CLI Version = 007.1020.0000.0000 July 1, 2019
Operating system = Linux 3.10.0-693.el7.x86_64
Controller = 0
Status = Success
Description = None
Basics :
======
Controller = 0
Model = PERC H310 Mini
Serial Number = 41P027F
Current Controller Date/Time = 04/26/2021, 17:48:57
Current System Date/time = 04/26/2021, 17:49:10
SAS Address = 5c81f660e952ca00
PCI Address = 00:03:00:00
Mfg Date = 01/29/14
Rework Date = 01/29/14
Revision No = A06
Version :
=======
Firmware Package Build = 20.13.3-0001
Firmware Version = 2.121.14-6325
Bios Version = 4.37.00_4.12.05.00_0x05290003
Preboot CLI Version = 03.02-015:#%00008
Ctrl-R Version = 3.00-0026
NVDATA Version = 3.09.03-0039
Boot Block Version = 2.02.00.00-0001
Driver Name = megaraid_sas
Driver Version = 07.701.17.00-rh1
Bus :
===
Vendor Id = 0x1000
Device Id = 0x73
SubVendor Id = 0x1028
SubDevice Id = 0x1F51
Host Interface = PCI-E
Device Interface = SAS-6G
Bus Number = 3
Device Number = 0
Function Number = 0
Pending Images in Flash :
=======================
Image name = No pending images
Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = NA
PD Firmware Download in progress = No
Support PD Firmware Download = No
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No
Controller shutdown required = No
Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate = Yes
Reconstruction Rate = Yes
Patrol Read Rate = Yes
Alarm Control = Yes
Cluster Support = No
BBU = NA
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = No
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = No
Snapshot Enabled = No
Support PFK = No
Support PI = No
Support Ld BBM Info = No
Support Shield State = No
Block SSD Write Disk Cache Change = No
Support Suspend Resume BG ops = No
Support Emergency Spares = No
Support Set Link Speed = No
Support Boot Time PFK Change = No
Support SystemPD = No
Disable Online PFK Change = No
Support Perf Tuning = No
Support SSD PatrolRead = No
Real Time Scheduler = No
Support Reset Now = No
Support Emulated Drives = No
Headless Mode = No
Dedicated HotSpares Limited = No
Point In Time Progress = No
Extended LD = No
Support Uneven span = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = No
Support Ext Enclosure = No
Support Sesmonitoring = No
Support SecurityonJBOD = No
Support ForceFlash = No
Support DisableImmediateIO = No
Support LargeIOSupport = No
Support DrvActivityLEDSetting = No
Support FlushWriteVerify = No
Support CPLDUpdate = No
Support ForceTo512e = No
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support Ctrl Info Extended = No
Support IButton less = No
Support AES Encryption Algorithm = No
Support Encrypted MFC = No
Support Snapdump = No
Support Force Personality Change = No
Support Dual Fw Image = No
Support PSOC Update = No
Support Secure Boot = No
Support Clear Snapdump = No
Support Debug Queue = No
Support Least Latency Mode = Yes
Support OnDemand Snapdump = No
Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = Yes
Set Power State For Cfg = No
Support T10 Power State = Yes
Support Temperature = Yes
NCQ = No
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No
Support SSD Wear Gauge = No
Supported VD Operations :
=======================
Read Policy = No
Write Policy = No
IO Policy = No
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = Yes
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = Yes
Support Powersave Max With Cache = No
Support Breakmirror = Yes
Support SSC WriteBack = No
Support SSC Association = No
Support VD Hide = No
Support VD Cachebypass = No
Support VD discardCacheDuringLDDelete = No
Support VD Scsi Unmap = No
HwCfg :
=====
ChipRevision = B2
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Absent
Alarm = Missing
Serial Debugger = Present
NVRAM Size = 32KB
Flash Size = 16MB
On Board Memory Size = 0MB
CacheVault Flash Size = NA
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Present
Upgradable CPLD = Absent
Upgradable PSOC = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 0
ROC temperature(Degree Celsius) = 36
Ctrl temperature(Degree Celsius) = 36
Policies :
========
Policies Table :
==============
------------------------------------------------
Policy Current Default
------------------------------------------------
Predictive Fail Poll Interval 300 sec
Interrupt Throttle Active Count 16
Interrupt Throttle Completion 50 us
Rebuild Rate 30 % 30%
PR Rate 30 % 30%
BGI Rate 30 % 30%
Check Consistency Rate 30 % 30%
Reconstruction Rate 30 % 30%
Cache Flush Interval 4s
------------------------------------------------
Flush Time(Default) = 4s
Drive Coercion Mode = 128MB
Auto Rebuild = On
Battery Warning = Off
ECC Bucket Size = 15
ECC Bucket Leak Rate (hrs) = 24
Restore Hot Spare on Insertion = Off
Expose Enclosure Devices = Off
Maintain PD Fail History = Off
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off
Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = Yes
Enable Web BIOS = No
Enable PreBoot CLI = No
Enable BIOS = Yes
Max Drives to Spinup at One Time = 4
Maximum number of direct attached drives to spin up in 1 min = 20
Delay Among Spinup Groups (sec) = 12
Allow Boot with Preserved Cache = Off
High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No
Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 64 KB
Write Policy = WT
Read Policy = No Read Ahead
Cache When BBU Bad = Off
Cached IO = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 128 MB
ZCR Config = Unknown
Max Chained Enclosures = 4
Direct PD Mapping = Yes
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = No
Maintain PD Fail History = No
Zero Based Enclosure Enumeration = Yes
Disable Puncturing = No
EnableLDBBM = Yes
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = Yes
Dirty LED Shows Drive Activity = No
EnableCrashDump = No
Disable Online Controller Reset = No
Treat Single span R1E as R10 = Yes
Power Saving option = Enabled
TTY Log In Flash = Yes
Auto Enhanced Import = No
BreakMirror RAID Support = single span R1
Disable Join Mirror = Yes
Enable Shield State = No
Time taken to detect CME = 60 sec
Capabilities :
============
Supported Drives = SAS, SATA
RAID Level Supported = RAID0, RAID1, RAID5, RAID00, RAID10(2 or more drives per span), RAID50
Enable SystemPD = Yes
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Not Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 16
Max Spans Per VD = 8
Max Arrays = 16
Max VD per array = 16
Max Number of VDs = 16
Max Parallel Commands = 31
Max SGE Count = 60
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 20
Max Configurable CacheCade Size(GB) = 0
Max Transportable DGs = 0
Enable Snapdump = No
Enable SCSI Unmap = Yes
FDE Drive Mix Support = No
Min Strip Size = 64 KB
Max Strip Size = 64 KB
Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = NA
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 04/28/2021, 09:00:00
Battery learn Reoccurrence = NA
OEMID = Dell
Drive Groups = 1
TOPOLOGY :
========
-----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
-----------------------------------------------------------------------------
0 - - - - RAID1 Optl N 465.250 GB dflt N N dflt N N
0 0 - - - RAID1 Optl N 465.250 GB dflt N N dflt N N
0 0 0 32:0 0 DRIVE Onln N 465.250 GB dflt N N dflt - N
0 0 1 32:1 1 DRIVE Onln N 465.250 GB dflt N N dflt - N
-----------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 1
VD LIST :
=======
------------------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
------------------------------------------------------------------------
0/0 RAID1 Optl RW Yes NRWTD - OFF 465.250 GB Virtual Disk0
------------------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 2
PD LIST :
=======
------------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
------------------------------------------------------------------------------
32:0 0 Onln 0 465.250 GB SAS HDD N N 512B ST9500620SS U -
32:1 1 Onln 0 465.250 GB SAS HDD N N 512B ST9500620SS U -
------------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=Unsupported|UGShld=UnConfigured shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|rbld=Rebuild
Generating detailed summary of the adapter, it may take a while to complete.
CLI Version = 007.1020.0000.0000 July 1, 2019
Operating system = Linux 3.10.0-693.el7.x86_64
Controller = 1
Status = Success
Description = None
Basics :
======
Controller = 1
Model = PERC H810 Adapter
Serial Number = 42A00BT
Current Controller Date/Time = 04/26/2021, 17:48:44
Current System Date/time = 04/26/2021, 17:49:10
SAS Address = 5c81f660eba33800
PCI Address = 00:04:00:00
Mfg Date = 02/17/14
Rework Date = 02/17/14
Revision No = A03
Version :
=======
Firmware Package Build = 21.3.5-0002
Firmware Version = 3.131.05-8148
Bios Version = 5.42.00.1_4.12.05.00_0x05290003
Ctrl-R Version = 4.04-0003
Preboot CLI Version = 05.00-03:#%00008
NVDATA Version = 2.1108.03-0097
Boot Block Version = 2.03.00.00-0004
Bootloader Version = 06.253.57.219
Driver Name = megaraid_sas
Driver Version = 07.701.17.00-rh1
Bus :
===
Vendor Id = 0x1000
Device Id = 0x5B
SubVendor Id = 0x1028
SubDevice Id = 0x1F2D
Host Interface = PCI-E
Device Interface = SAS-6G
Bus Number = 4
Device Number = 0
Function Number = 0
Pending Images in Flash :
=======================
Image name = No pending images
Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = 0
PD Firmware Download in progress = No
Support PD Firmware Download = No
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No
Controller shutdown required = No
Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate = Yes
Reconstruction Rate = Yes
Patrol Read Rate = Yes
Alarm Control = Yes
Cluster Support = No
BBU = Yes
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = Yes
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = No
Snapshot Enabled = No
Support PFK = No
Support PI = No
Support Ld BBM Info = No
Support Shield State = No
Block SSD Write Disk Cache Change = No
Support Suspend Resume BG ops = No
Support Emergency Spares = No
Support Set Link Speed = No
Support Boot Time PFK Change = No
Support SystemPD = No
Disable Online PFK Change = No
Support Perf Tuning = Yes
Support SSD PatrolRead = No
Real Time Scheduler = No
Support Reset Now = No
Support Emulated Drives = No
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = No
Extended LD = No
Support Uneven span = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = No
Support Ext Enclosure = No
Support Sesmonitoring = No
Support SecurityonJBOD = No
Support ForceFlash = No
Support DisableImmediateIO = No
Support LargeIOSupport = No
Support DrvActivityLEDSetting = No
Support FlushWriteVerify = No
Support CPLDUpdate = No
Support ForceTo512e = No
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support Ctrl Info Extended = No
Support IButton less = No
Support AES Encryption Algorithm = No
Support Encrypted MFC = No
Support Snapdump = No
Support Force Personality Change = No
Support Dual Fw Image = No
Support PSOC Update = No
Support Secure Boot = No
Support Clear Snapdump = No
Support Debug Queue = No
Support Least Latency Mode = Yes
Support OnDemand Snapdump = No
Enterprise Key management :
=========================
Capability = Not Supported
Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = Yes
Set Power State For Cfg = No
Support T10 Power State = Yes
Support Temperature = Yes
NCQ = No
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No
Support SSD Wear Gauge = No
Supported VD Operations :
=======================
Read Policy = Yes
Write Policy = Yes
IO Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = Yes
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = Yes
Support Powersave Max With Cache = No
Support Breakmirror = Yes
Support SSC WriteBack = No
Support SSC Association = No
Support VD Hide = No
Support VD Cachebypass = No
Support VD discardCacheDuringLDDelete = No
Support VD Scsi Unmap = No
HwCfg :
=====
ChipRevision = D1
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Present
Alarm = Missing
Serial Debugger = Present
NVRAM Size = 32KB
Flash Size = 16MB
On Board Memory Size = 1024MB
CacheVault Flash Size = NA
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Present
Upgradable CPLD = Absent
Upgradable PSOC = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 883
ROC temperature(Degree Celsius) = 56
Ctrl temperature(Degree Celsius) = 56
Policies :
========
Policies Table :
==============
------------------------------------------------
Policy Current Default
------------------------------------------------
Predictive Fail Poll Interval 300 sec
Interrupt Throttle Active Count 16
Interrupt Throttle Completion 50 us
Rebuild Rate 30 % 30%
PR Rate 30 % 30%
BGI Rate 30 % 30%
Check Consistency Rate 30 % 30%
Reconstruction Rate 30 % 30%
Cache Flush Interval 4s
------------------------------------------------
Flush Time(Default) = 4s
Drive Coercion Mode = 128MB
Auto Rebuild = On
Battery Warning = On
ECC Bucket Size = 255
ECC Bucket Leak Rate (hrs) = 4
Restore Hot Spare on Insertion = Off
Expose Enclosure Devices = Off
Maintain PD Fail History = Off
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off
Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = Yes
Enable Web BIOS = No
Enable PreBoot CLI = No
Enable BIOS = Yes
Max Drives to Spinup at One Time = 4
Maximum number of direct attached drives to spin up in 1 min = 20
Delay Among Spinup Groups (sec) = 12
Allow Boot with Preserved Cache = Off
High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No
Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 64 KB
Write Policy = WB
Read Policy = Adaptive
Cache When BBU Bad = Off
Cached IO = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 128 MB
ZCR Config = Unknown
Max Chained Enclosures = 4
Direct PD Mapping = No
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = No
Maintain PD Fail History = No
Zero Based Enclosure Enumeration = Yes
Disable Puncturing = No
EnableLDBBM = Yes
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = No
Dirty LED Shows Drive Activity = No
EnableCrashDump = No
Disable Online Controller Reset = No
Treat Single span R1E as R10 = Yes
Power Saving option = Enabled
TTY Log In Flash = Yes
Auto Enhanced Import = No
BreakMirror RAID Support = single span R1
Disable Join Mirror = Yes
Enable Shield State = No
Time taken to detect CME = 60 sec
Capabilities :
============
Supported Drives = SAS, SATA
RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10(2 or more drives per span), RAID50, RAID60
Enable SystemPD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Not Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 128
Max VD per array = 16
Max Number of VDs = 64
Max Parallel Commands = 1008
Max SGE Count = 60
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 42
Max Configurable CacheCade Size(GB) = 512
Max Transportable DGs = 0
Enable Snapdump = No
Enable SCSI Unmap = Yes
FDE Drive Mix Support = No
Min Strip Size = 64 KB
Max Strip Size = 1.000 MB
Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = NA
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 04/28/2021, 09:00:00
Battery learn Reoccurrence = 2160 hrs
OEMID = Dell
Drive Groups = 1
TOPOLOGY :
========
----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
----------------------------------------------------------------------------
0 - - - - RAID6 Optl N 80.186 TB dflt N N dflt N N
0 0 - - - RAID6 Optl N 80.186 TB dflt N N dflt N N
0 0 0 12:2 0 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 1 12:5 1 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 2 12:4 2 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 3 12:3 3 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 4 12:8 4 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 5 12:7 5 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 6 12:6 6 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 7 12:9 7 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 8 12:1 8 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 9 12:10 10 DRIVE Onln N 8.909 TB dflt N N dflt - N
0 0 10 12:11 11 DRIVE Onln N 8.909 TB dflt N N dflt - N
----------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 1
VD LIST :
=======
-----------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
-----------------------------------------------------------------
0/0 RAID6 Optl RW Yes RWBD - OFF 80.186 TB data100
-----------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 12
PD LIST :
=======
----------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------
12:0 9 GHS - 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:1 8 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:2 0 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:3 3 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:4 2 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:5 1 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:6 6 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:7 5 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:8 4 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:9 7 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:10 10 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
12:11 11 Onln 0 8.909 TB SAS HDD N N 512B ST10000NM0256 U -
----------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=Unsupported|UGShld=UnConfigured shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|rbld=Rebuild
BBU_Info :
========
----------------------------------------------
Model State RetentionTime Temp Mode MfgDate
----------------------------------------------
BBU Optimal 0 hour(s) 29C - 0/00/00
----------------------------------------------
Generating detailed summary of the adapter, it may take a while to complete.
CLI Version = 007.1020.0000.0000 July 1, 2019
Operating system = Linux 3.10.0-693.el7.x86_64
Controller = 2
Status = Success
Description = None
Basics :
======
Controller = 2
Model = PERC H810 Adapter
Serial Number = 41L003J
Current Controller Date/Time = 04/26/2021, 17:48:55
Current System Date/time = 04/26/2021, 17:49:10
SAS Address = 5c81f660e9192c00
PCI Address = 00:06:00:00
Mfg Date = 01/27/14
Rework Date = 01/27/14
Revision No = A03
Version :
=======
Firmware Package Build = 21.3.5-0002
Firmware Version = 3.131.05-8148
Bios Version = 5.42.00.1_4.12.05.00_0x05290003
Ctrl-R Version = 4.04-0003
Preboot CLI Version = 05.00-03:#%00008
NVDATA Version = 2.1108.03-0097
Boot Block Version = 2.03.00.00-0004
Bootloader Version = 06.253.57.219
Driver Name = megaraid_sas
Driver Version = 07.701.17.00-rh1
Bus :
===
Vendor Id = 0x1000
Device Id = 0x5B
SubVendor Id = 0x1028
SubDevice Id = 0x1F2D
Host Interface = PCI-E
Device Interface = SAS-6G
Bus Number = 6
Device Number = 0
Function Number = 0
Pending Images in Flash :
=======================
Image name = No pending images
Status :
======
Controller Status = Optimal
Memory Correctable Errors = 0
Memory Uncorrectable Errors = 0
ECC Bucket Count = 0
Any Offline VD Cache Preserved = No
BBU Status = 0
PD Firmware Download in progress = No
Support PD Firmware Download = No
Lock Key Assigned = No
Failed to get lock key on bootup = No
Lock key has not been backed up = No
Bios was not detected during boot = No
Controller must be rebooted to complete security operation = No
A rollback operation is in progress = No
At least one PFK exists in NVRAM = No
SSC Policy is WB = No
Controller has booted into safe mode = No
Controller shutdown required = No
Supported Adapter Operations :
============================
Rebuild Rate = Yes
CC Rate = Yes
BGI Rate = Yes
Reconstruction Rate = Yes
Patrol Read Rate = Yes
Alarm Control = Yes
Cluster Support = No
BBU = Yes
Spanning = Yes
Dedicated Hot Spare = Yes
Revertible Hot Spares = Yes
Foreign Config Import = Yes
Self Diagnostic = Yes
Allow Mixed Redundancy on Array = No
Global Hot Spares = Yes
Deny SCSI Passthrough = No
Deny SMP Passthrough = No
Deny STP Passthrough = No
Support more than 8 Phys = Yes
FW and Event Time in GMT = No
Support Enhanced Foreign Import = Yes
Support Enclosure Enumeration = Yes
Support Allowed Operations = Yes
Abort CC on Error = Yes
Support Multipath = Yes
Support Odd & Even Drive count in RAID1E = No
Support Security = Yes
Support Config Page Model = Yes
Support the OCE without adding drives = Yes
Support EKM = No
Snapshot Enabled = No
Support PFK = No
Support PI = No
Support Ld BBM Info = No
Support Shield State = No
Block SSD Write Disk Cache Change = No
Support Suspend Resume BG ops = No
Support Emergency Spares = No
Support Set Link Speed = No
Support Boot Time PFK Change = No
Support SystemPD = No
Disable Online PFK Change = No
Support Perf Tuning = Yes
Support SSD PatrolRead = No
Real Time Scheduler = No
Support Reset Now = No
Support Emulated Drives = No
Headless Mode = Yes
Dedicated HotSpares Limited = No
Point In Time Progress = No
Extended LD = No
Support Uneven span = No
Support Config Auto Balance = No
Support Maintenance Mode = No
Support Diagnostic results = No
Support Ext Enclosure = No
Support Sesmonitoring = No
Support SecurityonJBOD = No
Support ForceFlash = No
Support DisableImmediateIO = No
Support LargeIOSupport = No
Support DrvActivityLEDSetting = No
Support FlushWriteVerify = No
Support CPLDUpdate = No
Support ForceTo512e = No
Support discardCacheDuringLDDelete = No
Support JBOD Write cache = No
Support Large QD Support = No
Support Ctrl Info Extended = No
Support IButton less = No
Support AES Encryption Algorithm = No
Support Encrypted MFC = No
Support Snapdump = No
Support Force Personality Change = No
Support Dual Fw Image = No
Support PSOC Update = No
Support Secure Boot = No
Support Clear Snapdump = No
Support Debug Queue = No
Support Least Latency Mode = Yes
Support OnDemand Snapdump = No
Enterprise Key management :
=========================
Capability = Not Supported
Supported PD Operations :
=======================
Force Online = Yes
Force Offline = Yes
Force Rebuild = Yes
Deny Force Failed = No
Deny Force Good/Bad = No
Deny Missing Replace = No
Deny Clear = No
Deny Locate = No
Support Power State = Yes
Set Power State For Cfg = No
Support T10 Power State = Yes
Support Temperature = Yes
NCQ = No
Support Max Rate SATA = No
Support Degraded Media = No
Support Parallel FW Update = No
Support Drive Crypto Erase = No
Support SSD Wear Gauge = No
Supported VD Operations :
=======================
Read Policy = Yes
Write Policy = Yes
IO Policy = Yes
Access Policy = Yes
Disk Cache Policy = Yes
Reconstruction = Yes
Deny Locate = No
Deny CC = No
Allow Ctrl Encryption = No
Enable LDBBM = Yes
Support FastPath = Yes
Performance Metrics = Yes
Power Savings = Yes
Support Powersave Max With Cache = No
Support Breakmirror = Yes
Support SSC WriteBack = No
Support SSC Association = No
Support VD Hide = No
Support VD Cachebypass = No
Support VD discardCacheDuringLDDelete = No
Support VD Scsi Unmap = No
HwCfg :
=====
ChipRevision = D1
BatteryFRU = N/A
Front End Port Count = 0
Backend Port Count = 8
BBU = Present
Alarm = Missing
Serial Debugger = Present
NVRAM Size = 32KB
Flash Size = 16MB
On Board Memory Size = 1024MB
CacheVault Flash Size = NA
TPM = Absent
Upgrade Key = Absent
On Board Expander = Absent
Temperature Sensor for ROC = Present
Temperature Sensor for Controller = Present
Upgradable CPLD = Absent
Upgradable PSOC = Absent
Current Size of CacheCade (GB) = 0
Current Size of FW Cache (MB) = 883
ROC temperature(Degree Celsius) = 56
Ctrl temperature(Degree Celsius) = 56
Policies :
========
Policies Table :
==============
------------------------------------------------
Policy Current Default
------------------------------------------------
Predictive Fail Poll Interval 300 sec
Interrupt Throttle Active Count 16
Interrupt Throttle Completion 50 us
Rebuild Rate 30 % 30%
PR Rate 30 % 30%
BGI Rate 30 % 30%
Check Consistency Rate 30 % 30%
Reconstruction Rate 30 % 30%
Cache Flush Interval 4s
------------------------------------------------
Flush Time(Default) = 4s
Drive Coercion Mode = 128MB
Auto Rebuild = On
Battery Warning = On
ECC Bucket Size = 255
ECC Bucket Leak Rate (hrs) = 4
Restore Hot Spare on Insertion = Off
Expose Enclosure Devices = Off
Maintain PD Fail History = Off
Reorder Host Requests = On
Auto detect BackPlane = SGPIO/i2c SEP
Load Balance Mode = Auto
Security Key Assigned = Off
Disable Online Controller Reset = Off
Use drive activity for locate = Off
Boot :
====
BIOS Enumerate VDs = 1
Stop BIOS on Error = On
Delay during POST = 0
Spin Down Mode = None
Enable Ctrl-R = Yes
Enable Web BIOS = No
Enable PreBoot CLI = No
Enable BIOS = Yes
Max Drives to Spinup at One Time = 4
Maximum number of direct attached drives to spin up in 1 min = 20
Delay Among Spinup Groups (sec) = 12
Allow Boot with Preserved Cache = Off
High Availability :
=================
Topology Type = None
Cluster Permitted = No
Cluster Active = No
Defaults :
========
Phy Polarity = 0
Phy PolaritySplit = 0
Strip Size = 64 KB
Write Policy = WB
Read Policy = Adaptive
Cache When BBU Bad = Off
Cached IO = Off
VD PowerSave Policy = Controller Defined
Default spin down time (mins) = 30
Coercion Mode = 128 MB
ZCR Config = Unknown
Max Chained Enclosures = 4
Direct PD Mapping = No
Restore Hot Spare on Insertion = No
Expose Enclosure Devices = No
Maintain PD Fail History = No
Zero Based Enclosure Enumeration = Yes
Disable Puncturing = No
EnableLDBBM = Yes
DisableHII = No
Un-Certified Hard Disk Drives = Allow
SMART Mode = Mode 6
Enable LED Header = No
LED Show Drive Activity = No
Dirty LED Shows Drive Activity = No
EnableCrashDump = No
Disable Online Controller Reset = No
Treat Single span R1E as R10 = Yes
Power Saving option = Enabled
TTY Log In Flash = Yes
Auto Enhanced Import = No
BreakMirror RAID Support = single span R1
Disable Join Mirror = Yes
Enable Shield State = No
Time taken to detect CME = 60 sec
Capabilities :
============
Supported Drives = SAS, SATA
RAID Level Supported = RAID0, RAID1, RAID5, RAID6, RAID00, RAID10(2 or more drives per span), RAID50, RAID60
Enable SystemPD = No
Mix in Enclosure = Allowed
Mix of SAS/SATA of HDD type in VD = Not Allowed
Mix of SAS/SATA of SSD type in VD = Not Allowed
Mix of SSD/HDD in VD = Not Allowed
SAS Disable = No
Max Arms Per VD = 32
Max Spans Per VD = 8
Max Arrays = 128
Max VD per array = 16
Max Number of VDs = 64
Max Parallel Commands = 1008
Max SGE Count = 60
Max Data Transfer Size = 8192 sectors
Max Strips PerIO = 42
Max Configurable CacheCade Size(GB) = 512
Max Transportable DGs = 0
Enable Snapdump = No
Enable SCSI Unmap = Yes
FDE Drive Mix Support = No
Min Strip Size = 64 KB
Max Strip Size = 1.000 MB
Scheduled Tasks :
===============
Consistency Check Reoccurrence = 168 hrs
Next Consistency check launch = NA
Patrol Read Reoccurrence = 168 hrs
Next Patrol Read launch = 04/28/2021, 09:00:00
Battery learn Reoccurrence = 2160 hrs
OEMID = Dell
Drive Groups = 4
TOPOLOGY :
========
----------------------------------------------------------------------------
DG Arr Row EID:Slot DID Type State BT Size PDC PI SED DS3 FSpace TR
----------------------------------------------------------------------------
0 - - - - RAID6 Optl N 32.743 TB dflt N N dflt N N
0 0 - - - RAID6 Optl N 32.743 TB dflt N N dflt N N
0 0 0 12:0 9 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 1 12:1 8 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 2 12:2 0 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 3 12:3 3 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 4 12:4 2 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 5 12:5 1 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 6 12:6 6 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 7 12:7 5 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 8 12:8 4 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 9 12:9 7 DRIVE Onln N 3.637 TB dflt N N dflt - N
0 0 10 12:10 10 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 - - - - RAID6 Optl N 32.743 TB dflt N N dflt N N
1 0 - - - RAID6 Optl N 32.743 TB dflt N N dflt N N
1 0 0 25:2 13 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 1 25:5 14 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 2 25:4 15 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 3 25:3 16 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 4 25:8 26 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 5 25:7 18 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 6 25:6 19 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 7 25:9 53 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 8 25:1 21 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 9 25:0 22 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 0 10 25:10 23 DRIVE Onln N 3.637 TB dflt N N dflt - N
1 - - 25:11 24 DRIVE DHS - 3.637 TB - - - - - N
2 - - - - RAID6 Optl N 49.117 TB dflt N N dflt N N
2 0 - - - RAID6 Optl N 49.117 TB dflt N N dflt N N
2 0 0 39:0 36 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 1 39:1 35 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 2 39:2 27 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 3 39:3 30 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 4 39:4 29 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 5 39:5 28 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 6 39:6 33 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 7 39:7 32 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 8 39:8 31 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 9 39:9 34 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 0 10 39:10 37 DRIVE Onln N 5.457 TB dflt N N dflt - N
2 - - 39:11 38 DRIVE DHS - 5.457 TB - - - - - N
3 - - - - RAID6 Optl N 49.117 TB dflt N N dflt N N
3 0 - - - RAID6 Optl N 49.117 TB dflt N N dflt N N
3 0 0 52:0 49 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 1 52:1 48 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 2 52:2 40 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 3 52:3 43 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 4 52:4 42 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 5 52:5 41 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 6 52:6 46 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 7 52:7 45 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 8 52:8 44 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 9 52:9 47 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 0 10 52:10 50 DRIVE Onln N 5.457 TB dflt N N dflt - N
3 - - 52:11 51 DRIVE DHS - 5.457 TB - - - - - N
----------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
TR=Transport Ready
Virtual Drives = 4
VD LIST :
=======
---------------------------------------------------------------
DG/VD TYPE State Access Consist Cache Cac sCC Size Name
---------------------------------------------------------------
0/0 RAID6 Optl RW Yes RWBD - OFF 32.743 TB DATA
1/1 RAID6 Optl RW Yes RWBD - OFF 32.743 TB DATA1
2/2 RAID6 Optl RW Yes RWBD - OFF 49.117 TB Data2
3/3 RAID6 Optl RW Yes RWBD - OFF 49.117 TB Data3
---------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|Dgrd=Degraded
Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|TRANS=TransportReady|B=Blocked|
Consist=Consistent|R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
FWB=Force WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
Check Consistency
Physical Drives = 48
PD LIST :
=======
----------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type
----------------------------------------------------------------------------
12:0 9 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:1 8 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:2 0 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:3 3 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:4 2 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:5 1 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:6 6 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:7 5 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:8 4 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:9 7 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:10 10 Onln 0 3.637 TB SAS HDD N N 512B MG03SCA400 U -
12:11 11 GHS - 3.637 TB SAS HDD N N 512B MG03SCA400 U -
25:0 22 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:1 21 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:2 13 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:3 16 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:4 15 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:5 14 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:6 19 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:7 18 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:8 26 Onln 1 3.637 TB SAS HDD N N 512B ST4000NM0023 U -
25:9 53 Onln 1 3.637 TB SAS HDD N N 512B ST4000NM0295 U -
25:10 23 Onln 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
25:11 24 DHS 1 3.637 TB SAS HDD N N 512B WD4001FYYG U -
39:0 36 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:1 35 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:2 27 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:3 30 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:4 29 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:5 28 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:6 33 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:7 32 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:8 31 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:9 34 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:10 37 Onln 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
39:11 38 DHS 2 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:0 49 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:1 48 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:2 40 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:3 43 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:4 42 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:5 41 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:6 46 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:7 45 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:8 44 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:9 47 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:10 50 Onln 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
52:11 51 DHS 3 5.457 TB SAS HDD N N 512B HUS726060AL5214 U -
----------------------------------------------------------------------------
EID=Enclosure Device ID|Slt=Slot No.|DID=Device ID|DG=DriveGroup
DHS=Dedicated Hot Spare|UGood=Unconfigured Good|GHS=Global Hotspare
UBad=Unconfigured Bad|Onln=Online|Offln=Offline|Intf=Interface
Med=Media Type|SED=Self Encryptive Drive|PI=Protection Info
SeSz=Sector Size|Sp=Spun|U=Up|D=Down|T=Transition|F=Foreign
UGUnsp=Unsupported|UGShld=UnConfigured shielded|HSPShld=Hotspare shielded
CFShld=Configured shielded|Cpybck=CopyBack|CBShld=Copyback Shielded
UBUnsp=UBad Unsupported|rbld=Rebuild
BBU_Info :
========
----------------------------------------------
Model State RetentionTime Temp Mode MfgDate
----------------------------------------------
BBU Optimal 0 hour(s) 29C - 0/00/00
----------------------------------------------
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment