Save JavanXD/a3e8911e69f3a27a81eeeb80414bb6ab to your computer and use it in GitHub Desktop.
# Helpful information: | |
# https://github.com/Excodibur/ioBroker.schwoerer-ventcube/blob/master/src/lib/schwoerer/parameters.ts | |
# https://github.com/fgoettel/wgt/blob/main/wgt/lueftungsanlage.py | |
# https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/diy-do-it-yourself/1822296-modbus-schwörer-heizung?p=1906252#post1906252 | |
################## | |
# MODBUS SENSORS # | |
################## | |
modbus: | |
- name: BIC_VentCube | |
delay: 2 | |
timeout: 3 | |
type: tcp | |
host: !secret wgt_ip | |
port: 502 | |
sensors: | |
- name: VentCube Betriebsart | |
slave: 1 | |
unique_id: ventcube_betriebsart | |
address: 100 | |
# Translated with template sensor | |
# Translated with input_select Automation | |
- name: VentCube Manuelle Luftstufe | |
slave: 1 | |
unique_id: ventcube_manuelle_luftstufe | |
address: 101 | |
# Translated with input_select Automation | |
- name: VentCube Aktuelle Luftstufe | |
slave: 1 | |
unique_id: ventcube_aktuelle_luftstufe | |
address: 102 | |
- name: VentCube Status Stoßlüftung | |
slave: 1 | |
unique_id: ventcube_status_stosslueftung | |
address: 111 | |
# Translated with template sensor | |
- name: VentCube Restlaufzeit Stoßlüftung | |
slave: 1 | |
unique_id: ventcube_restlaufzeit_stosslueftung | |
address: 112 | |
unit_of_measurement: min | |
device_class: duration | |
min_value: 0 | |
max_value: 60 | |
- name: VentCube Status Wärmepumpe | |
slave: 1 | |
unique_id: ventcube_status_waermepumpe | |
address: 114 | |
# Translated with template sensor | |
- name: VentCube Status Nachheizregister | |
slave: 1 | |
unique_id: ventcube_status_nachheizregister | |
address: 116 | |
# Translated with template sensor | |
- name: VentCube Status Gebläse Zuluft | |
slave: 1 | |
unique_id: ventcube_status_geblaese_zuluft | |
address: 117 | |
# Translated with template sensor | |
- name: VentCube Status Gebläse Abluft | |
slave: 1 | |
unique_id: ventcube_status_geblaese_abluft | |
address: 118 | |
# Translated with template sensor | |
- name: VentCube Bypass Zustand | |
slave: 1 | |
unique_id: ventcube_bypass_zustand | |
address: 123 | |
# Translated with template sensor | |
- name: VentCube Zustand Außenklappe | |
slave: 1 | |
unique_id: ventcube_zustand_aussenklappe | |
address: 131 | |
# Translated with template sensor | |
- name: VentCube Status Vorheizregister | |
slave: 1 | |
unique_id: ventcube_status_vorheizregister | |
address: 133 | |
# Translated with template sensor | |
- name: VentCube aktuelle Luftleistung Zuluft | |
slave: 1 | |
unique_id: ventcube_aktuelle_luftleistung_zuluft | |
address: 142 | |
state_class: measurement | |
unit_of_measurement: "%" | |
min_value: 0 | |
max_value: 100 | |
scale: 1 | |
precision: 0 | |
- name: VentCube aktuelle Luftleistung Abluft | |
unique_id: ventcube_aktuelle_luftleistung_abluft | |
slave: 1 | |
address: 143 | |
state_class: measurement | |
unit_of_measurement: "%" | |
min_value: 0 | |
max_value: 100 | |
scale: 1 | |
precision: 0 | |
- name: VentCube aktuelle Drehzahl Zuluft | |
unique_id: ventcube_aktuelle_drehzahl_zuluft | |
slave: 1 | |
address: 144 | |
state_class: measurement | |
unit_of_measurement: "rpm" | |
min_value: 0 | |
max_value: 10000 | |
precision: 0 | |
- name: VentCube aktuelle Drehzahl Abluft | |
unique_id: ventcube_aktuelle_drehzahl_abluft | |
slave: 1 | |
address: 145 | |
state_class: measurement | |
unit_of_measurement: "rpm" | |
min_value: 0 | |
max_value: 10000 | |
precision: 0 | |
- name: VentCube T2 Temperatur nach Vorheizregister | |
slave: 1 | |
unique_id: ventcube_t2_temperatur_nach_vorheizregister | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 201 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T3 Temperatur vor Nacherwärmung | |
slave: 1 | |
unique_id: ventcube_t3_temperatur_vor_nacherwaermung | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 202 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T4 Temperatur nach Nacherwärmung | |
slave: 1 | |
unique_id: ventcube_t4_temperatur_nach_nacherwaermung | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 203 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T5 Temperatur Abluft | |
slave: 1 | |
unique_id: ventcube_t5_temperatur_abluft | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 204 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T6 Temperatur im Wärmetauscher | |
slave: 1 | |
unique_id: ventcube_t6_temperatur_im_waermetauscher | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 205 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube T10 Temperatur Außen | |
slave: 1 | |
unique_id: ventcube_t10_temperatur_aussen | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 209 | |
scale: 0.1 | |
precision: 1 | |
- name: VentCube Heiz- Kühlfunktion | |
slave: 1 | |
unique_id: ventcube_heiz_kuehlfunktion | |
address: 230 | |
# Translated with template sensor | |
# Translated with input_select Automation | |
- name: VentCube Wärmepumpe Heizen | |
slave: 1 | |
unique_id: ventcube_wp_heizen | |
address: 231 | |
- name: VentCube Wärmepumpe Kühlen | |
slave: 1 | |
unique_id: ventcube_wp_kuehlen | |
address: 232 | |
- name: VentCube Druckwächter aktiv | |
slave: 1 | |
unique_id: ventcube_druckwachter_aktiv | |
address: 242 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube EVU Sperre aktiv | |
slave: 1 | |
unique_id: ventcube_evu_sperre_aktiv | |
address: 243 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Wartungstür offen | |
slave: 1 | |
unique_id: ventcube_wartungstur_offen | |
address: 244 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Gerätefilter verschmutzt | |
slave: 1 | |
unique_id: ventcube_geratefilter_verschmutzt | |
address: 245 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Vorgelagerter Filter verschmutzt | |
slave: 1 | |
unique_id: ventcube_vorgelagerter_filter_verschmutzt | |
address: 246 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Zuluft zu kalt | |
slave: 1 | |
unique_id: ventcube_zuluft_zu_kalt | |
address: 254 | |
# Translated with template sensor (binary_sensor) | |
- name: VentCube Restlaufzeit Gerätefilter | |
slave: 1 | |
unique_id: ventcube_restlaufzeit_geratefilter | |
address: 265 | |
unit_of_measurement: d | |
min_value: 0 | |
max_value: 255 | |
device_class: duration | |
- name: VentCube Temperatur Wohnzimmer IST | |
slave: 1 | |
unique_id: ventcube_temperatur_wohnzimmer_ist | |
unit_of_measurement: °C | |
device_class: temperature | |
address: 360 | |
scale: 0.1 | |
precision: 1 | |
min_value: 0 | |
max_value: 100 | |
switches: | |
- name: VentCube Freigabe WP auf Heizen | |
slave: 1 | |
address: 231 | |
command_on: 0x1 # Freigabe | |
command_off: 0x0 # Gesperrt | |
write_type: holdings | |
verify: | |
input_type: holding | |
state_on: 0x1 | |
state_off: 0x0 | |
delay: 5 | |
unique_id: ventcube_set_waermepumpe_heizen | |
- name: VentCube Freigabe WP auf Kühlen | |
slave: 1 | |
address: 232 | |
command_on: 0x1 # Freigabe | |
command_off: 0x0 # Gesperrt | |
write_type: holdings | |
verify: | |
input_type: holding | |
state_on: 0x1 | |
state_off: 0x0 | |
delay: 5 | |
unique_id: ventcube_set_waermepumpe_kuehlen | |
climates: | |
- name: "VentCube Soll-Temperatur" | |
unique_id: ventcube_soll_temperatur | |
slave: 1 | |
address: 400 | |
max_temp: 30 | |
min_temp: 10 | |
offset: 0 | |
precision: 0 | |
scale: 0.1 | |
target_temp_register: 400 | |
target_temp_write_registers: true | |
temp_step: 1 | |
temperature_unit: °C | |
- name: "VentCube Basis-Temperatur" | |
unique_id: ventcube_basis_temperatur | |
slave: 1 | |
address: 420 | |
max_temp: 30 | |
min_temp: 18 | |
offset: 0 | |
precision: 0 | |
scale: 0.1 | |
target_temp_register: 420 | |
target_temp_write_registers: true | |
temp_step: 1 | |
temperature_unit: °C | |
##################################################### | |
# Select Options which require separate Automations # | |
##################################################### | |
input_select: | |
ventcube_manuelle_luftstufe: | |
name: VentCube Manuelle Luftstufe | |
options: | |
- "0 - Aus" | |
- "1 - Stufe 1" | |
- "2 - Stufe 2" | |
- "3 - Stufe 3" | |
- "4 - Stufe 4" | |
- "5 - Automatik" | |
- "6 - Linearbetrieb" | |
icon: mdi:fan | |
ventcube_betriebsart: | |
name: VentCube Betriebsart | |
options: | |
- "0 - Aus" | |
- "1 - Handbetrieb" | |
- "2 - Winterbetrieb" | |
- "3 - Sommerbetrieb" | |
- "4 - Sommer Abluft" | |
icon: mdi:fan | |
ventcube_heiz_kuehlfunktion: | |
name: VentCube Heiz- Kühlfunktion | |
options: | |
- "0 - Aus" | |
- "1 - Heizen" | |
- "2 - Kühlen" | |
- "3 - Auto T-Außen" | |
- "4 - Auto Digitaler Eingang" | |
icon: mdi:fan | |
#################### | |
# TEMPLATE SENSORS # | |
#################### | |
sensor: | |
- platform: template | |
sensors: | |
ventcube_betriebsart_text: | |
unique_id: ventcube_betriebsart_text | |
friendly_name: "VentCube Betriebsart" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'Handbetrieb', | |
'2': 'Winterbetrieb', | |
'3': 'Sommerbetrieb', | |
'4': 'Sommer Abluft'} %} | |
{% set state = states.sensor.ventcube_betriebsart.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_bypass_zustand_text: | |
unique_id: ventcube_bypass_zustand_text | |
friendly_name: "VentCube Zustand Bypass" | |
value_template: > | |
{% set mapper = { | |
'0': 'Geschlossen', | |
'1': 'Offen (Kühlen)', | |
'2': 'Offen (Heizen)'} %} | |
{% set state = states.sensor.ventcube_bypass_zustand.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_zustand_aussenklappe_text: | |
unique_id: ventcube_zustand_aussenklappe_text | |
friendly_name: "VentCube Zustand Außenklappe" | |
value_template: > | |
{% set mapper = { | |
'0': 'Geschlossen', | |
'1': 'Offen'} %} | |
{% set state = states.sensor.ventcube_zustand_aussenklappe.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_waermepumpe_text: | |
unique_id: ventcube_status_waermepumpe_text | |
friendly_name: "VentCube Status Wärmepumpe" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'5': 'WP Heizen', | |
'49': 'WP Kühlen'} %} | |
{% set state = states.sensor.ventcube_status_waermepumpe.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_heiz_kuehlfunktion_text: | |
unique_id: ventcube_heiz_kuehlfunktion_text | |
friendly_name: "VentCube Status Heiz- Kühlfunktion" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'Heizen', | |
'2': 'Kühlen', | |
'3': 'Auto T-Außen', | |
'4': 'Auto Digitaler Eingang'} %} | |
{% set state = states.sensor.ventcube_heiz_kuehlfunktion.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_nachheizregister_text: | |
unique_id: ventcube_status_nachheizregister_text | |
friendly_name: "VentCube Status Nachheizregister" | |
value_template: > | |
{% set mapper = { | |
'0': 'Inaktiv', | |
'1': 'Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_nachheizregister.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_vorheizregister_text: | |
unique_id: ventcube_status_vorheizregister_text | |
friendly_name: "VentCube Status Vorheizregister" | |
value_template: > | |
{% set mapper = { | |
'0': 'Aus', | |
'1': 'VHR1 Aktiv', | |
'2': 'VHR2 Aktiv', | |
'3': 'VHR1+2 Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_vorheizregister.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_stosslueftung_text: | |
unique_id: ventcube_status_stosslueftung_text | |
friendly_name: "VentCube Status Stoßlüftung" | |
value_template: > | |
{% set mapper = { | |
'0': 'Inaktiv', | |
'1': 'Aktiv'} %} | |
{% set state = states.sensor.ventcube_status_stosslueftung.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_geblaese_zuluft_text: | |
unique_id: ventcube_status_geblaese_zuluft_text | |
friendly_name: "VentCube Status Gebläse Zuluft" | |
value_template: > | |
{% set mapper = { | |
'0': 'Deaktiviert', | |
'1': 'Anlaufphase', | |
'2': 'Aktiv', | |
'5': 'Standby', | |
'6': 'Fehler'} %} | |
{% set state = states.sensor.ventcube_status_geblaese_zuluft.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
ventcube_status_geblaese_abluft_text: | |
unique_id: ventcube_status_geblaese_abluft_text | |
friendly_name: "VentCube Status Gebläse Abluft" | |
value_template: > | |
{% set mapper = { | |
'0': 'Deaktiviert', | |
'1': 'Anlaufphase', | |
'2': 'Aktiv', | |
'5': 'Standby', | |
'6': 'Fehler'} %} | |
{% set state = states.sensor.ventcube_status_geblaese_abluft.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
template: | |
- binary_sensor: | |
- name: "VentCube Meldung Druckwächter Aktiv" | |
unique_id: ventcube_meldung_druckwachter_aktiv | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_druckwachter_aktiv.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung EVU Sperre aktiv" | |
unique_id: ventcube_meldung_evu_sperre_aktiv | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_evu_sperre_aktiv.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Wartungstür offen" | |
unique_id: ventcube_meldung_wartungstur_offen | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_wartungstur_offen.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Gerätefilter verschmutzt" | |
unique_id: ventcube_meldung_geratefilter_verschmutzt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_geratefilter_verschmutzt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Vorgelagerter Filter verschmutzt" | |
unique_id: ventcube_meldung_vorgelagerter_filter_verschmutzt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'on', | |
'1': 'off'} %} | |
{% set state = states.sensor.ventcube_vorgelagerter_filter_verschmutzt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
- name: "VentCube Meldung Zuluft Zu Kalt" | |
unique_id: ventcube_meldung_zuluft_zu_kalt | |
device_class: problem | |
state: > | |
{% set mapper = { | |
'0': 'off', | |
'1': 'on'} %} | |
{% set state = states.sensor.ventcube_zuluft_zu_kalt.state %} | |
{{ mapper[state] if state in mapper else 'Unknown' }} | |
Ich hab es noch nicht hinbekommen. Ich hatte es versucht ähnlich wie die Stoßlüftung zu programmieren, das geht aber nicht .
Kann bitte jemand erklären wie die Automation zum Setzten der ventcube_manuelle_luftstufe aussieht? Danke vorab :)
viii. Ab hier müsst ihr die Bildwerte anpassen, das hab ich selbst nur mit mühe und Not hinbekommen. Kann wer evtl die Anleitung weiterführen?
Das Bild wurde bei mir etwas klein und ich habe die ganzen Badges und das Bild rumgeschoben
Die Bildwerte müssen nicht angepasst werden.
Die Einrückungen müssen einfach genau wie in dem Template sein.
Dann funktioniert es direkt
Kann bitte jemand erklären wie die Automation zum Setzten der ventcube_manuelle_luftstufe aussieht? Danke vorab :)
hänge das an das ende der modbus_wgt.yaml mit dran.
automation BIC_VentCube:
- id: 'auto.ventcube_manuelle_luftstufe'
alias: VentCube Manuelle Luftstufe Auswahlfeld
triggers:
- entity_id:
- sensor.ventcube_manuelle_luftstufe
id: input
to:
trigger: state
- entity_id:
- input_select.ventcube_manuelle_luftstufe
id: select
to:
trigger: state
conditions: []
actions:
- choose:
- conditions:
- condition: trigger
id: input
sequence:
- variables:
index: '{{ trigger.to_state.state | int(0) }}'
- data:
option: '{{ state_attr("input_select.ventcube_manuelle_luftstufe", "options")[
index ] }}'
target:
entity_id: input_select.ventcube_manuelle_luftstufe
action: input_select.select_option
- conditions:
- condition: trigger
id: select
sequence:
- data_template:
address: 101
slave: 1
hub: BIC_VentCube
value:
- '{{ trigger.to_state.state[0] | int(0) }}'
action: modbus.write_register
mode: queued
max: 3
- id: 'auto..ventcube_betriebsart'
alias: VentCube Betriebsart Auswahlfeld
description: ''
triggers:
- entity_id:
- sensor.ventcube_betriebsart
id: input
to:
trigger: state
- entity_id:
- input_select.ventcube_betriebsart
id: select
to:
trigger: state
conditions: []
actions:
- choose:
- conditions:
- condition: trigger
id: input
sequence:
- variables:
index: '{{ trigger.to_state.state | int(0) }}'
- data:
option: '{{ state_attr("input_select.ventcube_betriebsart", "options")[
index ] }}'
target:
entity_id: input_select.ventcube_betriebsart
action: input_select.select_option
- conditions:
- condition: trigger
id: select
sequence:
- data_template:
address: 100
slave: 1
hub: BIC_VentCube
value:
- '{{ trigger.to_state.state[0] | int(0) }}'
- 0
action: modbus.write_register
mode: queued
max: 5
Alternativ
- Homeassistant UI aufrufen
- Einstellungen
- Automationen & Szenen
- Automation erstellen
- Neue Automation
- Rechts oben auf die drei Punkte und in YAML Modus wechseln
- Die Vorlagen @JavanXD reinwerfen (einzeln)
- Fertig
Ich bin neu mit HA unterwegs und verstehe nicht ganz warum er es nicht in seine yaml direkt mit aufgenommen hat, das könnte eventuell jemand anderes oder direkt javan aufklären aber beide Wege funktionieren.
Hallo Leute,
gibt es eigentlich mittlerweile eine Lösung für die genannte Boost Funktion?
Vielen Dank!