# Victron modbus connection | |
modbus: | |
- name: camper-victron | |
type: tcp | |
host: 1.2.3.4 | |
port: 502 | |
sensors: | |
- name: System DC Load | |
unit_of_measurement: 'W' | |
device_class: power | |
slave: 100 # System | |
address: 860 | |
data_type: int16 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: Battery Runtime Remaining | |
slave: 100 # System | |
address: 846 | |
data_type: uint16 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: BMV Battery Level | |
unit_of_measurement: '%' | |
slave: 226 # BMV-712 | |
address: 266 | |
data_type: uint16 | |
scale: 0.1 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: BMV Battery Health | |
unit_of_measurement: '%' | |
slave: 226 # BMV-712 | |
address: 304 | |
data_type: uint16 | |
scale: 0.1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: BMV Battery Current | |
unit_of_measurement: 'A' | |
device_class: current | |
slave: 226 # BMV-712 | |
address: 261 | |
data_type: int16 | |
scale: 0.1 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: BMV Battery Voltage | |
unit_of_measurement: 'V' | |
device_class: voltage | |
slave: 226 # BMV-712 | |
address: 259 | |
data_type: uint16 | |
scale: 0.01 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: BMV Truck Battery Voltage | |
unit_of_measurement: 'V' | |
device_class: voltage | |
slave: 226 # BMV-712 | |
address: 260 | |
data_type: uint16 | |
scale: 0.01 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: BMV Battery Discharged Energy | |
unit_of_measurement: 'kWh' | |
device_class: energy | |
state_class: total_increasing | |
slave: 226 # BMV-712 | |
address: 301 | |
data_type: uint16 | |
scale: 0.1 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: BMV Battery Charged Energy | |
unit_of_measurement: 'kWh' | |
device_class: energy | |
state_class: total_increasing | |
slave: 226 # BMV-712 | |
address: 302 | |
data_type: uint16 | |
scale: 0.1 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MPPT Battery Temperature | |
unit_of_measurement: 'C' | |
device_class: temperature | |
slave: 224 # MPPT 100/30 | |
address: 773 | |
data_type: int16 | |
scale: 0.1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MPPT Solar Power | |
unit_of_measurement: 'W' | |
device_class: power | |
state_class: measurement | |
slave: 224 # MPPT 100/30 | |
address: 789 | |
data_type: uint16 | |
scale: 0.1 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MPPT Solar Panel Current | |
unit_of_measurement: 'A' | |
device_class: current | |
slave: 224 # MPPT 100/30 | |
address: 777 | |
data_type: int16 | |
scale: 0.1 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MPPT Solar Panel Voltage | |
unit_of_measurement: 'V' | |
device_class: voltage | |
slave: 224 # MPPT 100/30 | |
address: 776 | |
data_type: uint16 | |
scale: 0.01 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MPPT Solar Charger State | |
slave: 224 # MPPT 100/30 | |
address: 775 | |
data_type: uint16 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Input Voltage | |
unit_of_measurement: 'V' | |
device_class: voltage | |
slave: 227 # MultiPlus | |
address: 3 | |
data_type: uint16 | |
scale: 0.1 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Input Current | |
unit_of_measurement: 'A' | |
device_class: current | |
slave: 227 # MultiPlus | |
address: 6 | |
data_type: int16 | |
scale: 0.1 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Input Frequency | |
unit_of_measurement: 'Hz' | |
device_class: frequency | |
slave: 227 # MultiPlus | |
address: 9 | |
data_type: int16 | |
scale: 0.01 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Input Power | |
unit_of_measurement: 'W' | |
device_class: power | |
slave: 227 # MultiPlus | |
address: 12 | |
data_type: int16 | |
scale: 10 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Output Voltage | |
unit_of_measurement: 'V' | |
device_class: voltage | |
slave: 227 # MultiPlus | |
address: 15 | |
data_type: uint16 | |
scale: 0.1 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Output Current | |
unit_of_measurement: 'A' | |
device_class: current | |
slave: 227 # MultiPlus | |
address: 18 | |
data_type: int16 | |
scale: 0.1 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Output Frequency | |
unit_of_measurement: 'Hz' | |
device_class: frequency | |
slave: 227 # MultiPlus | |
address: 21 | |
data_type: int16 | |
scale: 0.01 | |
precision: 1 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Active Input Current Limit | |
unit_of_measurement: 'A' | |
device_class: current | |
slave: 227 # MultiPlus | |
address: 22 | |
data_type: int16 | |
scale: 0.1 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Output Power | |
unit_of_measurement: 'W' | |
device_class: power | |
slave: 227 # MultiPlus | |
address: 23 | |
data_type: int16 | |
scale: 10 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Battery Voltage | |
unit_of_measurement: 'V' | |
device_class: voltage | |
slave: 227 # MultiPlus | |
address: 26 | |
data_type: uint16 | |
scale: 0.01 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Battery Current | |
unit_of_measurement: 'A' | |
device_class: current | |
slave: 227 # MultiPlus | |
address: 27 | |
data_type: int16 | |
scale: 0.1 | |
precision: 2 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Active Input | |
slave: 227 # MultiPlus | |
address: 29 | |
data_type: uint16 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus State | |
slave: 227 # MultiPlus | |
address: 31 | |
data_type: uint16 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Error | |
slave: 227 # MultiPlus | |
address: 32 | |
data_type: uint16 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Switch Position | |
slave: 227 # MultiPlus | |
address: 33 | |
data_type: uint16 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Low Battery Alarm | |
slave: 227 # MultiPlus | |
address: 35 | |
data_type: uint16 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: MultiPlus Overload Alarm | |
slave: 227 # MultiPlus | |
address: 36 | |
data_type: uint16 | |
precision: 0 | |
scan_interval: 10 | |
lazy_error_count: 3 | |
- name: Victron Interior Temperature Raw | |
unit_of_measurement: °C | |
device_class: temperature | |
slave: 28 # Interior Ruuvi | |
address: 3304 | |
data_type: int16 | |
scale: 0.01 | |
precision: 1 | |
scan_interval: 60 | |
lazy_error_count: 3 | |
# Ruuvi humidity/temperature sensors are not being exposed via modbus properly at the current time | |
# - name: Victron Interior Humidity | |
# unit_of_measurement: '%' | |
# device_class: humidity | |
# slave: 28 # Interior Ruuvi | |
# address: 3306 | |
# data_type: uint16 | |
# scale: 0.1 | |
# precision: 1 | |
# scan_interval: 60 | |
# lazy_error_count: 3 | |
# - name: Victron Interior Pressure | |
# unit_of_measurement: hPa | |
# device_class: pressure | |
# slave: 28 # Interior Ruuvi | |
# address: 3308 | |
# data_type: uint16 | |
# precision: 1 | |
# scan_interval: 60 | |
# lazy_error_count: 3 | |
- name: Victron Outside Temperature Raw | |
unit_of_measurement: °C | |
device_class: temperature | |
slave: 29 # Outside Ruuvi | |
address: 3304 | |
data_type: int16 | |
scale: 0.01 | |
precision: 1 | |
scan_interval: 60 | |
lazy_error_count: 3 | |
- name: Victron Plumbing Temperature Raw | |
unit_of_measurement: °C | |
device_class: temperature | |
slave: 30 # Plumbing Ruuvi | |
address: 3304 | |
data_type: int16 | |
scale: 0.01 | |
precision: 1 | |
scan_interval: 60 | |
lazy_error_count: 3 | |
- name: Victron Freezer Temperature Raw | |
unit_of_measurement: °C | |
device_class: temperature | |
slave: 31 # Freezer Ruuvi | |
address: 3304 | |
data_type: int16 | |
scale: 0.01 | |
precision: 1 | |
scan_interval: 60 | |
lazy_error_count: 3 | |
- name: Victron Fridge Temperature Raw | |
unit_of_measurement: °C | |
device_class: temperature | |
slave: 32 # Fridge Ruuvi | |
address: 3304 | |
data_type: int16 | |
scale: 0.01 | |
precision: 1 | |
scan_interval: 60 | |
lazy_error_count: 3 | |
template: | |
- sensor: | |
- name: Battery Discharged Energy | |
unit_of_measurement: 'kWh' | |
state_class: total_increasing | |
device_class: energy | |
state: "{{ states('sensor.bmv_battery_discharged_energy') }}" | |
- name: Battery Charged Energy | |
unit_of_measurement: 'kWh' | |
state_class: total_increasing | |
device_class: energy | |
state: "{{ states('sensor.bmv_battery_charged_energy') }}" | |
- name: Multiplus Active Input Text | |
state: > | |
{% if is_state('sensor.multiplus_active_input', '0') %} | |
AC Input 1 | |
{% elif is_state('sensor.multiplus_active_input', '1') %} | |
AC Input 2 | |
{% elif is_state('sensor.multiplus_active_input', '240') %} | |
Disconnected | |
{% else %} | |
Unknown | |
{% endif %} | |
icon: > | |
{% if is_state('sensor.multiplus_active_input', '0') %} | |
mdi:toggle-switch | |
{% elif is_state('sensor.multiplus_active_input', '1') %} | |
mdi:toggle-switch | |
{% elif is_state('sensor.multiplus_active_input', '240') %} | |
mdi:toggle-switch-off-outline | |
{% else %} | |
mdi:help | |
{% endif %} | |
- name: MPPT Solar Charger State Text | |
state: > | |
{% if is_state('sensor.mppt_solar_charger_state', '0') %} | |
Off | |
{% elif is_state('sensor.mppt_solar_charger_state', '2') %} | |
Fault | |
{% elif is_state('sensor.mppt_solar_charger_state', '3') %} | |
Bulk | |
{% elif is_state('sensor.mppt_solar_charger_state', '4') %} | |
Absorption | |
{% elif is_state('sensor.mppt_solar_charger_state', '5') %} | |
Float | |
{% elif is_state('sensor.mppt_solar_charger_state', '6') %} | |
Storage | |
{% elif is_state('sensor.mppt_solar_charger_state', '7') %} | |
Equalize | |
{% elif is_state('sensor.mppt_solar_charger_state', '11') %} | |
Other | |
{% elif is_state('sensor.mppt_solar_charger_state', '252') %} | |
External Control | |
{% else %} | |
Unknown | |
{% endif %} | |
icon: > | |
{% if is_state('sensor.mppt_solar_charger_state', '0') %} | |
mdi:toggle-switch-off-outline | |
{% elif is_state('sensor.mppt_solar_charger_state', '2') %} | |
mdi:exclamation | |
{% elif is_state('sensor.mppt_solar_charger_state', '3') %} | |
mdi:battery-charging-low | |
{% elif is_state('sensor.mppt_solar_charger_state', '4') %} | |
mdi:battery-charging-medium | |
{% elif is_state('sensor.mppt_solar_charger_state', '5') %} | |
mdi:battery-charging-high | |
{% elif is_state('sensor.mppt_solar_charger_state', '6') %} | |
mdi:battery-high | |
{% elif is_state('sensor.mppt_solar_charger_state', '7') %} | |
mdi:battery-check-outline | |
{% elif is_state('sensor.mppt_solar_charger_state', '11') %} | |
mdi:asterisk | |
{% elif is_state('sensor.mppt_solar_charger_state', '252') %} | |
mdi:open-in-new | |
{% else %} | |
mdi:help | |
{% endif %} | |
- name: Multiplus Switch Position Text | |
state: > | |
{% if is_state('sensor.multiplus_switch_position', '1') %} | |
Charger Only | |
{% elif is_state('sensor.multiplus_switch_position', '2') %} | |
Inverter Only | |
{% elif is_state('sensor.multiplus_switch_position', '3') %} | |
Inverter/Charger | |
{% elif is_state('sensor.multiplus_switch_position', '4') %} | |
Off | |
{% else %} | |
Unknown | |
{% endif %} | |
icon: > | |
{% if is_state('sensor.multiplus_switch_position', '1') %} | |
mdi:transmission-tower-import | |
{% elif is_state('sensor.multiplus_switch_position', '2') %} | |
mdi:transmission-tower-export | |
{% elif is_state('sensor.multiplus_switch_position', '3') %} | |
mdi:transmission-tower | |
{% elif is_state('sensor.multiplus_switch_position', '4') %} | |
mdi:toggle-switch-off-outline | |
{% else %} | |
mdi:help | |
{% endif %} | |
- name: Multiplus State Text | |
state: > | |
{% if is_state('sensor.multiplus_state', '0') %} | |
Off | |
{% elif is_state('sensor.multiplus_state', '1') %} | |
Low Power | |
{% elif is_state('sensor.multiplus_state', '2') %} | |
Fault | |
{% elif is_state('sensor.multiplus_state', '3') %} | |
Bulk | |
{% elif is_state('sensor.multiplus_state', '4') %} | |
Absorption | |
{% elif is_state('sensor.multiplus_state', '5') %} | |
Float | |
{% elif is_state('sensor.multiplus_state', '6') %} | |
Storage | |
{% elif is_state('sensor.multiplus_state', '7') %} | |
Equalize | |
{% elif is_state('sensor.multiplus_state', '8') %} | |
Passthrough | |
{% elif is_state('sensor.multiplus_state', '9') %} | |
Inverting | |
{% elif is_state('sensor.multiplus_state', '10') %} | |
Power Assist | |
{% elif is_state('sensor.multiplus_state', '11') %} | |
Power Supply | |
{% elif is_state('sensor.multiplus_state', '252') %} | |
Bulk Protection | |
{% else %} | |
Unknown | |
{% endif %} | |
icon: > | |
{% if is_state('sensor.multiplus_state', '0') %} | |
mdi:toggle-switch-off-outline | |
{% elif is_state('sensor.multiplus_state', '1') %} | |
mdi:battery-arrow-down | |
{% elif is_state('sensor.multiplus_state', '2') %} | |
mdi:exclamation | |
{% elif is_state('sensor.multiplus_state', '3') %} | |
mdi:battery-charging-low | |
{% elif is_state('sensor.multiplus_state', '4') %} | |
mdi:battery-charging-medium | |
{% elif is_state('sensor.multiplus_state', '5') %} | |
mdi:battery-charging-high | |
{% elif is_state('sensor.multiplus_state', '6') %} | |
mdi:battery-high | |
{% elif is_state('sensor.multiplus_state', '7') %} | |
mdi:battery-check-outline | |
{% elif is_state('sensor.multiplus_state', '8') %} | |
mdi:electric-switch-closed | |
{% elif is_state('sensor.multiplus_state', '9') %} | |
mdi:transmission-tower-export | |
{% elif is_state('sensor.multiplus_state', '10') %} | |
mdi:transmission-tower-import | |
{% elif is_state('sensor.multiplus_state', '11') %} | |
mdi:home-battery | |
{% elif is_state('sensor.multiplus_state', '252') %} | |
mdi:battery-alert | |
{% else %} | |
mdi:help | |
{% endif %} | |
- name: Multiplus Overload Alarm Text | |
state: > | |
{% if is_state('sensor.multiplus_overload_alarm', '0') %} | |
Ok | |
{% elif is_state('sensor.multiplus_overload_alarm', '1') %} | |
Warning | |
{% elif is_state('sensor.multiplus_overload_alarm', '2') %} | |
Alarm | |
{% else %} | |
Unknown | |
{% endif %} | |
icon: > | |
{% if is_state('sensor.multiplus_overload_alarm', '0') %} | |
mdi:checkbox-marked-circle | |
{% elif is_state('sensor.multiplus_overload_alarm', '1') %} | |
mdi:alert | |
{% elif is_state('sensor.multiplus_overload_alarm', '2') %} | |
mdi:alert-octagon | |
{% else %} | |
mdi:help | |
{% endif %} | |
- name: Multiplus Low Battery Alarm Text | |
state: > | |
{% if is_state('sensor.multiplus_low_battery_alarm', '0') %} | |
Ok | |
{% elif is_state('sensor.multiplus_low_battery_alarm', '1') %} | |
Warning | |
{% elif is_state('sensor.multiplus_low_battery_alarm', '2') %} | |
Alarm | |
{% else %} | |
Unknown | |
{% endif %} | |
icon: > | |
{% if is_state('sensor.multiplus_low_battery_alarm', '0') %} | |
mdi:checkbox-marked-circle | |
{% elif is_state('sensor.multiplus_low_battery_alarm', '1') %} | |
mdi:alert | |
{% elif is_state('sensor.multiplus_low_battery_alarm', '2') %} | |
mdi:alert-octagon | |
{% else %} | |
mdi:help | |
{% endif %} | |
- name: Battery Runtime Remaining (formatted) | |
state: > | |
{% set time = states.sensor.battery_runtime_remaining.state | int %} | |
{% set minutes = (((time / 36) % 1) * 60) | int %} | |
{% set hours = ((time % 864) / 36) | int %} | |
{% set days = (time / 864) | int %} | |
{%- if time == 0 -%} | |
Charging | |
{%- else -%} | |
{%- if days > 0 -%} | |
{{ days }} Days {{ hours }} Hours {{ minutes }} Minutes | |
{%- else -%} | |
{{ hours }} Hours {{ minutes }} Minutes | |
{%- endif -%} | |
{%- endif -%} | |
- name: Battery Runtime Remaining (hours) | |
state: > | |
{% set time = states.sensor.battery_runtime_remaining.state | int %} | |
{% set hours = (time / 36) | round(1) %} | |
{%- if time == 0 -%} | |
240.0 | |
{%- else -%} | |
{{ hours }} | |
{%- endif -%} | |
unit_of_measurement: h | |
- name: Sun Elevation | |
state: > | |
{%- if state_attr("sun.sun", "elevation") >= 0 %} | |
{{ state_attr("sun.sun", "elevation") }} | |
{%- else %} | |
0.0 | |
{%- endif %} | |
unit_of_measurement: '°' | |
sensor: | |
# Integrations to get kWh measurements for shore power and solar power | |
- platform: integration | |
source: sensor.multiplus_input_power | |
name: MultiPlus Input Power Consumed | |
unit_prefix: k | |
round: 2 | |
method: left | |
- platform: integration | |
source: sensor.mppt_solar_power | |
name: MPPT Solar Power Yield | |
unit_prefix: k | |
round: 2 | |
method: left | |
# Attempt to filter out big swings for Ruuvi sensors that seem to happen on startup | |
- platform: filter | |
name: Victron Interior Temperature | |
entity_id: sensor.victron_interior_temperature_raw | |
unique_id: victron-interior-temperature | |
filters: | |
- filter: outlier | |
window_size: 4 | |
radius: 5.0 | |
- platform: filter | |
name: Victron Outside Temperature | |
entity_id: sensor.victron_outside_temperature_raw | |
unique_id: victron-outside-temperature | |
filters: | |
- filter: outlier | |
window_size: 4 | |
radius: 5.0 | |
- platform: filter | |
name: Victron Plumbing Temperature | |
entity_id: sensor.victron_plumbing_temperature_raw | |
unique_id: victron-plumbing-temperature | |
filters: | |
- filter: outlier | |
window_size: 4 | |
radius: 5.0 | |
- platform: filter | |
name: Victron Freezer Temperature | |
entity_id: sensor.victron_freezer_temperature_raw | |
unique_id: victron-freezer-temperature | |
filters: | |
- filter: outlier | |
window_size: 4 | |
radius: 5.0 | |
- platform: filter | |
name: Victron Fridge Temperature | |
entity_id: sensor.victron_fridge_temperature_raw | |
unique_id: victron-fridge-temperature | |
filters: | |
- filter: outlier | |
window_size: 4 | |
radius: 5.0 | |