POST
https://api.spanet.net.au/api/MemberLogin
Request:
{
"login": [Username],
"api_key": "4a483b9a-8f02-4e46-8bfa-0cf5732dbbd5",
"password": [Password]
}
Response:
{
"data": {
"email": null,
"id_member": [MemberId],
"login": [Username],
"name": null,
"password": null,
"notification_enabled": 1,
"id_session": [SessionId]
},
"error": null,
"error_code": null,
"message": null,
"success": true
}
GET
https://api.spanet.net.au/api/membersockets?id_member=[MemberId]&id_session=[SessionId]
Response:
{
"data": {
"email": null,
"id_member": 0,
"login": null,
"name": null,
"password": null,
"notification_enabled": 0,
"id_session": null
},
"sockets": [{
"id": [SocketId],
"active": "1",
"id_member": [MemberId],
"id_sockets": [SocketId],
"mac_addr": [MacAddress],
"moburl": [WebSocketUrl]:9090,
"name": [SpaName],
"spaurl": [WebSocketUrl]:9090,
"signalStrength": -69,
"error": false
}],
"error": null,
"error_code": null,
"message": "",
"success": true
}
Open TCP Socket to [WebUrl]
port 9090
, then send..
Request:
<connect--[SocketId]--[MemberId]>
Response:
Successfully connected
Get the current status of the spa.
Request:
RF\n
Sample Response:
RF:
,R2,18,250,51,70,4,13,50,55,19,6,2020,376,9999,1,0,490,207,34,6000,602,23,20,0,0,0,0,44,35,45,:
,R3,32,1,4,4,4,SW V5 17 05 31,SV3,18480001,20000826,1,0,0,0,0,0,NA,7,0,470,Filtering,4,0,7,7,0,0,:
,R4,NORM,0,0,0,1,0,3547,4,20,4500,7413,567,1686,0,8388608,0,0,5,0,98,0,10084,4,80,100,0,0,4,:
,R5,0,1,0,1,0,0,0,0,0,0,1,0,1,0,376,0,3,4,0,0,0,0,0,1,2,6,:
,R6,1,5,0,2,5,8,1,360,1,0,3584,5120,127,128,5632,5632,2304,1792,0,30,0,0,0,0,2,3,0,:
,R7,2304,0,1,1,1,0,1,0,0,0,253,191,253,240,483,125,77,1,0,0,0,23,200,1,0,1,31,32,35,100,5,:
,R9,F1,255,0,0,0,0,0,0,0,0,0,0,:
,RA,F2,0,0,0,0,0,0,255,0,0,0,0,:
,RB,F3,0,0,0,0,0,0,0,0,0,0,0,:
,RC,0,1,1,0,0,0,0,0,0,2,0,0,1,0,:
,RE,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,1,0,0,0,0,0,0,0,-4,13,30,8,5,1,0,0,0,0,0,:*
,RG,1,1,1,1,1,1,1-1-014,1-1-01,1-1-01,0-,0-,0,:*
Set the target temperature for the spa.
Request:
W40:nnn
Response:
nnn
where nnn
denotes temperature in celsius * 10 between 5.0
-41.0
c (ie: for 35.6c, nnn
= 356)
Start (or cancel) a Clean cycle.
Request:
W12
Response:
W12
Control Pump 1.
Request:
S22:n
Response:
S22-OK
where n
denotes
0
- Off1
- On4
- Auto
Control Pump 2.
Request:
S23:n
Response:
S23-OK
where n
denotes
0
- Off1
- On
Control Pump 3.
Request:
S24:n
Response:
S24-OK
where n
denotes
0
- Off1
- On
Control the Blower.
Request:
S28:n
Response:
S28-OK
where n
denotes
0
- Variable1
- Ramp2
- Off
Set the variable speed of the blower.
Request:
S13:n
Response:
n S13
where n
denotes speed 1
-5
TODO
Set the Operation mode.
Request:
W66:n
Response:
n
where n
denotes
0
- Norm1
- Econ2
- Away3
- Week
Set the filtration runtime.
Request:
W60:n
Response:
n
where n
denotes hours between 1
-24
.
Set the time between filtration cycles.
Request:
W90:n
Response:
n
where n
denotes hours as
1
- 1 hr2
- 2 hr3
- 3 hr4
- 4 hr6
- 6 hr8
- 8 hr12
- 12 hr24
- 24 hr
TODO
Set the Power Save option.
Request:
W63:n
Response:
n
where n
denotes
0
- Off1
- Low2
- High
TODO
TODO
TODO
TODO
TODO
Set the Lock Mode.
Request:
S21:n
Response:
n
where n
denotes
0
- Off1
- Partial2
- Full
TODO
@jbergler
Is there anything that you can share at this point?
The controller has inbuilt voltage & amp measurements. Have a look here https://github.com/wayne-love/spanet-api/blob/main/spanet.md, I've forked @BlaT2512's document and am adding to it as I discover stuff. I have a pile of additions (such as power consumption, etc) to add to this but real life is getting in the way. I'll do a pull once it is up to date to merge back to the original.