Before you begin, make sure that you have the correct libraries installed. | |
You must install Modbus Library given here: https://code.google.com/archive/p/arduino-modbus-slave/downloads | |
This is just an example taken from that library. I have written no part of this code. All credit goes to the original authors. | |
- xandfury | |
*/ | |
#include <modbus.h> | |
#include <modbusDevice.h> | |
#include <modbusRegBank.h> | |
#include <modbusSlave.h> | |
/* | |
This example code shows a quick and dirty way to get an | |
arduino to talk to a modbus master device with a | |
device ID of 1 at 9600 baud. | |
*/ | |
//Setup the brewtrollers register bank | |
//All of the data accumulated will be stored here | |
modbusDevice regBank; | |
//Create the modbus slave protocol handler | |
modbusSlave slave; | |
void setup() | |
{ | |
//Assign the modbus device ID. | |
regBank.setId(1); | |
/* | |
modbus registers follow the following format | |
00001-09999 Digital Outputs, A master device can read and write to these registers | |
10001-19999 Digital Inputs, A master device can only read the values from these registers | |
30001-39999 Analog Inputs, A master device can only read the values from these registers | |
40001-49999 Analog Outputs, A master device can read and write to these registers | |
Analog values are 16 bit unsigned words stored with a range of 0-32767 | |
Digital values are stored as bytes, a zero value is OFF and any nonzer value is ON | |
It is best to configure registers of like type into contiguous blocks. this | |
allows for more efficient register lookup and and reduces the number of messages | |
required by the master to retrieve the data | |
*/ | |
//Add Digital Output registers 00001-00016 to the register bank | |
regBank.add(1); | |
regBank.add(2); | |
regBank.add(3); | |
regBank.add(4); | |
regBank.add(5); | |
regBank.add(6); | |
regBank.add(7); | |
regBank.add(8); | |
regBank.add(9); | |
regBank.add(10); | |
regBank.add(11); | |
regBank.add(12); | |
regBank.add(13); | |
regBank.add(14); | |
regBank.add(15); | |
regBank.add(16); | |
//Add Digital Input registers 10001-10008 to the register bank | |
regBank.add(10001); | |
regBank.add(10002); | |
regBank.add(10003); | |
regBank.add(10004); | |
regBank.add(10005); | |
regBank.add(10006); | |
regBank.add(10007); | |
regBank.add(10008); | |
//Add Analog Input registers 30001-10010 to the register bank | |
regBank.add(30001); | |
regBank.add(30002); | |
regBank.add(30003); | |
regBank.add(30004); | |
regBank.add(30005); | |
regBank.add(30006); | |
regBank.add(30007); | |
regBank.add(30008); | |
regBank.add(30009); | |
regBank.add(30010); | |
//Add Analog Output registers 40001-40020 to the register bank | |
regBank.add(40001); | |
regBank.add(40002); | |
regBank.add(40003); | |
regBank.add(40004); | |
regBank.add(40005); | |
regBank.add(40006); | |
regBank.add(40007); | |
regBank.add(40008); | |
regBank.add(40009); | |
regBank.add(40010); | |
regBank.add(40011); | |
regBank.add(40012); | |
regBank.add(40013); | |
regBank.add(40014); | |
regBank.add(40015); | |
regBank.add(40016); | |
regBank.add(40017); | |
regBank.add(40018); | |
regBank.add(40019); | |
regBank.add(40020); | |
/* | |
Assign the modbus device object to the protocol handler | |
This is where the protocol handler will look to read and write | |
register data. Currently, a modbus slave protocol handler may | |
only have one device assigned to it. | |
*/ | |
slave._device = ®Bank; | |
// Initialize the serial port for coms at 9600 baud | |
slave.setBaud(9600); | |
} | |
void loop() | |
{ | |
//put some data into the registers | |
regBank.set(1, 1); | |
regBank.set(2, 1); | |
regBank.set(3, 0); | |
regBank.set(4, 1); | |
regBank.set(5, 1); | |
regBank.set(6, 0); | |
regBank.set(7, 1); | |
regBank.set(8, 0); | |
regBank.set(10001, 1); | |
regBank.set(10002, 1); | |
regBank.set(10003, 1); | |
regBank.set(10004, 1); | |
regBank.set(10005, 0); | |
regBank.set(10006, 0); | |
regBank.set(10007, 0); | |
regBank.set(10008, 0); | |
regBank.set(30001,1); | |
regBank.set(30002,2); | |
regBank.set(30003,3); | |
regBank.set(30004,4); | |
regBank.set(30005,5); | |
regBank.set(30006,6); | |
regBank.set(30007,7); | |
regBank.set(30008,8); | |
regBank.set(30009,9); | |
regBank.set(30010,10); | |
regBank.set(40001,1); | |
regBank.set(40002,2); | |
regBank.set(40003,2); | |
regBank.set(40004,4); | |
regBank.set(40005,5); | |
regBank.set(40006,6); | |
regBank.set(40007,7); | |
regBank.set(40008,8); | |
regBank.set(40009,9); | |
regBank.set(40010,10); | |
while(1) | |
{ | |
//put a random number into registers 1, 10001, 30001 and 40001 | |
regBank.set(1, (byte) random(0, 2)); | |
regBank.set(10001, (byte) random(0, 2)); | |
regBank.set(30001, (word) random(0, 32767)); | |
regBank.set(40001, (word) random(0, 32767)); | |
slave.run(); | |
} | |
} |
please share schematic regarding this Code , RS 485 module connection to arduino ?
[email protected] i want send 16 keys push to on data from arduino (as slave) to PLC/ Simply nodebus Software (as MASTER) and want receive error msg to arduino LCD 20x4 , please help
Hi.
When calling 300001 and 400001 the information is swapped around? Anybody sitting with the same problem?
hi , how to Add Digital Input registers more than 8 (100001-19999 )??
just trying with 20 digital input on mega2560, not work !! only 8 digital input can get data, after adress 100008 ,slave only gave data zero.
Dear, I need to know how to do so that with this library I can send modbus float. Thank you best regards
one simple way that works in every case is:
struct modbusLongReg{
uint16_t lsw;
uint16_t msw;
}* mbSplit;
double f = 0.3;
mbSplit = &f;
regBank.set(40001,mbSplit->lsw);
regBank.set(40002,mbSplit->msw);
you can configure word order as you need on the other side.
can you plz share the connections
What's UP Man.
About serial config (slave.setBaud),
How Can I change to 8N2?
And Can I use Serial2 to modbus conection?
Thanks
i am beginner in modbus , how we write analog value on PLC as master