Save JavanXD/a3e8911e69f3a27a81eeeb80414bb6ab to your computer and use it in GitHub Desktop.
| # Helpful information: | |
| # https://github.com/Excodibur/ioBroker.schwoerer-ventcube/blob/master/src/lib/schwoerer/parameters.ts | |
| # https://github.com/fgoettel/wgt/blob/main/wgt/lueftungsanlage.py | |
| # https://knx-user-forum.de/forum/öffentlicher-bereich/knx-eib-forum/diy-do-it-yourself/1822296-modbus-schwörer-heizung?p=1906252#post1906252 | |
| ################## | |
| # MODBUS SENSORS # | |
| ################## | |
| modbus: | |
| - name: BIC_VentCube | |
| delay: 2 | |
| timeout: 3 | |
| type: tcp | |
| host: !secret wgt_ip | |
| port: 502 | |
| sensors: | |
| - name: VentCube Betriebsart | |
| slave: 1 | |
| unique_id: ventcube_betriebsart | |
| address: 100 | |
| # Translated with template sensor | |
| # Translated with input_select Automation | |
| - name: VentCube Manuelle Luftstufe | |
| slave: 1 | |
| unique_id: ventcube_manuelle_luftstufe | |
| address: 101 | |
| # Translated with input_select Automation | |
| - name: VentCube Aktuelle Luftstufe | |
| slave: 1 | |
| unique_id: ventcube_aktuelle_luftstufe | |
| address: 102 | |
| - name: VentCube Status Stoßlüftung | |
| slave: 1 | |
| unique_id: ventcube_status_stosslueftung | |
| address: 111 | |
| # Translated with template sensor | |
| - name: VentCube Restlaufzeit Stoßlüftung | |
| slave: 1 | |
| unique_id: ventcube_restlaufzeit_stosslueftung | |
| address: 112 | |
| unit_of_measurement: min | |
| device_class: duration | |
| min_value: 0 | |
| max_value: 60 | |
| - name: VentCube Status Wärmepumpe | |
| slave: 1 | |
| unique_id: ventcube_status_waermepumpe | |
| address: 114 | |
| # Translated with template sensor | |
| - name: VentCube Status Nachheizregister | |
| slave: 1 | |
| unique_id: ventcube_status_nachheizregister | |
| address: 116 | |
| # Translated with template sensor | |
| - name: VentCube Status Gebläse Zuluft | |
| slave: 1 | |
| unique_id: ventcube_status_geblaese_zuluft | |
| address: 117 | |
| # Translated with template sensor | |
| - name: VentCube Status Gebläse Abluft | |
| slave: 1 | |
| unique_id: ventcube_status_geblaese_abluft | |
| address: 118 | |
| # Translated with template sensor | |
| - name: VentCube Bypass Zustand | |
| slave: 1 | |
| unique_id: ventcube_bypass_zustand | |
| address: 123 | |
| # Translated with template sensor | |
| - name: VentCube Zustand Außenklappe | |
| slave: 1 | |
| unique_id: ventcube_zustand_aussenklappe | |
| address: 131 | |
| # Translated with template sensor | |
| - name: VentCube Status Vorheizregister | |
| slave: 1 | |
| unique_id: ventcube_status_vorheizregister | |
| address: 133 | |
| # Translated with template sensor | |
| - name: VentCube aktuelle Luftleistung Zuluft | |
| slave: 1 | |
| unique_id: ventcube_aktuelle_luftleistung_zuluft | |
| address: 142 | |
| state_class: measurement | |
| unit_of_measurement: "%" | |
| min_value: 0 | |
| max_value: 100 | |
| scale: 1 | |
| precision: 0 | |
| - name: VentCube aktuelle Luftleistung Abluft | |
| unique_id: ventcube_aktuelle_luftleistung_abluft | |
| slave: 1 | |
| address: 143 | |
| state_class: measurement | |
| unit_of_measurement: "%" | |
| min_value: 0 | |
| max_value: 100 | |
| scale: 1 | |
| precision: 0 | |
| - name: VentCube aktuelle Drehzahl Zuluft | |
| unique_id: ventcube_aktuelle_drehzahl_zuluft | |
| slave: 1 | |
| address: 144 | |
| state_class: measurement | |
| unit_of_measurement: "rpm" | |
| min_value: 0 | |
| max_value: 10000 | |
| precision: 0 | |
| - name: VentCube aktuelle Drehzahl Abluft | |
| unique_id: ventcube_aktuelle_drehzahl_abluft | |
| slave: 1 | |
| address: 145 | |
| state_class: measurement | |
| unit_of_measurement: "rpm" | |
| min_value: 0 | |
| max_value: 10000 | |
| precision: 0 | |
| - name: VentCube T2 Temperatur nach Vorheizregister | |
| slave: 1 | |
| unique_id: ventcube_t2_temperatur_nach_vorheizregister | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 201 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T3 Temperatur vor Nacherwärmung | |
| slave: 1 | |
| unique_id: ventcube_t3_temperatur_vor_nacherwaermung | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 202 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T4 Temperatur nach Nacherwärmung | |
| slave: 1 | |
| unique_id: ventcube_t4_temperatur_nach_nacherwaermung | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 203 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T5 Temperatur Abluft | |
| slave: 1 | |
| unique_id: ventcube_t5_temperatur_abluft | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 204 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T6 Temperatur im Wärmetauscher | |
| slave: 1 | |
| unique_id: ventcube_t6_temperatur_im_waermetauscher | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 205 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube T10 Temperatur Außen | |
| slave: 1 | |
| unique_id: ventcube_t10_temperatur_aussen | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 209 | |
| scale: 0.1 | |
| precision: 1 | |
| - name: VentCube Heiz- Kühlfunktion | |
| slave: 1 | |
| unique_id: ventcube_heiz_kuehlfunktion | |
| address: 230 | |
| # Translated with template sensor | |
| # Translated with input_select Automation | |
| - name: VentCube Wärmepumpe Heizen | |
| slave: 1 | |
| unique_id: ventcube_wp_heizen | |
| address: 231 | |
| - name: VentCube Wärmepumpe Kühlen | |
| slave: 1 | |
| unique_id: ventcube_wp_kuehlen | |
| address: 232 | |
| - name: VentCube Druckwächter aktiv | |
| slave: 1 | |
| unique_id: ventcube_druckwachter_aktiv | |
| address: 242 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube EVU Sperre aktiv | |
| slave: 1 | |
| unique_id: ventcube_evu_sperre_aktiv | |
| address: 243 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Wartungstür offen | |
| slave: 1 | |
| unique_id: ventcube_wartungstur_offen | |
| address: 244 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Gerätefilter verschmutzt | |
| slave: 1 | |
| unique_id: ventcube_geratefilter_verschmutzt | |
| address: 245 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Vorgelagerter Filter verschmutzt | |
| slave: 1 | |
| unique_id: ventcube_vorgelagerter_filter_verschmutzt | |
| address: 246 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Zuluft zu kalt | |
| slave: 1 | |
| unique_id: ventcube_zuluft_zu_kalt | |
| address: 254 | |
| # Translated with template sensor (binary_sensor) | |
| - name: VentCube Restlaufzeit Gerätefilter | |
| slave: 1 | |
| unique_id: ventcube_restlaufzeit_geratefilter | |
| address: 265 | |
| unit_of_measurement: d | |
| min_value: 0 | |
| max_value: 255 | |
| device_class: duration | |
| - name: VentCube Temperatur Wohnzimmer IST | |
| slave: 1 | |
| unique_id: ventcube_temperatur_wohnzimmer_ist | |
| unit_of_measurement: °C | |
| device_class: temperature | |
| address: 360 | |
| scale: 0.1 | |
| precision: 1 | |
| min_value: 0 | |
| max_value: 100 | |
| switches: | |
| - name: VentCube Freigabe WP auf Heizen | |
| slave: 1 | |
| address: 231 | |
| command_on: 0x1 # Freigabe | |
| command_off: 0x0 # Gesperrt | |
| write_type: holdings | |
| verify: | |
| input_type: holding | |
| state_on: 0x1 | |
| state_off: 0x0 | |
| delay: 5 | |
| unique_id: ventcube_set_waermepumpe_heizen | |
| - name: VentCube Freigabe WP auf Kühlen | |
| slave: 1 | |
| address: 232 | |
| command_on: 0x1 # Freigabe | |
| command_off: 0x0 # Gesperrt | |
| write_type: holdings | |
| verify: | |
| input_type: holding | |
| state_on: 0x1 | |
| state_off: 0x0 | |
| delay: 5 | |
| unique_id: ventcube_set_waermepumpe_kuehlen | |
| climates: | |
| - name: "VentCube Soll-Temperatur" | |
| unique_id: ventcube_soll_temperatur | |
| slave: 1 | |
| address: 400 | |
| max_temp: 30 | |
| min_temp: 10 | |
| offset: 0 | |
| precision: 0 | |
| scale: 0.1 | |
| target_temp_register: 400 | |
| target_temp_write_registers: true | |
| temp_step: 1 | |
| temperature_unit: °C | |
| - name: "VentCube Basis-Temperatur" | |
| unique_id: ventcube_basis_temperatur | |
| slave: 1 | |
| address: 420 | |
| max_temp: 30 | |
| min_temp: 18 | |
| offset: 0 | |
| precision: 0 | |
| scale: 0.1 | |
| target_temp_register: 420 | |
| target_temp_write_registers: true | |
| temp_step: 1 | |
| temperature_unit: °C | |
| ##################################################### | |
| # Select Options which require separate Automations # | |
| ##################################################### | |
| input_select: | |
| ventcube_manuelle_luftstufe: | |
| name: VentCube Manuelle Luftstufe | |
| options: | |
| - "0 - Aus" | |
| - "1 - Stufe 1" | |
| - "2 - Stufe 2" | |
| - "3 - Stufe 3" | |
| - "4 - Stufe 4" | |
| - "5 - Automatik" | |
| - "6 - Linearbetrieb" | |
| icon: mdi:fan | |
| ventcube_betriebsart: | |
| name: VentCube Betriebsart | |
| options: | |
| - "0 - Aus" | |
| - "1 - Handbetrieb" | |
| - "2 - Winterbetrieb" | |
| - "3 - Sommerbetrieb" | |
| - "4 - Sommer Abluft" | |
| icon: mdi:fan | |
| ventcube_heiz_kuehlfunktion: | |
| name: VentCube Heiz- Kühlfunktion | |
| options: | |
| - "0 - Aus" | |
| - "1 - Heizen" | |
| - "2 - Kühlen" | |
| - "3 - Auto T-Außen" | |
| - "4 - Auto Digitaler Eingang" | |
| icon: mdi:fan | |
| #################### | |
| # TEMPLATE SENSORS # | |
| #################### | |
| sensor: | |
| - platform: template | |
| sensors: | |
| ventcube_betriebsart_text: | |
| unique_id: ventcube_betriebsart_text | |
| friendly_name: "VentCube Betriebsart" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'Handbetrieb', | |
| '2': 'Winterbetrieb', | |
| '3': 'Sommerbetrieb', | |
| '4': 'Sommer Abluft'} %} | |
| {% set state = states.sensor.ventcube_betriebsart.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_bypass_zustand_text: | |
| unique_id: ventcube_bypass_zustand_text | |
| friendly_name: "VentCube Zustand Bypass" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Geschlossen', | |
| '1': 'Offen (Kühlen)', | |
| '2': 'Offen (Heizen)'} %} | |
| {% set state = states.sensor.ventcube_bypass_zustand.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_zustand_aussenklappe_text: | |
| unique_id: ventcube_zustand_aussenklappe_text | |
| friendly_name: "VentCube Zustand Außenklappe" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Geschlossen', | |
| '1': 'Offen'} %} | |
| {% set state = states.sensor.ventcube_zustand_aussenklappe.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_waermepumpe_text: | |
| unique_id: ventcube_status_waermepumpe_text | |
| friendly_name: "VentCube Status Wärmepumpe" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '5': 'WP Heizen', | |
| '49': 'WP Kühlen'} %} | |
| {% set state = states.sensor.ventcube_status_waermepumpe.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_heiz_kuehlfunktion_text: | |
| unique_id: ventcube_heiz_kuehlfunktion_text | |
| friendly_name: "VentCube Status Heiz- Kühlfunktion" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'Heizen', | |
| '2': 'Kühlen', | |
| '3': 'Auto T-Außen', | |
| '4': 'Auto Digitaler Eingang'} %} | |
| {% set state = states.sensor.ventcube_heiz_kuehlfunktion.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_nachheizregister_text: | |
| unique_id: ventcube_status_nachheizregister_text | |
| friendly_name: "VentCube Status Nachheizregister" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Inaktiv', | |
| '1': 'Aktiv'} %} | |
| {% set state = states.sensor.ventcube_status_nachheizregister.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_vorheizregister_text: | |
| unique_id: ventcube_status_vorheizregister_text | |
| friendly_name: "VentCube Status Vorheizregister" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Aus', | |
| '1': 'VHR1 Aktiv', | |
| '2': 'VHR2 Aktiv', | |
| '3': 'VHR1+2 Aktiv'} %} | |
| {% set state = states.sensor.ventcube_status_vorheizregister.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_stosslueftung_text: | |
| unique_id: ventcube_status_stosslueftung_text | |
| friendly_name: "VentCube Status Stoßlüftung" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Inaktiv', | |
| '1': 'Aktiv'} %} | |
| {% set state = states.sensor.ventcube_status_stosslueftung.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_geblaese_zuluft_text: | |
| unique_id: ventcube_status_geblaese_zuluft_text | |
| friendly_name: "VentCube Status Gebläse Zuluft" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Deaktiviert', | |
| '1': 'Anlaufphase', | |
| '2': 'Aktiv', | |
| '5': 'Standby', | |
| '6': 'Fehler'} %} | |
| {% set state = states.sensor.ventcube_status_geblaese_zuluft.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| ventcube_status_geblaese_abluft_text: | |
| unique_id: ventcube_status_geblaese_abluft_text | |
| friendly_name: "VentCube Status Gebläse Abluft" | |
| value_template: > | |
| {% set mapper = { | |
| '0': 'Deaktiviert', | |
| '1': 'Anlaufphase', | |
| '2': 'Aktiv', | |
| '5': 'Standby', | |
| '6': 'Fehler'} %} | |
| {% set state = states.sensor.ventcube_status_geblaese_abluft.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| template: | |
| - binary_sensor: | |
| - name: "VentCube Meldung Druckwächter Aktiv" | |
| unique_id: ventcube_meldung_druckwachter_aktiv | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_druckwachter_aktiv.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung EVU Sperre aktiv" | |
| unique_id: ventcube_meldung_evu_sperre_aktiv | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_evu_sperre_aktiv.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Wartungstür offen" | |
| unique_id: ventcube_meldung_wartungstur_offen | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_wartungstur_offen.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Gerätefilter verschmutzt" | |
| unique_id: ventcube_meldung_geratefilter_verschmutzt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_geratefilter_verschmutzt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Vorgelagerter Filter verschmutzt" | |
| unique_id: ventcube_meldung_vorgelagerter_filter_verschmutzt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'on', | |
| '1': 'off'} %} | |
| {% set state = states.sensor.ventcube_vorgelagerter_filter_verschmutzt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
| - name: "VentCube Meldung Zuluft Zu Kalt" | |
| unique_id: ventcube_meldung_zuluft_zu_kalt | |
| device_class: problem | |
| state: > | |
| {% set mapper = { | |
| '0': 'off', | |
| '1': 'on'} %} | |
| {% set state = states.sensor.ventcube_zuluft_zu_kalt.state %} | |
| {{ mapper[state] if state in mapper else 'Unknown' }} | |
Ich hab es noch nicht hinbekommen. Ich hatte es versucht ähnlich wie die Stoßlüftung zu programmieren, das geht aber nicht .
Kann bitte jemand erklären wie die Automation zum Setzten der ventcube_manuelle_luftstufe aussieht? Danke vorab :)
viii. Ab hier müsst ihr die Bildwerte anpassen, das hab ich selbst nur mit mühe und Not hinbekommen. Kann wer evtl die Anleitung weiterführen?
Das Bild wurde bei mir etwas klein und ich habe die ganzen Badges und das Bild rumgeschoben
Die Bildwerte müssen nicht angepasst werden.
Die Einrückungen müssen einfach genau wie in dem Template sein.
Dann funktioniert es direkt
Kann bitte jemand erklären wie die Automation zum Setzten der ventcube_manuelle_luftstufe aussieht? Danke vorab :)
hänge das an das ende der modbus_wgt.yaml mit dran.
automation BIC_VentCube:
- id: 'auto.ventcube_manuelle_luftstufe'
alias: VentCube Manuelle Luftstufe Auswahlfeld
triggers:
- entity_id:
- sensor.ventcube_manuelle_luftstufe
id: input
to:
trigger: state
- entity_id:
- input_select.ventcube_manuelle_luftstufe
id: select
to:
trigger: state
conditions: []
actions:
- choose:
- conditions:
- condition: trigger
id: input
sequence:
- variables:
index: '{{ trigger.to_state.state | int(0) }}'
- data:
option: '{{ state_attr("input_select.ventcube_manuelle_luftstufe", "options")[
index ] }}'
target:
entity_id: input_select.ventcube_manuelle_luftstufe
action: input_select.select_option
- conditions:
- condition: trigger
id: select
sequence:
- data_template:
address: 101
slave: 1
hub: BIC_VentCube
value:
- '{{ trigger.to_state.state[0] | int(0) }}'
action: modbus.write_register
mode: queued
max: 3
- id: 'auto..ventcube_betriebsart'
alias: VentCube Betriebsart Auswahlfeld
description: ''
triggers:
- entity_id:
- sensor.ventcube_betriebsart
id: input
to:
trigger: state
- entity_id:
- input_select.ventcube_betriebsart
id: select
to:
trigger: state
conditions: []
actions:
- choose:
- conditions:
- condition: trigger
id: input
sequence:
- variables:
index: '{{ trigger.to_state.state | int(0) }}'
- data:
option: '{{ state_attr("input_select.ventcube_betriebsart", "options")[
index ] }}'
target:
entity_id: input_select.ventcube_betriebsart
action: input_select.select_option
- conditions:
- condition: trigger
id: select
sequence:
- data_template:
address: 100
slave: 1
hub: BIC_VentCube
value:
- '{{ trigger.to_state.state[0] | int(0) }}'
- 0
action: modbus.write_register
mode: queued
max: 5
Alternativ
- Homeassistant UI aufrufen
- Einstellungen
- Automationen & Szenen
- Automation erstellen
- Neue Automation
- Rechts oben auf die drei Punkte und in YAML Modus wechseln
- Die Vorlagen @JavanXD reinwerfen (einzeln)
- Fertig
Ich bin neu mit HA unterwegs und verstehe nicht ganz warum er es nicht in seine yaml direkt mit aufgenommen hat, das könnte eventuell jemand anderes oder direkt javan aufklären aber beide Wege funktionieren.
Danke Dir für das tolle Bild! So sieht's bei mir aktuell aus.
@JavanXD würfest du die Yaml für dieses Dashboard teilen? :) das wäre super lieb
Hello ;)
für mich ist das mit Modus und Co noch relatives Neuland. Habe jetzt aber im Grunde die Schritte wie beschrieben ausgeführt. Bekomme jedoch bei "Entwicklerwerkzeuge" -> "YAML" bei Konfiguration prüfen folgende Fehlermeldung.
Konfigurationswarnungen
Invalid config for 'modbus' at configuration.yaml, line 12: 'input_select' is an invalid option for 'modbus', check: modbus->0->input_select
Invalid config for 'modbus' at configuration.yaml, line 12: 'modbus' is an invalid option for 'modbus', check: modbus->0->modbus
Invalid config for 'modbus' at configuration.yaml, line 12: 'sensor' is an invalid option for 'modbus', check: modbus->0->sensor
Invalid config for 'modbus' at configuration.yaml, line 12: 'template' is an invalid option for 'modbus', check: modbus->0->template
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'baudrate' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'bytesize' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'method' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'parity' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'port' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'stopbits' not provided
Invalid config for 'modbus' at configuration.yaml, line 12: required key 'type' not provided
Hat jemand ne Idee und kann mir hier weiterhelfen? Danke vorab
Grüße
Dani
Hallo zusammen, aktuell läuft bei mir fast alles seht gut, nur leider funktioniert die manuelle Auswahl der Betriebsart & Luftstufe nicht. Gibt es hier einen separaten Code für für Auswahl Drop-Down-Liste ? Wie muss das konfiguriert werden ?
In Home Assistant kannst du nicht direkt in einen modbus sensor schreiben, da sensors grundsätzlich nur lesend arbeiten.
Um einen Wert an ein Modbus-Gerät zu schreiben, musst du stattdessen eine modbus.write_register -Service-Call verwenden – entweder in einer Automation, einem Script oder über eine UI-Button-Action.
Siehe den Kommentar von @ForumSchlampe https://gist.github.com/JavanXD/a3e8911e69f3a27a81eeeb80414bb6ab?permalink_comment_id=5554989#gistcomment-5554989
Hi Javan, fettes Dankeschön erstmal für die Mühe hier alles niederzuschreiben.
Ich hab jetzt erstmal deine YAML Codes in meine HA Installation importiert und das meiste funktioniert soweit schon ganz gut.
Ich habe auch dank der verlinkten Dokumentationen zu weiteren Modbus Adressen die Climates für die anderen Räume ergänzen können.
Was bei mir aber nicht funktioniert, ist die Übersetzung mancher Zustände:

Auch der Status der WP (wir haben die WRG134BP/HK, nicht den VentCube) funktioniert auf die gleiche Weise nicht.
Obwohl der numerische Sensorwert korrekt angezeigt wird und die Übersetzungstabelle natürlich diesen Wert übersetzen müsste, ist der Template-Sensor in beiden Fällen dauerhaft auf "UNKNOWN".
wgt_betriebsart_text oder wgt_bypass_zustand_text funktionieren dagegen wie gewollt. Ich verstehe es nicht.
Der Code funktioniert weder 1:1 von dir kopiert, noch wenn ich ihn von einem der funktionierenden Abschnitte kopiere und inhaltlich abändere...
wgt_status_waermepumpe_text:
unique_id: wgt_status_waermepumpe_text
friendly_name: "WGT Status Wärmepumpe"
value_template: >
{% set mapper = {
'0': 'Aus',
'5': 'WP Heizen',
'49': 'WP Kühlen'} %}
{% set state = states.sensor.wgt_status_waermepumpe.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
wgt_heizen_kuehlen_text:
unique_id: wgt_heizen_kuehlen_text
friendly_name: "WGT Status Heiz-Kühlfunktion"
value_template: >
{% set mapper = {
'0': 'Aus',
'1': 'Heizen',
'2': 'Kühlen',
'3': 'Auto T-Außen',
'4': 'Auto Digitaleingang'} %}
{% set state = states.sensor.wgt_heiz_kuehlfunktion.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
Weißt du woran es liegen könnte?
Und noch eine Frage: Die Climates funktionieren zwar für alle Räume, aber im Dashboard verstehe ich die Thermostat-Anzeige so, dass auf dem Regler die Solltemperatur eingestellt werden soll und darunter klein die IST-Temperatur dargestellt werden soll. Letzteres stimmt aber nicht. Hier wird der Status auf derselben Adresse abgegriffen, also auch die im System hinterlegte Soll-Temperatur. Die IST-Temperaturen müssten anstatt auf den Adressen 400...416 auf den Adressen 360...374 liegen. Aber wie kriege ich diese Werte in die Anzeige?
Bei mir das selbe Problem,
sensor.ventcube_bypass_zustand_text sensor.ventcube_status_geblaese_abluft_text sensor.ventcube_status_geblaese_zuluft_text sensor.ventcube_status_stosslueftung_text sensor.ventcube_status_waermepumpe_text
werden alle als unknown angezeigt.
sensor.ventcube_zustand_aussenklappe_text sensor.ventcube_status_vorheizregister_text sensor.ventcube_status_nachheizregister_text sensor.ventcube_betriebsart_text
Funktionieren hingegen einwandfrei.
Konnte im Code leider auch keinen Fehler entdecken.
Und noch eine Frage: Die Climates funktionieren zwar für alle Räume, aber im Dashboard verstehe ich die Thermostat-Anzeige so, dass auf dem Regler die Solltemperatur eingestellt werden soll und darunter klein die IST-Temperatur dargestellt werden soll. Letzteres stimmt aber nicht. Hier wird der Status auf derselben Adresse abgegriffen, also auch die im System hinterlegte Soll-Temperatur. Die IST-Temperaturen müssten anstatt auf den Adressen 400...416 auf den Adressen 360...374 liegen. Aber wie kriege ich diese Werte in die Anzeige?
Immerhin, dazu hab ich jetzt selbst einen Fix gefunden:
Und zwar ist es falsch für address und target_temp_register dieselbe Addresse zu setzen.
Stattdessen sollte für eine ordnungsgemäße Eintitätsanzeige als Thermostat im Dashboard bei "address" eine aus der Ist-Temperatur Range gewählt werden. Außerdem die Precision auf 1 statt 0.
- name: "Soll-Temperatur Raum 1"
unique_id: ventcube_soll_temperatur_raum1
slave: 1
address: 360
max_temp: 30
min_temp: 10
offset: 0
precision: 1
scale: 0.1
target_temp_register: 400
target_temp_write_registers: true
temp_step: 1
temperature_unit: °C
Bei mir das selbe Problem,
sensor.ventcube_bypass_zustand_text sensor.ventcube_status_geblaese_abluft_text sensor.ventcube_status_geblaese_zuluft_text sensor.ventcube_status_stosslueftung_text sensor.ventcube_status_waermepumpe_textwerden alle als unknown angezeigt.
sensor.ventcube_zustand_aussenklappe_text sensor.ventcube_status_vorheizregister_text sensor.ventcube_status_nachheizregister_text sensor.ventcube_betriebsart_textFunktionieren hingegen einwandfrei.
Konnte im Code leider auch keinen Fehler entdecken.
Juhuuu! Ich hab es dank Google Gemini geschafft.
Und zwar scheint HA manchmal abweichende Entitäts-IDs zu erstellen. Das muss man über Entwicklerwerkzeuge -> Zustände mit dem Code des Templates abgleichen. Da kommt es scheinbar manchmal zu einem Mismatch und dann fragt der Template Code einen Entitätszustand ab, der nicht existiert.
Konkretes Beispiel bei mir:
a) im YAML Code hinterlegt für den Sensor Heiz-Kühlfunktion ist
unique_id: wgt_heiz_kuehlfunktion
b) im Template wird auf denselben Namen aufgerufen
{%`` set state = states.sensor.wgt_heiz_kuehlfunktion.state %}
Das funktioniert aber nicht, da die Entität anders heißt, nämlich ohne das e:

Wieso HA das so manchmal macht, ist mir schleierhaft. Vielleicht hat die unique_id aber auch nichts mit dem Entitätsnamen zu tun. Wie der dann generiert wird, ist mir aber auch unklar. Bei Korrektur von b) auf folgendes funktioniert das Template dann aber wie gewollt:
{%`` set state = states.sensor.wgt_heiz_kuhlfunktion.state %}
Hallo zusammen, ich bin ziemlich neu in der HA Welt. Wie habt ihr die einzelnen Räume wie Kinderzimmer, Wohnzimmer usw. im HA integriert?
Wäre es generell möglich hier eine Automation o.ä. zu erstellen mit PV?
Es wird geheizt wenn PV den Wert X erreicht und somit die Wärmepumpe mit Zusatzheizung angeht?
Hallo zusammen, ich bin ziemlich neu in der HA Welt. Wie habt ihr die einzelnen Räume wie Kinderzimmer, Wohnzimmer usw. im HA integriert?
Wäre es generell möglich hier eine Automation o.ä. zu erstellen mit PV? Es wird geheizt wenn PV den Wert X erreicht und somit die Wärmepumpe mit Zusatzheizung angeht?
Prinzipiell ist in HA so ziemlich alles möglich sofern man die Werkzeuge dazu hat (Sensordaten und Co). Das heißt du musst das Smart-Meter der PV einbinden und dort die Werte abgreifen. Davon abhängig kannst du dann die Wärmepumpe sowie die ZH im Haus aktivieren lassen und bei Erreichen einer bestimmten Temperatur, oder wenn der HV-Batteriespeicher einen bestimmte Ladezustand unterschreitet, wieder ausschalten.
Hab ich aber bislang selber noch nicht gemacht. PV fehlt derzeit noch. Aber wenn es soweit ist, setze ich mich erstmal daran, den PV-Überschuss dem Heizstab von der elco zu spendieren. Legionellenschutz und so, über SGready aktivieren.






Hallo Leute,
gibt es eigentlich mittlerweile eine Lösung für die genannte Boost Funktion?
Vielen Dank!
Grüße!