" // Time that ad hoc reporting was reset. | |
// Display Attributes: | |
// These are only required because the UI lacks number formatting and strips leading zeros. | |
attribute "dispPower", "string" | |
attribute "dispEnergy", "string" | |
// Fingerprint | |
//fingerprint deviceId: "0x1001", inClusters: "0x5E, 0x20, 0x86, 0x72, 0x26, 0x5A, 0x59, 0x85, 0x73, 0x98, 0x7A, 0x56, 0x70, 0x31, 0x32, 0x8E, 0x60, 0x75, 0x71, 0x27, 0x22, 0xEF, 0x2B" | |
fingerprint deviceId: "0x1001", inClusters: "0x5E, 0x20, 0x86, 0x26, 0x85, 0x59, 0x8E, 0x32, 0x31, 0x71" | |
} | |
// Simulator Metadata | |
simulator { | |
status "on": "command: 2003, payload: FF" | |
status "off": "command: 2003, payload: 00" | |
status "09%": "command: 2003, payload: 09" | |
status "10%": "command: 2003, payload: 0A" | |
status "33%": "command: 2003, payload: 21" | |
status "66%": "command: 2003, payload: 42" | |
status "99%": "command: 2003, payload: 63" | |
for (int i = 0; i <= 10000; i += 1000) { | |
status "power ${i} W": new physicalgraph.zwave.Zwave().meterV3.meterReport( | |
scaledMeterValue: i, precision: 3, meterType: 4, scale: 2, size: 4).incomingMessage() | |
} | |
for (int i = 0; i <= 100; i += 10) { | |
status "energy ${i} kWh": new physicalgraph.zwave.Zwave().meterV3.meterReport( | |
scaledMeterValue: i, precision: 3, meterType: 0, scale: 0, size: 4).incomingMessage() | |
} | |
["FF", "00", "09", "0A", "21", "42", "63"].each { val -> | |
reply "2001$val,delay 100,2602": "command: 2603, payload: $val" | |
} | |
} | |
// Tile Definitions: | |
tiles(scale: 2) { | |
// Multi Tile: | |
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){ | |
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") { | |
attributeState "on", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#79b821", nextState:"turningOff" | |
attributeState "off", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn" | |
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#79b821", nextState:"turningOff" | |
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn" | |
} | |
tileAttribute ("device.level", key: "SLIDER_CONTROL") { | |
attributeState "level", action:"switch level.setLevel" | |
} | |
} | |
// Instantaneous Values: | |
valueTile("instMode", "device.dispPower", decoration: "flat", width: 2, height: 1) { | |
state "default", label:'Now:', action:"refresh.refresh", icon: "https://raw.githubusercontent.com/codersaur/SmartThings/master/icons/tile_2x1_refresh.png" | |
} | |
valueTile("power", "device.dispPower", decoration: "flat", width: 2, height: 1) { | |
state "default", label:'${currentValue}', icon: "https://raw.githubusercontent.com/codersaur/SmartThings/master/icons/tile_2x1_top_bottom_2.png" | |
} | |
// Ad Hoc Energy Stats: | |
valueTile("lastReset", "device.lastReset", decoration: "flat", width: 2, height: 1) { | |
state "default", label:'Since: ${currentValue}', action:"reset", icon: "https://raw.githubusercontent.com/codersaur/SmartThings/master/icons/tile_2x1_stopwatch_reset.png" | |
} | |
valueTile("energy", "device.dispEnergy", width: 2, height: 1) { | |
state "default", label:'${currentValue}', icon: "https://raw.githubusercontent.com/codersaur/SmartThings/master/icons/tile_2x1_top_bottom_2.png" | |
} | |
// Other Tiles: | |
standardTile("nightmode", "device.nightmode", decoration: "flat", width: 2, height: 2) { | |
state "default", label:'${currentValue}', action:"toggleNightmode", icon:"st.Weather.weather4" | |
} | |
standardTile("configureAfterSecure", "device.configure", inactiveLabel: false, decoration: "flat", width: 2, height: 2) { | |
state "configure", label:'', action:"configureAfterSecure", icon:"st.secondary.configure" | |
} | |
standardTile("getConfig", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) { | |
state "default", label:'Get Config', action:"getConfigReport" | |
} | |
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) { | |
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh" | |
} | |
standardTile("test", "device.power", decoration: "flat", width: 2, height: 2) { | |
state "default", label:'Test', action:"test" | |
} | |
// Tile Layouts: | |
main(["switch","power","energy"]) | |
details(["switch","instMode","power","nightmode","lastReset","energy","configureAfterSecure","getConfig","refresh"]) | |
} | |
preferences { | |
section { // NIGHTMODE: | |
def paragraph = "NIGHTMODE:\n\nNightmode forces the dimmer to switch on at a specific level (e.g. low-level during the night).\n" + | |
"Nightmode can be enabled/disabled manually using the new Nightmode tile, or scheduled below.\n" + | |
"When nightmode is disabled, the dimmer's original settings are restored." | |
input name: "configNightmodeLevel", type: "number", range: "1..99", required: true, | |
title: paragraph + "\n\n" + | |
"1. Nightmode Level: The dimmer will always switch on at this level during nightmode." | |
input name: "configNightmodeForce", type: "boolean", required: true, | |
title: "2. Force Nightmode: If the dimmer is on when nightmode is enabled, the Nightmode Level is applied immediately " + | |
"(otherwise it's only applied next time the dimmer is switched on)." | |
input name: "configNightmodeStartTime", type: "time", required: false, | |
title: "Nightmode Start Time: Nightmode will start every day at this time." | |
input name: "configNightmodeStopTime", type: "time", required: false, | |
title: "Nightmode Stop Time: Nightmode will stop every day at this time." | |
} | |
section { // GENERAL: | |
// Debug Mode: | |
input name: "configDebugMode", type: "boolean", title: "GENERAL:\n\nEnable debug logging?", required: false | |
} | |
section { // DEVICE PARAMETERS: | |
def paragraph = "DEVICE PARAMETERS:\n\nGROUP 0 - The Dimmer 2 behavior - Basic functionalities" | |
input name: "param1", type: "number", range: "1..98", required: true, | |
title: paragraph + "\n\n" + | |
"1. Minimum brightness level. " + | |
"This parameter is set automatically during the calibration process. " + | |
"The parameter can be changed manually after the calibration.\n" + | |
"Available settings: 1-98 - percentage level of brightness.\n" + | |
"Default value: 1." | |
input name: "param2", type: "number", range: "2..99", required: true, | |
title: "2. Maximum brightness level. " + | |
"This parameter is set automatically during the calibration process. " + | |
"The parameter can be changed manually after the calibration.\n" + | |
"Available settings: 2-99 - percentage level of brightness.\n" + | |
"Default value: 99." | |
input name: "param3", type: "number", range: "1..99", required: true, | |
title: "3. Incandescence level of dimmable compact fluorescent lamps. " + | |
"Virtual value set as a percentage level between parameters MIN (1%) and MAX (99%). " + | |
"The Dimmer 2 will set to this value after first switch on. " + | |
"It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.\n" + | |
"Available settings: 1-99 - percentage level of brightness.\n" + | |
"Default value: 1." | |
input name: "param4", type: "number", range: "0..255", required: true, | |
title: "4. Incandescence time of dimmable compact fluorescent lamps. " + | |
"This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. " + | |
"Setting this parameter to 0 will disable the incandescence functionality.\n" + | |
"Available settings: 0-255 (0-25.5s).\n" + | |
"Default value: 0." | |
input name: "param5", type: "number", range: "1..99", required: true, | |
title: "5. Automatic control - dimming step size. " + | |
"This parameter defines the percentage value of dimming step during the automatic control.\n" + | |
"Available settings: 1-99 - dimming step percentage value.\n" + | |
"Default value: 1." | |
input name: "param6", type: "number", range: "0..255", required: true, | |
title: "6. Automatic control - time of a dimming step. " + | |
"This parameter defines the time of single dimming step set in parameter 5 during the automatic control.\n" + | |
"Available settings: 0-255 (0-2.55s, in 10ms steps).\n" + | |
"Default value: 1." | |
input name: "param7", type: "number", range: "1..99", required: true, | |
title: "7. Manual control - dimming step size. " + | |
"This parameter defines the percentage value of dimming step during the manual control.\n" + | |
"Available settings: 1-99 - dimming step percentage value.\n" + | |
"Default value: 1." | |
input name: "param8", type: "number", range: "0..255", required: true, | |
title: "8. Manual control - time of a dimming step. " + | |
"This parameter defines the time of single dimming step set in parameter 7 during the manual control.\n" + | |
"Available settings: 0-255 (0-2.55s, in 10ms steps).\n" + | |
"Default value: 5." | |
input name: "param9", type: "number", range: "0..1", required: true, | |
title: "9. State of the device after a power failure. " + | |
"The Dimmer 2 will return to the last state before power failure.\n" + | |
"Available settings:\n" + | |
"0 = the Dimmer 2 does not save the state before a power failure, it returns to �off� position,\n" + | |
"1 = the Dimmer 2 restores its state before power failure.\n" + | |
"Default value: 1." | |
input name: "param10", type: "number", range: "0..32767", required: true, | |
title: "10. Timer functionality (auto - off). " + | |
"This parameter allows to automatically switch off the device after specified time from switching on the light source. " + | |
"It may be useful when the Dimmer 2 is installed in the stairway.\n" + | |
"Available settings: 0 - Function disabled,\n1-32767 - time to turn off measured in seconds (1s-9.1h).\n" + | |
"Default value: 0." | |
input name: "param11", type: "enum", required: true, | |
options: ["0" : "0", | |
"1" : "1", | |
"2" : "2", | |
"255" : "255"], | |
title: "11. ALL ON/ALL OFF function. " + | |
"Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct range of the main controller.\n" + | |
"Available settings:\n" + | |
"0 = All ON not active, All OFF not active,\n" + | |
"1 = All ON not active, All OFF active,\n" + | |
"2 = All ON active, All OFF not active,\n" + | |
"255 = All ON active, All OFF active.\n" + | |
"Default value: 255." | |
input name: "param13", type: "number", range: "0..2", required: true, | |
title: "13. Force auto-calibration. " + | |
"Changing value of this parameter will force the calibration process. " + | |
"During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.\n" + | |
"Available settings:\n" + | |
"0 = readout,\n" + | |
"1 = force auto-calibration of the load without FIBARO Bypass 2,\n" + | |
"2 = force auto-calibration of the load with FIBARO Bypass 2.\n" + | |
"Default value: 0." | |
input name: "param15", type: "number", range: "0..99", required: true, | |
title: "15. Burnt out bulb detection. " + | |
"Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR.\n" + | |
"Available settings:\n0 - function disabled,\n" + | |
"1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb).\n" + | |
"Default value: 30." | |
input name: "param16", type: "number", range: "0..255", required: true, | |
title: "16. Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection. " + | |
"Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer 2).\n" + | |
"Available settings:\n0 - detection of a burnt out bulb disabled,\n1-255 - delay time in seconds.\n" + | |
"Default value: 5." | |
input name: "param19", type: "number", range: "0..99", required: true, | |
title: "19. Forced switch on brightness level. " + | |
"If the parameter is active, switching on the Dimmer 2 (S1 single click) will always set this brightness level.\n" + | |
"Available settings:\n0 - function disabled,\n1-99 - percentage level of brightness.\n" + | |
"Default value: 0." | |
paragraph = "GROUP 20 - Dimmer 2 operation - Switches" | |
input name: "param20", type: "number", range: "0..2", required: true, | |
title: paragraph + "\n\n" + | |
"20. Switch type. " + | |
"Choose between momentary, toggle and roller blind switch.\n" + | |
"Available settings:\n" + | |
"0 = momentary switch,\n1 = toggle switch,\n2 = roller blind switch - two switches operate the Dimmer 2 (S1 to brighten, S2 to dim).\n" + | |
"Default value: 0." | |
input name: "param21", type: "number", range: "0..1", required: true, | |
title: "21. The value sent to associated devices on single click. " + | |
"This parameter defines the value sent to devices associated with Dimmer 2 after its enabling.\n" + | |
"Available settings:\n" + | |
"0 = 0xFF value is sent, which will set associated devices to their last saved state,\n" + | |
"1 = current Dimmer 2 state is sent, which will synchronize brightness level of associated devices (other dimmers for example).\n" + | |
"Default value: 0." | |
input name: "param22", type: "number", range: "0..1", required: true, | |
title: "22. Assign toggle switch status to the device status. " + | |
"By default each change of toggle switch position results in action of Dimmer 2 (switch on/off) regardless the physical connection of contacts.\n" + | |
"Available settings:\n" + | |
"0 = device changes status on switch status change,\n1 = device status is synchronized with switch status.\n" + | |
"Default value: 0." | |
input name: "param23", type: "number", range: "0..1", required: true, | |
title: "23. Double click option - set the brightness level to MAX.\n" + | |
"Available settings:\n" + | |
"0 = double click disabled,\n" + | |
"1 = double click enabled.\n" + | |
"Default value: 1." | |
input name: "param24", type: "number", range: "0..31", required: true, | |
title: "24. Command frames sent in 2nd and 3rd association groups (S1 associations). " + | |
"Parameter determines, which actions will not result in sending frames to association groups.\n" + | |
"Available settings (add together):\n" + | |
"0 = all actions send to association groups,\n" + | |
"1 = do not send when switching ON (single click),\n" + | |
"2 = do not send when switching OFF (single click),\n" + | |
"4 = do not send when changing dimming level (holding and releasing),\n" + | |
"8 = do not send on double click,\n" + | |
"16 = send 0xFF value on double click.\n" + | |
"Default value: 0." | |
input name: "param25", type: "number", range: "0..31", required: true, | |
title: "25. Command frames sent in 4th and 5th association groups (S2 associations). " + | |
"Parameter determines, which actions will not result in sending frames to association groups.\n" + | |
"Available settings (add together):\n" + | |
"0 = all actions send to association groups,\n" + | |
"1 = do not send when switching ON (single click),\n" + | |
"2 = do not send when switching OFF (single click),\n" + | |
"4 = do not send when changing dimming level (holding and releasing),\n" + | |
"8 = do not send on double click,\n" + | |
"16 = send 0xFF value on double click.\n" + | |
"Default value: 0." | |
input name: "param26", type: "number", range: "0..1", required: true, | |
title: "26. The function of 3-way switch. " + | |
"Switch no. 2 controls the Dimmer 2 additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch).\n" + | |
"Available settings:\n" + | |
"0 = 3-way switch function for S2 disabled,\n" + | |
"1 = 3-way switch function for S2 enabled.\n" + | |
"Default value: 0." | |
input name: "param27", type: "number", range: "0..15", required: true, | |
title: "27. Associations in Z-Wave network security mode. " + | |
"This parameter defines how commands are sent in specified association groups: as secure or non-secure. " + | |
"Parameter is active only in Z-Wave network security mode. It does not apply to 1st lifeline group.\n" + | |
"Available settings (add together):\n" + | |
"0 = all groups (II-V) sent as non-secure,\n" + | |
"1 = 2nd group sent as secure,\n" + | |
"2 = 3rd group sent as secure,\n" + | |
"4 = 4th group sent as secure,\n" + | |
"8 = 5th group sent as secure,\n" + | |
"E.g. 15 = all groups (II-V) sent as secure.\n" + | |
"Default value: 15." | |
input name: "param28", type: "number", range: "0..1", required: true, | |
title: "28. Scene activation functionality.\n" + | |
"Available settings:\n" + | |
"0 = functionality deactivated,\n" + | |
"1 = functionality activated.\n" + | |
"Default value: 0.\n\n" + | |
"SCENE ID depends on the switch type configurations.\n" + | |
"Momentary switches:\n" + | |
"SCENE ID: S1 input:\n\t16 : 1 x click\n\t14 : 2 x click\n\t-- : 3 x click\n\t12 : hold\n\t13 : release\n" + | |
"SCENE ID: S2 input:\n\t26 : 1 x click\n\t24 : 2 x click\n\t25 : 3 x click\n\t22 : hold\n\t23 : release\n\n" + | |
"Toggle switches:\n" + | |
"SCENE ID: S1 input:\n\t10 : OFF to ON\n\t11 : ON to OFF\n\t14 : 2 x click\n\t-- : 3 x click\n" + | |
"SCENE ID: S2 input:\n\t20 : OFF to ON\n\t21 : ON to OFF\n\t24 : 2 x click\n\t25 : 3 x click\n\n" + | |
"Roller blinds switches:\n" + | |
"SCENE ID: S1 input:\n\t10 : turn ON (1 x click)\n\t13 : release\n\t14 : 2 x click\n\t-- : 3 x click\n\t17 : brightening\n" + | |
"SCENE ID: S2 input:\n\t11 : turn OFF (1 x click)\n\t13 : release\n\t14 : 2 x click\n\t15 : 3 x click\n\t18 : dimming" | |
input name: "param29", type: "number", range: "0..1", required: true, | |
title: "29. Switch functionality of S1 and S2. " + | |
"This parameter allows for switching the role of keys connected to S1 and S2 without changes in connection.\n" + | |
"Available settings:\n" + | |
"0 = standard mode,\n" + | |
"1 = S1 operates as S2, S2 operates as S1.\n" + | |
"Default value: 0." | |
paragraph = "GROUP 30 - Dimmer 2 operation - Advanced functionality" | |
input name: "param30", type: "number", range: "0..2", required: true, | |
title: paragraph + "\n\n" + | |
"30. Load control mode. " + | |
"This parameter allows to set the desired load control mode. " + | |
"The de- vice automatically adjusts correct control mode, but the installer may force its change using this parameter. " + | |
"Forced auto-calibration will set this parameter�s value to 2.\n" + | |
"Available settings:\n" + | |
"0 = forced leading edge control,\n" + | |
"1 = forced trailing edge control,\n" + | |
"2 = control mode selected automatically (based on auto-calibration).\n" + | |
"Default value: 2." | |
input name: "param32", type: "number", range: "0..2", required: true, | |
title: "32. On/Off mode. " + | |
"This mode is necessary while connecting non-dimmable light sources. " + | |
"Setting this parameter to 1 automatically ignores brightening/dimming time settings. " + | |
"Forced auto-calibration will set this parameter�s value to 2.\n" + | |
"Available settings:\n" + | |
"0 = on/off mode disabled (dimming is possible),\n" + | |
"1 = on/off mode enabled (dimming is not possible),\n" + | |
"2 = mode selected automatically.\n" + | |
"Default value: 2." | |
input name: "param34", type: "number", range: "0..2", required: true, | |
title: "34. Soft-Start functionality. " + | |
"Time required to warm up the lament of halogen bulb.\n" + | |
"Available settings:\n" + | |
"0 = no soft-start,\n" + | |
"1 = short soft-start (0.1s),\n" + | |
"2 = long soft-start (0.5s).\n" + | |
"Default value: 1." | |
input name: "param35", type: "number", range: "0..4", required: true, | |
title: "35. Auto-calibration after power on. " + | |
"This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.\n" + | |
"Available settings:\n" + | |
"0 = No auto-calibration of the load after power on,\n" + | |
"1 = Auto-calibration performed after first power on,\n" + | |
"2 = Auto-calibration performed after each power on,\n" + | |
"3 = Auto-calibration performed after first power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent),\n" + | |
"4 = Auto-calibration performed after each power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent).\n" + | |
"Default value: 1." | |
input name: "param37", type: "number", range: "0..1", required: true, | |
title: "37. Behaviour of the Dimmer 2 after OVERCURRENT or SURGE. " + | |
"Occuring of errors related to surge or overcurrent results in turning off the output to prevent possible malfunction. " + | |
"By default the device performs three attempts to turn on the load (useful in case of momentary, short failures of the power supply).\n" + | |
"Available settings:\n" + | |
"0 = device permanently disabled until re-ena- bling by command or external switch,\n" + | |
"1 = three attempts to turn on the load.\n" + | |
"Default value: 1." | |
input name: "param39", type: "number", range: "0..350", required: true, | |
title: "39. Power limit - OVERLOAD. " + | |
"Reaching the defined value will result in turning off the load. " + | |
"Additional apparent power limit of 350VA is active by default.\n" + | |
"Available settings:\n0 - functionality disabled,\n1-350 - 1-350W.\n" + | |
"Default value: 250." | |
paragraph = "GROUP 40 - Dimmer 2 operation - Alarms" | |
input name: "param40", type: "number", range: "0..3", required: true, | |
title: paragraph + "\n\n" + | |
"40. Response to General Purpose Alarm.\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Turn on the load,\n" + | |
"2 = Turn off the load,\n" + | |
"3 = Load blinking.\n" + | |
"Default value: 3." | |
input name: "param41", type: "number", range: "0..3", required: true, | |
title: "41. Response to Water Flooding Alarm.\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Turn on the load,\n" + | |
"2 = Turn off the load,\n" + | |
"3 = Load blinking.\n" + | |
"Default value: 2." | |
input name: "param42", type: "number", range: "0..3", required: true, | |
title: "42. Response to Smoke, CO or CO2 Alarm.\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Turn on the load,\n" + | |
"2 = Turn off the load,\n" + | |
"3 = Load blinking.\n" + | |
"Default value: 3." | |
input name: "param43", type: "number", range: "0..3", required: true, | |
title: "43. Response to Temperature Alarm.\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Turn on the load,\n" + | |
"2 = Turn off the load,\n" + | |
"3 = Load blinking.\n" + | |
"Default value: 1." | |
input name: "param44", type: "number", range: "1..32767", required: true, | |
title: "44. Time of alarm state.\n" + | |
"Available settings: 1-32767 (1-32767 seconds).\n" + | |
"Default value: 600." | |
paragraph = "Alarm settings - reports" | |
input name: "param45", type: "number", range: "0..1", required: true, | |
title: paragraph + "\n\n" + | |
"45. OVERLOAD alarm report (load power consumption too high).\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Send an alarm frame.\n" + | |
"Default value: 1." | |
input name: "param46", type: "number", range: "0..1", required: true, | |
title: "46. LOAD ERROR alarm report (no load, load failure, burnt out bulb).\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Send an alarm frame.\n" + | |
"Default value: 1." | |
input name: "param47", type: "number", range: "0..1", required: true, | |
title: "47. OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent).\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Send an alarm frame.\n" + | |
"Default value: 1." | |
input name: "param48", type: "number", range: "0..1", required: true, | |
title: "48. SURGE alarm report (Dimmer 2 output overvoltage).\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Send an alarm frame.\n" + | |
"Default value: 1." | |
input name: "param49", type: "number", range: "0..1", required: true, | |
title: "49. OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report.\n" + | |
"Available settings:\n" + | |
"0 = No reaction,\n" + | |
"1 = Send an alarm frame.\n" + | |
"Default value: 1." | |
paragraph = "GROUP 50 - Active power and energy reports" | |
input name: "param50", type: "number", range: "0..100", required: true, | |
title: paragraph + "\n\n" + | |
"50. Active power reports. " + | |
"The parameter defines the power level change that will result in a new power report being sent. " + | |
"The value is a percentage of the previous report.\n" + | |
"Available settings:\n0 - power reports disabled,\n1-100 (1-100%) - power report threshold.\n" + | |
"Default value: 10." | |
input name: "param52", type: "number", range: "0..32767", required: true, | |
title: "52. Periodic active power and energy reports. " + | |
"Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report.\n" + | |
"Available settings:\n0 - periodic reports disabled,\n1-32767 (1-32767 seconds).\n" + | |
"Default value: 3600." | |
input name: "param53", type: "number", range: "0..255", required: true, | |
title: "53. Energy reports. " + | |
"Energy level change which will result in sending a new energy report.\n" + | |
"Available settings:\n0 - energy reports disabled,\n1-255 (0.01-2.55 kWh) - report triggering threshold.\n" + | |
"Default value: 10." | |
input name: "param54", type: "number", range: "0..1", required: true, | |
title: "54. Self-measurement. " + | |
"The Dimmer 2 may include active power and energy consumed by itself in reports sent to the main controller.\n" + | |
"Available settings:\n" + | |
"0 = Self-measurement inactive,\n" + | |
"1 = Self-measurement active.\n" + | |
"Default value: 0." | |
input name: "param58", type: "number", range: "0..2", required: true, | |
title: "58. Method of calculating the active power. This parameter defines how to calculate active power. " + | |
"It is useful in a case of 2-wire connection with light sources other than resistive.\n" + | |
"Available settings:\n" + | |
"0 = measurement based on the standard algorithm,\n" + | |
"1 = approximation based on the calibration data,\n" + | |
"2 = approximation based on the control angle.\n" + | |
"Default value: 0." | |
input name: "param59", type: "number", range: "0..500", required: true, | |
title: "59. Approximated power at the maximum brightness level. " + | |
"This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level.\n" + | |
"Available settings: 0-500 (0-500W) - power consumed by the load at the maximum brightness level.\n" + | |
"Default value: 0." | |
input name: "paramAssociationGroup1", type: "bool", required: true, | |
title: "The Dimmer 2 provides the association of five groups.\n\n" + | |
"1st Association Group �Lifeline�,\n" + | |
"Default value: true" | |
input name: "paramAssociationGroup2", type: "bool", required: true, | |
title: "2nd Association Group �On/Off (S1)�,\n" + | |
"Default value: true" | |
input name: "paramAssociationGroup3", type: "bool", required: true, | |
title: "3rd Association Group �Dimmer (S1)�,\n" + | |
"Default value: false" | |
input name: "paramAssociationGroup4", type: "bool", required: true, | |
title: "4th Association Group �On/Off (S2)�,\n" + | |
"Default value: false" | |
input name: "paramAssociationGroup5", type: "bool", required: true, | |
title: "5th Association Group �Dimmer (S2)�.\n" + | |
"Default value: false" | |
} | |
} | |
} | |
/********************************************************************** | |
* Z-wave Event Handlers. | |
**********************************************************************/ | |
/** | |
* parse() - Called when messages from a device are received by the hub. | |
* | |
* The parse method is responsible for interpreting those messages and returning Event definitions. | |
* | |
* String description - The message from the device. | |
**/ | |
def parse(String description) { | |
if (state.debug) log.debug "${device.displayName}: parse(): Raw command: ${description}" | |
def result = null | |
if (description != "updated") { | |
// zwave.parse: The second parameter specifies which command version to return for each command type: | |
// FGD-212 supports: | |
// COMMAND_CLASS_BASIC [0x20: 1] | |
// COMMAND_CLASS_SWITCH_BINARY [0x25: 1] | |
// COMMAND_CLASS_SCENE_ACTIVATION [0x2B: 1] | |
// COMMAND_CLASS_METER_V3 [0x32: 3] | |
// COMMAND_CLASS_CONFIGURATION [0x70: 1] | |
// ... | |
def cmd = zwave.parse(description.replace("98C1", "9881"), [0x20: 1, 0x25: 1, 0x26: 3, 0x28: 1, 0x2B: 1, 0x30: 1, 0x32: 3, 0x70: 1, 0x72: 1, 0x73: 1, 0x85: 2, 0x90: 1, 0x98: 1, 0x9B: 1]) | |
// The purpose of the replace statement here is to fix a bug, see here: https://community.smartthings.com/t/wireless-wall-switch-zme-wallc-s-to-control-smartthings-devices-and-routines/24810/28 | |
if (cmd) { | |
result = zwaveEvent(cmd) | |
} | |
} | |
if (state.debug) log.debug "Parsed '${description}' to ${result.inspect()}" | |
return result | |
} | |
/** | |
* COMMAND_CLASS_BASIC (0x20) | |
* | |
* Short value 0xFF for on, 0x00 for off | |
**/ | |
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) { | |
log.trace "${device.displayName}: Switch Basic Report received: ${cmd}" | |
dimmerEvents(cmd) | |
} | |
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) { | |
log.trace "${device.displayName}: Switch Basic Set received: ${cmd}" | |
//dimmerEvents(cmd) | |
} | |
/** | |
* COMMAND_CLASS_SWITCH_BINARY (0x25) | |
* | |
* Short value 0xFF for on, 0x00 for off | |
**/ | |
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd) | |
{ | |
log.trace "${device.displayName}: Switch Binary Report received: ${cmd}" | |
dimmerEvents(cmd) | |
} | |
/** | |
* COMMAND_CLASS_SWITCH_MULTILEVEL (0x26) | |
* | |
* Short value 0x00 for off, other values are level (on). | |
* List<Short> payload | |
**/ | |
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv3.SwitchMultilevelReport cmd) { | |
log.trace "${device.displayName}: Switch Multilevel Report received: ${cmd}" | |
dimmerEvents(cmd) | |
} | |
/** | |
* dimmerEvents(): | |
* | |
* Common handler for BasicReport, SwitchBinaryReport, SwitchMultilevelReport. | |
* | |
* Requests a Meter Report if there has been a change. | |
**/ | |
def dimmerEvents(physicalgraph.zwave.Command cmd) { | |
def result = [] | |
def isStateChange | |
def value = (cmd.value ? "on" : "off") | |
def switchEvent = createEvent(name: "switch", value: value, descriptionText: "$device.displayName was turned $value") | |
result << switchEvent | |
isStateChange = switchEvent.isStateChange | |
if (cmd.value) { | |
def levelEvent = createEvent(name: "level", value: cmd.value, unit: "%") | |
result << levelEvent | |
isStateChange = (switchEvent.isStateChange || levelEvent.isStateChange) | |
} | |
if (isStateChange) { | |
if (state.debug) log.debug "${device.displayName}: dimmerEvents(): State changed, so checking for pending level and requesting meter report." | |
def pendingCmd = ((value == "on") ? checkNightmode() : []) // Only restore pending level if dimmer is switching on. | |
result << response(pendingCmd + ["delay 5000", secure(zwave.meterV3.meterGet(scale: 2)),"delay 10000", secure(zwave.meterV3.meterGet(scale: 2))]) | |
// Meter request is delayed for 5s, although sometimes this isn't long enough, so make a second request after another 10 seconds. | |
} | |
return result | |
} | |
/** | |
* COMMAND_CLASS_SCENE_ACTIVATION (0x2B) | |
* | |
* Short dimmingDuration | |
* Short sceneId | |
* List<Short> payload | |
* | |
* String format() | |
* | |
**/ | |
def zwaveEvent(physicalgraph.zwave.commands.sceneactivationv1.SceneActivationSet cmd) { | |
log.trace "${device.displayName}: Scene Activation: ${cmd}" | |
sendEvent(name: "scene", value: "$cmd.sceneId", data: [switchType: "$settings.param20"], descriptionText: "Scene id $cmd.sceneId was activated", isStateChange: true) | |
} | |
/** | |
* COMMAND_CLASS_METER_V3 (0x32) | |
* | |
* FGD-212 supports energy and power only. Will not report current, voltage, or power factor. | |
* | |
* Integer deltaTime Time in seconds since last report | |
* Short meterType Unknown = 0, Electric = 1, Gas = 2, Water = 3 | |
* List<Short> meterValue Meter value as an array of bytes | |
* Double scaledMeterValue Meter value as a double | |
* List<Short> previousMeterValue Previous meter value as an array of bytes | |
* Double scaledPreviousMeterValue Previous meter value as a double | |
* Short size The size of the array for the meterValue and previousMeterValue | |
* Short scale The scale of the values: "kWh"=0, "kVAh"=1, "Watts"=2, "pulses"=3, "Volts"=4, "Amps"=5, "Power Factor"=6, "Unknown"=7 | |
* Short precision The decimal precision of the values | |
* Short rateType ??? | |
* Boolean scale2 ??? | |
* | |
**/ | |
def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd) { | |
log.trace "${device.displayName}: Meter Report received: ${cmd}" | |
if (cmd.meterType == 1) { | |
if (cmd.scale == 0) { | |
// Accumulated Energy (kWh) | |
state.energy = cmd.scaledMeterValue | |
sendEvent(name: "dispEnergy", value: String.format("%.2f",cmd.scaledMeterValue as BigDecimal) + " kWh", displayed: false) | |
return createEvent(name: "energy", value: cmd.scaledMeterValue, unit: "kWh") | |
} else if (cmd.scale == 1) { | |
// Accumulated Energy (kVAh) - Ignored | |
//sendEvent(name: "dispEnergy", value: String.format("%.2f",cmd.scaledMeterValue as BigDecimal) + " kVAh", displayed: false) | |
//return createEvent(name: "energy", value: cmd.scaledMeterValue, unit: "kVAh") | |
} else if (cmd.scale == 2) { | |
// Instantaneous Power (Watts) | |
sendEvent(name: "dispPower", value: String.format("%.1f",cmd.scaledMeterValue as BigDecimal) + " W", displayed: false) | |
return createEvent(name: "power", value: cmd.scaledMeterValue, unit: "W") | |
} else if (cmd.scale == 4) { | |
// Instantaneous Voltage (Volts) - Not supported by the FGD-212. | |
//sendEvent(name: "dispVoltage", value: String.format("%.1f",cmd.scaledMeterValue as BigDecimal) + " V", displayed: false) | |
//return createEvent(name: "voltage", value: cmd.scaledMeterValue, unit: "V") | |
} else if (cmd.scale == 5) { | |
// Instantaneous Current (Amps) - Not supported by the FGD-212. | |
//sendEvent(name: "dispCurrent", value: String.format("%.1f",cmd.scaledMeterValue as BigDecimal) + " A", displayed: false) | |
//return createEvent(name: "current", value: cmd.scaledMeterValue, unit: "A") | |
} else if (cmd.scale == 6) { | |
// Instantaneous Power Factor - Not supported by the FGD-212. | |
//sendEvent(name: "dispPowerFactor", value: "PF: " + String.format("%.2f",cmd.scaledMeterValue as BigDecimal), displayed: false) | |
//return createEvent(name: "powerFactor", value: cmd.scaledMeterValue, unit: "PF") | |
} else { | |
// Unknown Meter Report Scale: | |
log.warn "${device.displayName}: zwaveEvent(): Unhandled Meter Report: Scale: ${cmd.scale}" | |
} | |
} | |
} | |
/** | |
* COMMAND_CLASS_CONFIGURATION (0x70) | |
* | |
* Log received configuration values. | |
**/ | |
def zwaveEvent(physicalgraph.zwave.commands.configurationv1.ConfigurationReport cmd) { | |
log.trace "${device.displayName}: Configuration Report received: ${cmd}" | |
// Translate configurationValue (byte array) back to scaledConfigurationValue (double): | |
// This should be done in zwave.parse() but isn't implemented yet. | |
// See: https://community.smartthings.com/t/zwave-configurationv2-configurationreport-dev-question/9771 | |
def scValue = 0 | |
if (cmd.size == 1) { scValue = cmd.configurationValue[0]} | |
else if (cmd.size == 2) { scValue = cmd.configurationValue[1] + (cmd.configurationValue[0] * 0x100) } | |
else if (cmd.size == 3) { scValue = cmd.configurationValue[2] + (cmd.configurationValue[1] * 0x100) + (cmd.configurationValue[0] * 0x10000) } | |
else if (cmd.size == 4) { scValue = cmd.configurationValue[3] + (cmd.configurationValue[2] * 0x100) + (cmd.configurationValue[1] * 0x10000) + (cmd.configurationValue[0] * 0x1000000) } | |
// Cache param19 as it's needed for nightmode: | |
if ( 19 == cmd.parameterNumber.toInteger()) state.preferencesCache_param19 = scValue | |
} | |
/** | |
* securityv1.SecurityMessageEncapsulation (0x98) | |
* | |
* List<Short> commandByte | |
* Short commandClassIdentifier | |
* Short commandIdentifier | |
* Boolean secondFrame | |
* Short sequenceCounter | |
* Boolean sequenced | |
* List<Short> payload | |
* | |
* String format() | |
* | |
* Devices that support the Security command class can send messages in an encrypted form; | |
* they arrive wrapped in a SecurityMessageEncapsulation command and must be unencapsulated | |
**/ | |
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) { | |
log.trace(cmd) | |
def encapsulatedCommand = cmd.encapsulatedCommand([0x20: 1, 0x25: 1, 0x26: 3, 0x28: 1, 0x2B: 1, 0x30: 1, 0x32: 3, 0x70: 1, 0x72: 1, 0x73: 1, 0x85: 2, 0x90: 1, 0x98: 1, 0x9B: 1]) // can specify command class versions here like in zwave.parse | |
if (encapsulatedCommand) { | |
return zwaveEvent(encapsulatedCommand) | |
} else { | |
log.warn "Unable to extract encapsulated cmd from $cmd" | |
createEvent(descriptionText: cmd.toString()) | |
} | |
} | |
/** | |
* Default event handler. | |
* | |
* Called for all events that aren't handled above. | |
**/ | |
def zwaveEvent(physicalgraph.zwave.Command cmd) { | |
log.warn "${device.displayName}: No handler for command: $cmd" | |
// Handles all Z-Wave commands we aren't interested in | |
createEvent(descriptionText: cmd.toString(), isStateChange: false) | |
} | |
/********************************************************************** | |
* Capability-related Commands: | |
**********************************************************************/ | |
/** | |
* on() - Turns the switch on. | |
* | |
* Required for the "Switch" capability. | |
**/ | |
def on() { | |
log.trace "${device.displayName}: on()" | |
secureSequence([ | |
zwave.basicV1.basicSet(value: 0xFF), | |
zwave.switchMultilevelV1.switchMultilevelGet() | |
],8000) // 8s gap. Dimmer should send a report after the basicSet, the switchMultilevelGet is only needed in case the auto-report is missed. | |
} | |
/** | |
* off() - Turns the switch off. | |
* | |
* Required for the "Switch" capability. | |
**/ | |
def off() { | |
log.trace "${device.displayName}: off()" | |
secureSequence([ | |
zwave.basicV1.basicSet(value: 0x00), | |
zwave.switchMultilevelV1.switchMultilevelGet() | |
],8000) // 8s gap. Dimmer should send a report after the basicSet, the switchMultilevelGet is only needed in case the auto-report is missed. | |
} | |
/** | |
* setLevel() | |
* | |
* Required for the "Switch Level" capability. | |
**/ | |
def setLevel(level) { | |
log.trace "${device.displayName}: setLevel(${level})" | |
if (level > 99) level = 99 | |
secureSequence([ | |
zwave.basicV1.basicSet(value: level), | |
zwave.switchMultilevelV1.switchMultilevelGet() | |
],8000) // 8s gap. Dimmer should send a report after the basicSet, the switchMultilevelGet is only needed in case the auto-report is missed. | |
} | |
/** | |
* poll() - Polls the device. | |
* | |
* Required for the "Polling" capability | |
**/ | |
def poll() { | |
log.trace("${device.displayName}: poll()") | |
secureSequence([ | |
zwave.switchMultilevelV1.switchMultilevelGet(), | |
zwave.meterV3.meterGet(scale: 0), | |
zwave.meterV3.meterGet(scale: 2) | |
]) | |
} | |
/** | |
* refresh() - Refreshes values from the device. Same as poll()? | |
* | |
* Required for the "Refresh" capability. | |
**/ | |
def refresh() { | |
log.trace("${device.displayName}: refresh()") | |
secureSequence([ | |
zwave.switchMultilevelV1.switchMultilevelGet(), | |
zwave.meterV3.meterGet(scale: 0), | |
zwave.meterV3.meterGet(scale: 2) | |
]) | |
} | |
/** | |
* reset() - Reset the Accumulated Energy figure held in the device. | |
* | |
**/ | |
def reset() { | |
log.trace("${device.displayName}: reset()") | |
state.lastReset = new Date().format("YYYY/MM/dd \n HH:mm:ss", location.timeZone) | |
sendEvent(name: "lastReset", value: state.lastReset, unit: "",descriptionText: "Accumulated Energy Reset") | |
state.energy = 0.00 | |
return secureSequence([ | |
zwave.meterV3.meterReset(), | |
zwave.meterV3.meterGet(scale: 0) | |
],500) | |
} | |
/** | |
* configure() - Not sure when this is run? | |
* | |
**/ | |
def configure() { | |
// Wait until after the secure exchange for this | |
log.debug "configure()" | |
} | |
/** | |
* installed() - Runs when the device is first installed. | |
**/ | |
def installed() { | |
log.debug "${device.displayName}: installed()" | |
state.installedAt = now() | |
state.energy = 0 | |
state.lastReset = new Date().format("YYYY/MM/dd \n HH:mm:ss", location.timeZone) | |
} | |
/** | |
* updated() - Runs when you hit "Done" from "Edit Device". | |
* | |
* Weirdly, it seems to be called twice after hitting "Done"! | |
* | |
* Note, the updated() method is not a 'command', so it doesn't send commands by default. | |
* To execute commands from updated() you have to specifically return a HubAction object. | |
* The response() helper wraps commands up in a HubAction so they can be sent from parse() or updated(). | |
* See: https://community.smartthings.com/t/remotec-z-thermostat-configuration-with-z-wave-commands/31956/12 | |
**/ | |
def updated() { | |
log.debug "${device.displayName}: Updated()" | |
// Update internal state: | |
state.debug = ("true" == configDebugMode) | |
state.preferencesCache_param19 = param19.toInteger() | |
// Manage Schedules: | |
manageSchedules() | |
// Configure device: | |
response(["delay 2000"] + configureAfterSecure() + refresh()) | |
} | |
/** | |
* manageSchedules() - Unschedule/schedule Nightmode Start and Stop. | |
**/ | |
def manageSchedules() { | |
if (state.debug) log.debug "$device.displayName: manageSchedules()" | |
if (configNightmodeStartTime) { | |
if (state.debug) log.debug "$device.displayName: manageSchedules(): Nightmode scheduled to start at ${configNightmodeStartTime}" | |
schedule(configNightmodeStartTime, "enableNightmode") | |
} else { | |
try { | |
unschedule("enableNightmode") | |
} | |
catch(e) { | |
// Unschedule failed | |
} | |
} | |
if (configNightmodeStopTime) { | |
if (state.debug) log.debug "$device.displayName: manageSchedules(): Nightmode scheduled to stop at ${configNightmodeStopTime}" | |
schedule(configNightmodeStopTime, "disableNightmode") | |
} else { | |
try { | |
unschedule("disableNightmode") | |
} | |
catch(e) { | |
// Unschedule failed | |
} | |
} | |
} | |
/********************************************************************** | |
* Custom Commands: | |
**********************************************************************/ | |
/** | |
* enableNightmode(level) | |
* | |
* Force switch-on illuminance level. | |
**/ | |
def enableNightmode(level=-1) { | |
log.info "${device.displayName}: enableNightmode(${level})" | |
def cmds = [] | |
// Clean level value: | |
if (level == -1) level = configNightmodeLevel | |
if (level > 99) level = 99 | |
if (level < 1) level = 1 | |
// If nightmode is not already active, save current level and current value of param19, so they can be restored when nightmode is stopped: | |
if (!state.nightmodeActive) { | |
state.nightmodePriorLevel = device.latestValue("level") | |
log.info "${device.displayName}: enableNightmode(): Saved previous level: ${state.nightmodePriorLevel}" | |
if (!state.preferencesCache_param19) state.preferencesCache_param19 = 0 | |
state.nightmodePriorParam19 = state.preferencesCache_param19.toInteger() | |
log.info "${device.displayName}: enableNightmode(): Saved previous param19: ${state.nightmodePriorParam19}" | |
} | |
// If the dimmer is already on, and configNightmodeForce is enabled, then adjust the level immediately: | |
if (("on" == device.latestValue("switch")) & ("true" == configNightmodeForce)) cmds << secure(zwave.basicV1.basicSet(value: level)) | |
state.nightmodeActive = true | |
sendEvent(name: "nightmode", value: "Enabled", descriptionText: "Nightmode Enabled", isStateChange: true) | |
// Update parameter #19 for force next switch-on level: | |
cmds << secure(zwave.configurationV1.configurationSet(parameterNumber: 19, size: 1, scaledConfigurationValue: level)) | |
cmds | |
} | |
/** | |
* disableNightmode() | |
* | |
* Stop nightmode and restore previous values. | |
**/ | |
def disableNightmode() { | |
log.info "${device.displayName}: disableNightmode()" | |
def cmds = [] | |
// If nightmode is active, restore param19: | |
if (state.nightmodeActive) { | |
if (state.debug) log.debug "${device.displayName}: disableNightmode(): Restoring previous value of param19 to: ${state.nightmodePriorParam19}" | |
cmds << secure(zwave.configurationV1.configurationSet(parameterNumber: 19, size: 1, scaledConfigurationValue: state.nightmodePriorParam19.toInteger())) | |
state.preferencesCache_param19 = state.nightmodePriorParam19 | |
if (("on" == device.latestValue("switch")) & ("true" == configNightmodeForce)) { | |
// Dimmer is already on and configNightmodeForce is enabled, so adjust the level immediately: | |
if (state.debug) log.debug "${device.displayName}: disableNightmode(): Restoring level to: ${state.nightmodePriorLevel}" | |
cmds << secure(zwave.basicV1.basicSet(value: state.nightmodePriorLevel.toInteger())) | |
} else if (0 == state.preferencesCache_param19) { | |
// Dimmer is off (or configNightmodeForce is not enabled), so need to set a flag to restore the level after it's switched on again, but only if param19 is zero. | |
if (state.debug) log.debug "${device.displayName}: disableNightmode(): Setting flag to restore level at next switch-on: ${state.nightmodePriorLevel}" | |
state.nightmodePendingLevel = state.nightmodePriorLevel | |
} | |
} | |
state.nightmodeActive = false | |
sendEvent(name: "nightmode", value: "Disabled", descriptionText: "Nightmode Disabled", isStateChange: true) | |
cmds | |
} | |
/** | |
* checkNightmode() | |
* | |
* Checks nightmodePendingLevel to see if there's a pending level which should be restored. | |
**/ | |
def checkNightmode() { | |
if (state.debug) log.debug "$device.displayName: checkNightmode()" | |
def cmds = [] | |
if (state.nightmodePendingLevel) { | |
if (state.debug) log.debug "$device.displayName: checkNightmode(): Applying Pending Level: ${state.nightmodePendingLevel}" | |
cmds = setLevel(state.nightmodePendingLevel) | |
state.nightmodePendingLevel = false | |
} | |
cmds | |
} | |
/** | |
* toggleNightmode() | |
**/ | |
def toggleNightmode() { | |
if (state.debug) log.debug "$device.displayName: toggleNightmode()" | |
if (state.nightmodeActive) { | |
disableNightmode() | |
} | |
else { | |
enableNightmode(configNightmodeLevel) | |
} | |
} | |
/** | |
* changeSingleParamAfterSecure() - Change a single device parameter. | |
**/ | |
def changeSingleParamAfterSecure(paramNum, paramSize, paramValue) { | |
log.debug "changeSingleParamAfterSecure(paramNum: $paramNum, paramSize: $paramSize, paramValue: $paramValue)" | |
def cmds = secureSequence([ | |
zwave.configurationV1.configurationSet(parameterNumber: paramNum, size: paramSize, scaledConfigurationValue: paramValue) | |
]) | |
cmds | |
} | |
/** | |
* configureAfterSecure() - Set device parameters. | |
**/ | |
def configureAfterSecure() { | |
log.debug "configureAfterSecure()" | |
def cmds = secureSequence([ | |
zwave.configurationV1.configurationSet(parameterNumber: 1, size: 1, scaledConfigurationValue: param1.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 2, size: 1, scaledConfigurationValue: param2.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 3, size: 1, scaledConfigurationValue: param3.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 4, size: 2, scaledConfigurationValue: param4.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 5, size: 1, scaledConfigurationValue: param5.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 6, size: 2, scaledConfigurationValue: param6.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 7, size: 1, scaledConfigurationValue: param7.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 8, size: 2, scaledConfigurationValue: param8.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 9, size: 1, scaledConfigurationValue: param9.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 10, size: 2, scaledConfigurationValue: param10.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 11, size: 2, scaledConfigurationValue: param11.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 13, size: 1, scaledConfigurationValue: param13.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 15, size: 1, scaledConfigurationValue: param15.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 16, size: 2, scaledConfigurationValue: param16.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 19, size: 1, scaledConfigurationValue: param19.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 20, size: 1, scaledConfigurationValue: param20.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 21, size: 1, scaledConfigurationValue: param21.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 22, size: 1, scaledConfigurationValue: param22.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 23, size: 1, scaledConfigurationValue: param23.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 24, size: 1, scaledConfigurationValue: param24.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 25, size: 1, scaledConfigurationValue: param25.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 26, size: 1, scaledConfigurationValue: param26.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 27, size: 1, scaledConfigurationValue: param27.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 28, size: 1, scaledConfigurationValue: param28.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 29, size: 1, scaledConfigurationValue: param29.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 30, size: 1, scaledConfigurationValue: param30.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 32, size: 1, scaledConfigurationValue: param32.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 34, size: 1, scaledConfigurationValue: param34.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 35, size: 1, scaledConfigurationValue: param35.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 37, size: 1, scaledConfigurationValue: param37.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 39, size: 2, scaledConfigurationValue: param39.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 40, size: 1, scaledConfigurationValue: param40.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 41, size: 1, scaledConfigurationValue: param41.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 42, size: 1, scaledConfigurationValue: param42.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 43, size: 1, scaledConfigurationValue: param43.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 44, size: 2, scaledConfigurationValue: param44.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 45, size: 1, scaledConfigurationValue: param45.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 46, size: 1, scaledConfigurationValue: param46.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 47, size: 1, scaledConfigurationValue: param47.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 48, size: 1, scaledConfigurationValue: param48.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 49, size: 1, scaledConfigurationValue: param49.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 50, size: 1, scaledConfigurationValue: param50.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 52, size: 2, scaledConfigurationValue: param52.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 53, size: 2, scaledConfigurationValue: param53.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 54, size: 1, scaledConfigurationValue: param54.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 58, size: 1, scaledConfigurationValue: param58.toInteger()), | |
zwave.configurationV1.configurationSet(parameterNumber: 59, size: 2, scaledConfigurationValue: param59.toInteger()) | |
]) | |
// Register for Group 1 | |
if(paramAssociationGroup1) { | |
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:1, nodeId: [zwaveHubNodeId])) | |
} | |
else { | |
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:1, nodeId: [zwaveHubNodeId])) | |
} | |
// Register for Group 2 | |
if(paramAssociationGroup2) { | |
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:2, nodeId: [zwaveHubNodeId])) | |
} | |
else { | |
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:2, nodeId: [zwaveHubNodeId])) | |
} | |
// Register for Group 3 | |
if(paramAssociationGroup3) { | |
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:3, nodeId: [zwaveHubNodeId])) | |
} | |
else { | |
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:3, nodeId: [zwaveHubNodeId])) | |
} | |
// Register for Group 4 | |
if(paramAssociationGroup4) { | |
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:4, nodeId: [zwaveHubNodeId])) | |
} | |
else { | |
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:4, nodeId: [zwaveHubNodeId])) | |
//cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:4, nodeId: [10])) | |
} | |
// Register for Group 5 | |
if(paramAssociationGroup5) { | |
//cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:5, nodeId: [zwaveHubNodeId])) | |
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:5, nodeId: [10])) | |
} | |
else { | |
//cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:5, nodeId: [zwaveHubNodeId])) | |
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:5, nodeId: [10])) | |
} | |
cmds | |
} | |
/** | |
* secure() - Encapsulate zwave commands. | |
**/ | |
private secure(physicalgraph.zwave.Command cmd) { | |
log.trace(cmd) | |
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format() | |
} | |
/** | |
* secureSequence() - Secure and send an array of commands. | |
**/ | |
private secureSequence(commands, delay=200) { | |
log.debug "$commands" | |
delayBetween(commands.collect{ secure(it) }, delay) | |
} | |
/** | |
* getConfigReport() - Get current device parameters and output to debug log. | |
* | |
* The device settings in the UI cannot be updated due to platform restrictions. | |
*/ | |
def getConfigReport() { | |
log.debug "Getting Device Configuration" | |
def cmds = [] | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 1) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 2) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 3) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 4) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 5) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 6) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 7) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 8) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 9) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 10) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 11) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 13) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 19) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 30) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 31) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 32) | |
cmds << zwave.configurationV1.configurationGet(parameterNumber: 34) | |
secureSequence(cmds, 200) | |
} | |
/** | |
* test() - Temp testing method. | |
**/ | |
def test() { | |
if (state.debug) log.debug "$device.displayName: Test()" | |
//manageSchedules() | |
} |