Created
January 31, 2012 12:31
-
-
Save tobiasmcnulty/1710278 to your computer and use it in GitHub Desktop.
Sample Kannel configuration for talking to RapidSMS server
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
# | |
# CONFIGURATION FOR USING SMS KANNEL WITH RAPIDSMS | |
# | |
# For any modifications to this file, see Kannel User Guide | |
# If that does not help, see Kannel web page (http://www.kannel.org) and | |
# various online help and mailing list archives | |
# | |
# Notes on those who base their configuration on this: | |
# 1) check security issues! (allowed IPs, passwords and ports) | |
# 2) groups cannot have empty rows inside them! | |
# 3) read the user guide | |
# | |
# Kalle Marjola for Kannel project 2001, 2004 | |
include = "/etc/kannel/modems.conf" | |
#--------------------------------------------- | |
# CORE | |
# | |
# There is only one core group and it sets all basic settings | |
# of the bearerbox (and system). You should take extra notes on | |
# configuration variables like 'store-file' (or 'store-dir'), | |
# 'admin-allow-ip' and 'access.log' | |
group = core | |
admin-port = 13000 | |
smsbox-port = 13001 | |
admin-password = CHANGE ME | |
status-password = CHANGE ME | |
admin-deny-ip = "*.*.*.*" | |
admin-allow-ip = "127.0.0.1" | |
box-deny-ip = "*.*.*.*" | |
box-allow-ip = "127.0.0.1" | |
log-file = "/var/log/kannel/bearerbox.log" | |
log-level = 0 | |
#--------------------------------------------- | |
# SMSC CONNECTIONS | |
# | |
# SMSC connections are created in bearerbox and they handle SMSC specific | |
# protocol and message relying. You need these to actually receive and send | |
# messages to handset, but can use GSM modems as virtual SMSCs | |
# This is a fake smsc connection, _only_ used to test the system and services. | |
# It really cannot relay messages to actual handsets! | |
#group = smsc | |
#smsc = fake | |
#smsc-id = FAKE | |
#port = 20000 | |
#connect-allow-ip = 127.0.0.1 | |
group = smsc | |
smsc = at | |
smsc-id = usb0-modem | |
my-number = 1234 | |
modemtype = auto | |
device = /dev/ttyUSB0 | |
#--------------------------------------------- | |
# SMSBOX SETUP | |
# | |
# Smsbox(es) do higher-level SMS handling after they have been received from | |
# SMS centers by bearerbox, or before they are given to bearerbox for delivery | |
group = smsbox | |
bearerbox-host = 127.0.0.1 | |
sendsms-port = 13013 | |
sendsms-chars = "0123456789 +-" | |
log-file = "/var/log/kannel/smsbox.log" | |
log-level = 0 | |
access-log = "/var/log/kannel/smsbox-access.log" | |
reply-couldnotfetch = "Your message could not be processed at this time. Please try again later. (err=couldnotfetch)" | |
reply-requestfailed = "Your message could not be processed at this time. Please try again later. (err=requestfailed)" | |
reply-couldnotrepresent = "Your message could not be processed at this time. Please try again later. (err=couldnotrepresent)" | |
http-request-retry = 3 | |
http-queue-delay = 10 | |
# SEND-SMS USERS | |
# | |
# These users are used when Kannel smsbox sendsms interface is used to | |
# send PUSH sms messages, i.e. calling URL like | |
# http://kannel.machine:13013/cgi-bin/sendsms?username=tester&password=foobar... | |
# This is the username and password that RapidSMS uses to deliver SMSes to | |
# Kannel. It must also set the 'smsc' variable in the query string, so that | |
# Kannel knows which SMSC to use to route the message. | |
group = sendsms-user | |
username = rapidsms | |
password = CHANGE ME | |
user-deny-ip = "*.*.*.*" | |
user-allow-ip = "127.0.0.1;ip.of.rapidsms.server;" | |
#--------------------------------------------- | |
# SERVICES | |
# | |
# These are 'responses' to sms PULL messages, i.e. messages arriving from | |
# handsets. The response is based on message content. Only one sms-service is | |
# applied, using the first one to match. | |
# The 'ping-kannel' service let's you check to see if Kannel is running, | |
# even if RapidSMS is offline for some reason. | |
group = sms-service | |
keyword = ping-kannel | |
text = "Kannel is online and responding to messages." | |
# There should be always a 'default' service. This service is used when no | |
# other 'sms-service' is applied. These relay incoming messages from Zain | |
# and TNM, respectively, to the appropriate HTTP backend URLs in RapidSMS. | |
# By setting 'accepted-smsc', we are assured that messages are routed to | |
# the appropriate backend in RapidSMS. | |
group = sms-service | |
keyword = default | |
accepted-smsc = usb0-modem | |
# don't send a reply here (it'll come through sendsms): | |
max-messages = 0 | |
get-url = http://my.rapidsms.server.com:8080/?id=%p&text=%a&charset=%C&coding=%c |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
# Modems configuration | |
# | |
# Example and default values | |
# | |
# group = modems | |
# id = "my-id" | |
# name = "my-name" | |
# detect-string = "MODEM" | |
# detect-string2 = "" [Default] | |
# init-string = "AT+CNMI=1,2,0,0,0" [Default] | |
# speed = 9600 [Default] | |
# enable-hwhs = "AT+IFC=2,2" [Default] | |
# need-sleep = false [Default] | |
# no-pin = false [Default] | |
# no-smsc = false [Default] | |
# sendline-sleep = 100 [Default, miliseconds] | |
# keepalive-cmd = "AT" [Default] | |
# broken = false [Default] | |
# message-storage = "SM" | |
# enable-mms = false [Default] | |
# If modemtype=auto, try everyone and defaults to this one | |
group = modems | |
id = generic | |
name = "Generic Modem" | |
group = modems | |
id = wavecom | |
name = Wavecom | |
detect-string = "WAVECOM" | |
init-string = "AT+CNMI=1,2,0,0,0" | |
group = modems | |
id = premicell | |
name = Premicell | |
detect-string = "PREMICEL" | |
no-pin = true | |
no-smsc = true | |
group = modems | |
id = siemens_tc35 | |
name = "Siemens TC35" | |
detect-string = "SIEMENS" | |
detect-string2 = "TC35" | |
init-string = "AT+CNMI=3,2,0,1,1" | |
speed = 19200 | |
enable-hwhs = "AT\\Q3" | |
need-sleep = true | |
reset-string = "AT+CFUN=1" | |
keepalive-cmd = "AT+CSQ" | |
group = modems | |
id = siemens_m20 | |
name = "Siemens M20" | |
detect-string = "SIEMENS" | |
detect-string2 = "M20" | |
speed = 19200 | |
enable-hwhs = "AT\\Q3" | |
keepalive-cmd = "AT+CBC;+CSQ" | |
need-sleep = true | |
group = modems | |
id = siemens_sl45 | |
name = "Siemens SL45" | |
detect-string = "SIEMENS" | |
detect-string2 = "SL45" | |
init-string = "AT+CNMI=1,2,2,2,1" | |
keepalive-cmd = "AT+CBC;+CSQ" | |
speed = 19200 | |
enable-hwhs = "AT\\Q3" | |
need-sleep = true | |
message-storage = "SM" | |
group = modems | |
id = nokiaphone | |
name = "Nokia Phone" | |
detect-string = "Nokia Mobile Phone" | |
need-sleep = true | |
keepalive-cmd = "AT+CBC;+CSQ" | |
enable-mms = true | |
group = modems | |
id = falcom | |
name = "Falcom" | |
detect-string = "Falcom" | |
#no-smsc = true | |
group = modems | |
id = ericsson_r520m | |
name = "Ericsson R520m" | |
detect-string = "R520m" | |
init-string = "AT+CNMI=3,2,0,0" | |
group = modems | |
id = ericsson_t68 | |
name = "Ericsson T68" | |
detect-string = "T68" | |
init-string = "AT+CNMI=3,3" | |
keepalive-cmd = "AT+CBC;+CSQ" | |
broken = true | |
group = modems | |
id = sonyericsson_gr47 | |
name = "Sony Ericsson GR47" | |
detect-string = "GR47" | |
message-storage = "ME" | |
# use this init-string for non sim-buffering | |
init-string = "AT+CNMI=3,2,0,0" | |
# use this init-string for sim-buffering | |
#init-string = "AT+CNMI=3,1,0,0" | |
reset-string = "ATZ" | |
broken = true | |
group = modems | |
id = alcatel | |
name = "Alcatel" | |
detect-string = "Alcatel" | |
init-string = "AT+CNMI=3,2,0,0" | |
group = modems | |
id = sonyericsson_T630-T628 | |
name = "Sony Ericsson T630-T628? | |
init-string = "AT+CNMI=2,3,2,0,0;+CMGF=0? | |
keepalive-cmd = "AT+CBC;+CSQ;+CMGF=0? | |
broken = true | |
group = modems | |
id = sonyericsson_p1i | |
name = "Sony Ericsson P1i" | |
detect-string = "Sony Ericsson P1i" | |
init-string = "ATQ0 V1 E1 S0=0 &C1 &D2 +FCLASS=0" | |
message-storage = "SM" | |
reset-string = "ATZ" | |
broken = true | |
group = modems | |
id = huawei_e1550 | |
name = "Huawei E1550" | |
detect-string = "huawei" | |
init-string = "ATQ0 V1 E1 S0=0 &C1 &D2 +FCLASS=0" | |
#sim-buffering = true | |
message-storage = "SM" | |
need-sleep = true | |
speed = 9600 | |
#speed = 460800 | |
group = modems | |
id = huawei_e620 | |
name = "Huawei E620" | |
detect-string = "huawei" | |
init-string = "AT+CFUN=1" | |
message-storage = "ME" | |
need-sleep = true | |
speed = 460800 | |
no-pin = true | |
reset-string = "AT+CFUN=1" |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
INSTALLED_BACKENDS = { | |
"message_tester": { | |
"ENGINE": "rapidsms.backends.bucket", | |
}, | |
# ... | |
"kannel-cebu" : { | |
"ENGINE": "rapidsms.backends.kannel", | |
"host": "public.ip.of.this_server", | |
"port": 8080, | |
"sendsms_url": "http://remote.ip.of.kannel.server:13013/cgi-bin/sendsms", | |
"sendsms_params": {"smsc": "usb0-modem", | |
"from": "+SIMphonenumber", # not set automatically by SMSC | |
"username": "rapidsms", | |
"password": ""}, # set in localsettings.py | |
"coding": 0, | |
"charset": "ascii", | |
"encode_errors": "ignore", # strip out unknown (unicode) characters | |
} | |
} |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Thanks a lot for sharing this:)