Last active
March 6, 2024 19:35
-
-
Save tronikos/8ff35350e2049e7a52b1bcc4c23e0ebf to your computer and use it in GitHub Desktop.
Home Assistant blueprint for Energy Disaggregation or Non-Intrusive Load Monitoring (NILM)
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
blueprint: | |
name: Energy Disaggregation | |
description: Approximate power usage of an appliance | |
domain: automation | |
input: | |
power_helper: | |
name: Input helper to store the approximate power usage | |
description: in W | |
selector: | |
entity: | |
filter: | |
- domain: input_number | |
timer_helper: | |
name: Timer to reset power to 0W | |
description: Needed in case we miss the current decrease when appliance isn't under load | |
selector: | |
entity: | |
filter: | |
- domain: timer | |
l1_current_derivative: | |
name: L1 current derivative | |
description: (You first need to create a derivative sensor of your L1 current sensor) | |
selector: | |
entity: | |
filter: | |
- domain: sensor | |
integration: derivative | |
l2_current_derivative: | |
name: L2 current derivative | |
description: (You first need to create a derivative sensor of your L2 current sensor) | |
selector: | |
entity: | |
filter: | |
- domain: sensor | |
integration: derivative | |
l1_voltage: | |
name: L1 voltage | |
description: in V | |
selector: | |
entity: | |
filter: | |
- domain: sensor | |
device_class: voltage | |
l2_voltage: | |
name: L2 voltage | |
description: in V | |
selector: | |
entity: | |
filter: | |
- domain: sensor | |
device_class: voltage | |
current_derivative_factor: | |
name: Current derivative factor | |
description: Factor to multiple the derivatives to get A. E.g. if derivatives are in A/s over 10s, multiply by 10 | |
default: 1 | |
selector: | |
number: | |
min: 0.1 | |
max: 100.0 | |
step: 0.1 | |
mode: box | |
l1_lower_bound: | |
name: Lower bound for L1 current derivative | |
description: Assume appliance started if L1 current increased by at least this | |
default: 19 | |
selector: | |
number: | |
min: -100 | |
max: 100.0 | |
step: 0.1 | |
unit_of_measurement: A | |
mode: box | |
l1_upper_bound: | |
name: Upper bound for L1 current derivative | |
description: Assume appliance started if L1 current increased by at most this | |
default: 24 | |
selector: | |
number: | |
min: -100 | |
max: 100.0 | |
step: 0.1 | |
unit_of_measurement: A | |
mode: box | |
l2_lower_bound: | |
name: Lower bound for L2 current derivative | |
description: Assume appliance started if L2 current increased by at least this | |
default: 19 | |
selector: | |
number: | |
min: -100 | |
max: 100.0 | |
step: 0.1 | |
unit_of_measurement: A | |
mode: box | |
l2_upper_bound: | |
name: Upper bound for L2 current derivative | |
description: Assume appliance started if L2 current increased by at most this | |
default: 24 | |
selector: | |
number: | |
min: -100 | |
max: 100.0 | |
step: 0.1 | |
unit_of_measurement: A | |
mode: box | |
delay: | |
name: Delay | |
description: Time duration the current increase/decrease has to stay within the above limits | |
default: | |
seconds: 5 | |
selector: | |
duration: {} | |
trigger_variables: | |
current_derivative_factor: !input current_derivative_factor | |
trigger: | |
- platform: numeric_state | |
entity_id: !input l1_current_derivative | |
value_template: "{{ state.state | float() * current_derivative_factor }}" | |
above: !input l1_lower_bound | |
below: !input l1_upper_bound | |
for: !input delay | |
- platform: numeric_state | |
entity_id: !input l2_current_derivative | |
value_template: "{{ state.state | float() * current_derivative_factor }}" | |
above: !input l2_lower_bound | |
below: !input l2_upper_bound | |
for: !input delay | |
- platform: numeric_state | |
entity_id: !input l1_current_derivative | |
value_template: "{{ state.state | float() * -1 * current_derivative_factor }}" | |
above: !input l1_lower_bound | |
below: !input l1_upper_bound | |
for: !input delay | |
- platform: numeric_state | |
entity_id: !input l2_current_derivative | |
value_template: "{{ state.state | float() * -1 * current_derivative_factor }}" | |
above: !input l2_lower_bound | |
below: !input l2_upper_bound | |
for: !input delay | |
- platform: event | |
event_type: timer.finished | |
event_data: | |
entity_id: !input timer_helper | |
id: timer-finished | |
variables: | |
l1_current_derivative: !input l1_current_derivative | |
l2_current_derivative: !input l2_current_derivative | |
current_derivative_factor: !input current_derivative_factor | |
l1_voltage: !input l1_voltage | |
l2_voltage: !input l2_voltage | |
condition: [] | |
action: | |
- choose: | |
- conditions: | |
- condition: trigger | |
id: | |
- timer-finished | |
sequence: | |
- service: input_number.set_value | |
data: | |
value: 0 | |
target: | |
entity_id: !input power_helper | |
- conditions: | |
- condition: numeric_state | |
entity_id: !input l1_current_derivative | |
value_template: "{{ state.state | float() * current_derivative_factor }}" | |
above: !input l1_lower_bound | |
below: !input l1_upper_bound | |
- condition: numeric_state | |
entity_id: !input l2_current_derivative | |
value_template: "{{ state.state | float() * current_derivative_factor }}" | |
above: !input l2_lower_bound | |
below: !input l2_upper_bound | |
sequence: | |
- service: input_number.set_value | |
data: | |
value: >- | |
{{ states(l1_current_derivative) | float * current_derivative_factor * states(l1_voltage) | float + | |
states(l2_current_derivative) | float * current_derivative_factor * states(l2_voltage) | float }} | |
target: | |
entity_id: !input power_helper | |
- service: timer.start | |
data: {} | |
target: | |
entity_id: !input timer_helper | |
- conditions: | |
- condition: numeric_state | |
entity_id: !input l1_current_derivative | |
value_template: "{{ state.state | float() * current_derivative_factor * -1 }}" | |
above: !input l1_lower_bound | |
below: !input l1_upper_bound | |
- condition: numeric_state | |
entity_id: !input l2_current_derivative | |
value_template: "{{ state.state | float() * current_derivative_factor * -1 }}" | |
above: !input l2_lower_bound | |
below: !input l2_upper_bound | |
sequence: | |
- service: input_number.set_value | |
data: | |
value: 0 | |
target: | |
entity_id: !input power_helper | |
mode: single | |
max_exceeded: silent |