HomeAssistant Modbus configuration for Pichler LG350 Ventilation Units (possible for LG450 too)
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
modbus: | |
- name: pichlerlg350 | |
type: tcp | |
host: 192.168.44.232 | |
port: 502 | |
delay: 2 | |
message_wait_milliseconds: 30 | |
binary_sensors: | |
- name: "lg350_bypassklappe" # 0.0 | |
unique_id: "lg350_bypassklappe" | |
slave: 20 | |
address: 20 | |
input_type: input | |
device_class: opening | |
switches: | |
- name: "lg350_betriebsmodus_sommer" | |
slave: 20 | |
address: 1 | |
write_type: holding | |
command_on: 1 # Sommer | |
command_off: 2 # Winter | |
verify: | |
delay: 1 | |
- name: "lg350_bypassklappe_force_open" | |
slave: 20 | |
address: 49 | |
write_type: holding | |
# data_type: uint16 | |
command_on: 2 # Ein/Offen | |
command_off: 0 # Normal. "1" waere Aus/Geschlossen | |
verify: | |
delay: 1 | |
sensors: | |
- name: "lg350_temp_aussenluft" # 0.0 | |
unique_id: "lg350_temp_aussenluft" | |
unit_of_measurement: "°C" | |
slave: 20 | |
address: 30 | |
input_type: input | |
data_type: int16 | |
offset: -100 | |
precision: 1 | |
scale: 0.1 | |
- name: "lg350_temp_fortluft" # 3.0 | |
unique_id: "lg350_temp_fortluft" | |
unit_of_measurement: "°C" | |
slave: 20 | |
address: 31 # 30 | |
input_type: input | |
data_type: int16 | |
offset: -100 | |
precision: 1 | |
scale: 0.1 | |
- name: "lg350_temp_abluft" # 0.2 | |
unique_id: "lg350_temp_abluft" | |
unit_of_measurement: "°C" | |
slave: 20 | |
address: 32 # 31 | |
input_type: input | |
data_type: int16 | |
offset: -100 | |
precision: 1 | |
scale: 0.1 | |
- name: "lg350_temp_zuluft" # xxx | |
unique_id: "lg350_temp_zuluft" | |
unit_of_measurement: "°C" | |
slave: 20 | |
address: 33 # 32 | |
input_type: input | |
data_type: int16 | |
offset: -100 | |
precision: 1 | |
scale: 0.1 | |
- name: "lg350_temp_aussenluft_vhr" | |
unique_id: "lg350_temp_aussenluft_vhr" | |
unit_of_measurement: "°C" | |
slave: 20 | |
address: 34 | |
input_type: input | |
data_type: int16 | |
offset: -100 | |
precision: 1 | |
scale: 0.1 | |
- name: "lg350_zuluftdrehzahl" | |
unique_id: "lg350_zuluftdrehzahl" | |
unit_of_measurement: "rpm" | |
slave: 20 | |
address: 39 | |
input_type: input | |
data_type: int16 | |
- name: "lg350_abluftdrehzahl" | |
unique_id: "lg350_abluftdrehzahl" | |
unit_of_measurement: "rpm" | |
slave: 20 | |
address: 40 | |
input_type: input | |
data_type: int16 | |
- name: "lg350_zuluftstrom" | |
unique_id: "lg350_zuluftstrom" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 46 | |
input_type: input | |
data_type: int16 | |
- name: "lg350_abluftstrom" | |
unique_id: "lg350_abluftstrom" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 47 | |
input_type: input | |
data_type: int16 | |
- name: "lg350_reststandzeit_filter" | |
unique_id: "lg350_reststandzeit_filter" | |
unit_of_measurement: "h" | |
slave: 20 | |
address: 50 | |
input_type: input | |
data_type: uint16 | |
- name: "lg350_betriebsmodus_sw" | |
unique_id: "lg350_betriebsmodus_sw" | |
slave: 20 | |
address: 1 | |
input_type: holding | |
data_type: uint16 | |
- name: "lg350_lufstrom_stufe1" | |
unique_id: "lg350_luftstrom_stufe1" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 9 | |
input_type: holding | |
data_type: int16 | |
- name: "lg350_lufstrom_stufe2" | |
unique_id: "lg350_luftstrom_stufe2" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 10 | |
input_type: holding | |
data_type: int16 | |
- name: "lg350_lufstrom_stufe3" | |
unique_id: "lg350_luftstrom_stufe3" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 11 | |
input_type: holding | |
data_type: int16 | |
- name: "lg350_luftstufe" | |
unique_id: "lg350_luftstufe" | |
slave: 20 | |
address: 2 | |
input_type: holding | |
data_type: int16 | |
- name: "lg350_bypassklappe_set" | |
unique_id: "lg350_bypassklappe_set" | |
slave: 20 | |
address: 49 | |
input_type: holding | |
data_type: int16 | |
- name: "lg350_abluftdifferenz_stufe1" | |
unique_id: "lg350_abluftdifferenz_stufe1" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 83 | |
input_type: holding | |
data_type: int16 | |
offset: -500 | |
- name: "lg350_abluftdifferenz_stufe2" | |
unique_id: "lg350_abluftdifferenz_stufe2" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 84 | |
input_type: holding | |
data_type: int16 | |
offset: -500 | |
- name: "lg350_abluftdifferenz_stufe3" | |
unique_id: "lg350_abluftdifferenz_stufe3" | |
unit_of_measurement: "m3/h" | |
slave: 20 | |
address: 85 | |
input_type: holding | |
data_type: int16 | |
offset: -500 | |
sensor: | |
- platform: template | |
sensors: | |
lg350_luftstufe_render: | |
friendly_name: "Luftstufe" | |
value_template: >- | |
{% set lg350_luftstufe_mapper = { | |
0: 'Standby', | |
1: 'Stufe 1', | |
2: 'Stufe 2', | |
3: 'Stufe 3', | |
4: 'Grundlüftung'} %} | |
{% set state = states('sensor.lg350_luftstufe')|int %} | |
{{ lg350_luftstufe_mapper[state] if state in lg350_luftstufe_mapper else 'Unknown' }} | |
lg350_bypassklappe_set_render: | |
friendly_name: "Bypass Klappe Stellung" | |
value_template: >- | |
{% set lg350_bypassklappe_set_mapper = { | |
0: 'Normal', | |
1: 'Aus/Geschlossen', | |
2: 'Ein/Offen'} %} | |
{% set state = states('sensor.lg350_bypassklappe_set')|int %} | |
{{ lg350_bypassklappe_set_mapper[state] if state in lg350_bypassklappe_set_mapper else 'Unknown' }} | |
lg350_betriebsmodus_sw_render: | |
friendly_name: "Betriebsmodus" | |
value_template: >- | |
{% set lg350_betriebsmodus_sw_mapper = { | |
1: 'Sommer', | |
2: 'Winter'} %} | |
{% set state = states('sensor.lg350_betriebsmodus_sw')|int %} | |
{{ lg350_betriebsmodus_sw_mapper[state] if state in lg350_betriebsmodus_sw_mapper else 'Unknown' }} | |
template: | |
- sensor: | |
- name: "LG350 Heizleistung" | |
unique_id: "lg350_heizleistung" | |
state_class: "measurement" | |
unit_of_measurement: "W" | |
device_class: power | |
state: > | |
{% set vorlauf = states('sensor.lg350_temp_zuluft') | float (0) %} | |
{% set ruecklauf = states('sensor.lg350_temp_abluft') | float %} | |
{% set durchfluss = states('sensor.lg350_zuluftstrom') | float %} | |
{{ ((vorlauf - ruecklauf) * durchfluss * 0.33 ) | round(1, default=0) }} |
Hello guys,
excuse me if it is a dumb question, First time doing something with Modbus RTU-> TCP and not too long in HA
Has anyone an idea why i can´t set any settings at the ventilation unit?
I have the same device Elfin EE11A as [mihu-ov].
Can´t seem to find the right setting for this
Elfin seems to communicate with the HA instance
Thanks
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Thank you! As mentioned in the forum, I've received some (incomplete) documentation from Pichler for the LG 150 and updated my config here: https://gist.github.com/sventiffe/788b25ff50a8b3cc2c3a33cac5576616
I've defined an input number and action like suggested:
In contrast, apparently, to the bigger devices, the LG150 operates with 1/10th of the actual settings. I've also defined helper methods to render the air volume nicely, multiplying the modbus data by 10