Created
July 18, 2014 16:42
-
-
Save stowler/a3b20e5703d8e7b359f7 to your computer and use it in GitHub Desktop.
Keith emailed export of Philips exam card for Aerobic Fitness language task
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Version:1.0 StartHTML:0000000256 EndHTML:0000041465 StartFragment:0000019692 EndFragment:0000041425 SourceURL:file:///P:\BIRC%20imaging\RESEARCH\OTHER%20STUDIES\AerobicFitnessStudy\Zvinkawordgen\fMRI\ScannerParameters\Cog_fMRI_scanner_exam_card.docx | |
Nucleus = "H1"; | |
Coil selection = "SENSE-Head-8"; | |
element selection = "SENSE"; | |
connection = "d"; | |
Dual coil = "no"; | |
CLEAR = "yes"; | |
body tuned = "no"; | |
FOV FH (mm) = 240; | |
AP (mm) = 240; | |
RL (mm) = 146.25; | |
Voxel size FH (mm) = 3.75; | |
AP (mm) = 3.75; | |
Slice thickness (mm) = 3.75; | |
Recon voxel size (mm) = 3.75; | |
Fold-over suppression = "no"; | |
Reconstruction matrix = 64; | |
SENSE = "yes"; | |
P reduction (AP) = 1.5; | |
P os factor = 1; | |
k-t BLAST = "no"; | |
Stacks = 1; | |
type = "parallel"; | |
slices = 39; | |
slice gap = "user defined"; | |
gap (mm) = 0; | |
slice orientation = "sagittal"; | |
fold-over direction = "AP"; | |
fat shift direction = "P"; | |
Stack Offc. AP (P=+mm) = 1.25417912; | |
RL (L=+mm) = 0.418060124; | |
FH (H=+mm) = 26.7558517; | |
Ang. AP (deg) = 0; | |
RL (deg) = 0; | |
FH (deg) = 0; | |
Minimum number of packages = 1; | |
Slice scan order = "ascend"; | |
Large table movement = "no"; | |
PlanAlign = "no"; | |
REST slabs = 0; | |
Interactive positioning = "no"; | |
Patient position = "head first"; | |
orientation = "supine"; | |
Scan type = "Imaging"; | |
Scan mode = "MS"; | |
technique = "FFE"; | |
Contrast enhancement = "no"; | |
Acquisition mode = "cartesian"; | |
Fast Imaging mode = "EPI"; | |
shot mode = "single-shot"; | |
Echoes = 1; | |
partial echo = "no"; | |
shifted echo = "no"; | |
TE = "user defined"; | |
(ms) = 30; | |
Flip angle (deg) = 70; | |
TR = "user defined"; | |
(ms) = 2000; | |
Halfscan = "no"; | |
Water-fat shift = "minimum"; | |
Shim = "auto"; | |
Fat suppression = "SPIR"; | |
strength = "strong"; | |
frequency offset = "default"; | |
Water suppression = "no"; | |
MTC = "no"; | |
Research prepulse = "no"; | |
Diffusion mode = "no"; | |
SAR mode = "high"; | |
B1 mode = "default"; | |
PNS mode = "high"; | |
Gradient mode = "maximum"; | |
SofTone mode = "no"; | |
Cardiac synchronization = "no"; | |
Respiratory compensation = "no"; | |
Navigator respiratory comp = "no"; | |
Flow compensation = "no"; | |
Temporal slice spacing = "equidistant"; | |
fMRI echo stabilisation = "no"; | |
NSA = 1; | |
Angio / Contrast enh. = "no"; | |
Quantitative flow = "no"; | |
Manual start = "yes"; | |
Dynamic study = "individual"; | |
dyn scans = 180; | |
recon multiplier = 1; | |
dyn scan times = "shortest"; | |
dummy scans = 2; | |
immediate subtraction = "no"; | |
fast next scan = "no"; | |
synch. ext. device = "yes"; | |
start at dyn. = 1; | |
interval (dyn) = 1; | |
dyn stabilization = "yes"; | |
prospect. motion corr. = "no"; | |
Keyhole = "no"; | |
Arterial Spin labeling = "no"; | |
Preparation phases = "full"; | |
Manual Offset Freq. = "no"; | |
B0 field map/Dixon = "no"; | |
B1 field map = "no"; | |
MIP/MPR = "no"; | |
Images = " M", (3) " no"; | |
Autoview image = " M"; | |
Calculated images = (4) " no"; | |
Reference tissue = "Grey matter"; | |
EPI 2D phase correction = "no"; | |
Preset window contrast = "soft"; | |
Reconstruction mode = "real time"; | |
reuse memory = "no"; | |
Save raw data = "no"; | |
Hardcopy protocol = "no"; | |
Ringing filtering = "default"; | |
Geometry correction = "default"; | |
IF_info_seperator = 0; | |
Total scan duration = "06:08.0"; | |
Rel. signal level (%) = 100; | |
Act. TR/TE (ms) = "2000 / 30"; | |
Dyn. scan time = "00:02.0"; | |
ACQ matrix M x P = "64 x 63"; | |
ACQ voxel MPS (mm) = "3.75 / 3.75 / 3.75"; | |
REC voxel MPS (mm) = "3.75 / 3.75 / 3.75"; | |
Scan percentage (%) = 100; | |
Packages = 1; | |
Min. slice gap (mm) = 0; | |
EPI factor = 47; | |
Act. WFS (pix) / BW (Hz) = "7.646 / 56.8"; | |
BW in EPI freq. dir. (Hz) = "4888.5"; | |
Min. WFS (pix) / Max. BW (Hz) = "7.622 / 57.0"; | |
Min. TR/TE (ms) = "1909 / 9.9"; | |
SAR / head = "< 33 % / 1.0 W/kg"; | |
Whole body / level = "< 0.1 W/kg / normal"; | |
B1 rms [uT] = 1.33725107; | |
PNS / level = "78 % / normal"; | |
Sound Pressure Level (dB) = 32.19944; |