* CO2 Vent | |
* | |
* Copyright 2014 Brian Steere | |
* | |
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except | |
* in compliance with the License. You may obtain a copy of the License at: | |
* | |
* http://www.apache.org/licenses/LICENSE-2.0 | |
* | |
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed | |
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License | |
* for the specific language governing permissions and limitations under the License. | |
* | |
*/ | |
definition( | |
name: "CO2 Vent", | |
namespace: "dianoga", | |
author: "Brian Steere", | |
description: "Turn on a switch when CO2 levels are too high", | |
category: "Health & Wellness", | |
iconUrl: "https://s3.amazonaws.com/smartapp-icons/Convenience/Cat-Convenience.png", | |
iconX2Url: "https://s3.amazonaws.com/smartapp-icons/Convenience/[email protected]" | |
) | |
preferences { | |
section("CO2 Sensor") { | |
input "sensor", "device.netatmoBasestation", title: "Sensor", required: true | |
input "level", "number", title: "CO2 Level", required: true | |
} | |
section("Ventilation Fan") { | |
input "switches", "capability.switch", title: "Switches", required: true, multiple: true | |
} | |
} | |
def installed() { | |
log.debug "Installed with settings: ${settings}" | |
initialize() | |
} | |
def updated() { | |
log.debug "Updated with settings: ${settings}" | |
unsubscribe() | |
initialize() | |
} | |
def initialize() { | |
state.active = false; | |
subscribe(sensor, "carbonDioxide", 'handleLevel') | |
} | |
def handleLevel(evt) { | |
def co2 = sensor.currentValue("carbonDioxide").toInteger() | |
log.debug "CO2 Level: ${co2} / ${settings.level} Active: ${state.active}" | |
if(co2 >= settings.level && !state.active) { | |
log.debug "Turning on" | |
switches.each { it.on(); } | |
state.active = true; | |
} else if(co2 < settings.level && state.active) { | |
log.debug "Turning off" | |
state.active = false; | |
switches.each { it.off(); } | |
} | |
} |