Save patrickdk77/b687448fecff68d8572ac79a27d07862 to your computer and use it in GitHub Desktop.
Template | |
{"NAME":"Tuya Siren","GPIO":[255,107,255,108,255,255,0,0,255,255,255,255,255],"FLAG":0,"BASE":54} | |
You must activate the template before using any of the tuya commands below. | |
Recommended rules for tasmota: | |
rule1 on system#boot backlog tuyasend4 102,0; tuyasend2 103,300; TuyaSend1 117,0 endon | |
rule1 1 | |
tuyamcu 11,104 | |
This will set the default alarm length (5min), music (0), volume (0 high), and assign relay1 (power1) to the alarm activation. | |
The alarm length and music doesn't appear to be retained during power cycles. | |
0x65 Power State 101 | |
55 aa 03 07 00 05 65 04 00 01 04 7c (on usb power) | |
55 aa 03 07 00 05 65 04 00 01 00 78 (on battery power, 0=full battery maybe (1/2/3 battery level?) | |
x66 Change Alarm sound | |
TuyaSend4 102,0 (0 to 11 on mine, other upto 17) | |
x67 Change Alarm seconds | |
TuyaSend2 103,10 (1 to 60 on mine, 1800 on another) | |
x68 Alarm sounding | |
TuyaSend4 104,0 (off) | |
TuyaSend4 104,1 (on) | |
55 aa 03 07 00 05 68 01 00 01 01 79 | |
55 aa 03 07 00 05 71 01 00 01 00 81 | |
x69 tempature reporting (105) | |
55 aa 03 07 00 08 69 02 00 04 00 00 00 c3 43 (tempature in C*10) | |
x6a humidity reporting (106) | |
55 aa 03 07 00 08 6a 02 00 04 00 00 00 3b bc (59%) | |
x6b temp alarm low in C | |
TuyaSend4 107,17 | |
55 aa 00 06 00 08 6b 02 00 04 00 00 00 11 8f | |
x6c temp alarm high in C | |
TuyaSend4 108,38 | |
55 aa 00 06 00 08 6c 02 00 04 00 00 00 26 a5 | |
x6d set humidity alarm low | |
TuyaSend4 109,40 | |
55 aa 00 06 00 08 6d 02 00 04 00 00 00 46 c6 low in percent | |
x6e set humidity alarm high | |
TuyaSend4 110,80 | |
55 aa 00 06 00 08 6e 02 00 04 00 00 00 50 d1 high in percent | |
x6f | |
x70 Change to C and F units | |
TuyaSend1 112,1 (on) | |
55 aa 00 06 00 05 70 01 00 01 01 7d (C) | |
55 aa 00 06 00 05 70 01 00 01 00 7c (F) | |
x71 alarm temp on and off | |
TuyaSend1 113,1 (on) | |
55 aa 00 06 00 05 71 01 00 01 01 7e (on) | |
55 aa 00 06 00 05 71 01 00 01 00 7d (off) | |
x72 humidity alarm on/off | |
TuyaSend1 114,1 (on) | |
55 aa 00 06 00 05 72 01 00 01 01 7f (on) | |
55 aa 00 06 00 05 72 01 00 01 00 7e (off) | |
x73 alarm temp/humidity triggered | |
0=high tempature | |
1=high humidity | |
2=low tempature | |
3=low humidity | |
4=? | |
5=all normal | |
55 aa 03 07 00 05 73 04 00 01 02 88 (2 tempature alarm) | |
55 aa 03 07 00 05 73 04 00 01 03 89 (3 humidity alarm) | |
55 aa 03 07 00 05 73 04 00 01 05 8b (5 all clear) | |
x74 Alarm db setting (loudness) | |
TuyaSend1 117,0 (high) | |
55 aa 00 06 00 05 74 04 00 01 02 85 Low | |
55 aa 00 06 00 05 74 04 00 01 01 84 secondary | |
55 aa 00 06 00 05 74 04 00 01 00 83 High | |
Hi @patrickdk77
I just got a NEDIS siren, and converted it, and tried out your template, it almost works!
This is great work, thanks!
My only problem is that it looses the selected alarm sound after a reboot.
I've changed the rule to:
rule1 on system#boot backlog tuyasend4 102,11; tuyasend2 103,300; TuyaSend1 117,0 endon
But it still uses alarm sound 0 (which is a doorbell).
I have no idea what you are doing, but it's great :-D
I wonder if it can be converted to ESPHome somehow...
It can be, just use the esphome tuya module.
I never published any more details on exactly how to set these up with exact instructions cause I killed two of them in the process of making this and didn't bother to buy a 3rd one. So I don't have a way currently to verify my instructions would work if I made them.
These things do not support rechargeable lithium batteries. using 4.2volts fries these things, so you have to stick to the 3.0v batteries.
I assume this is due to the voltage regulator cannot handle 8.4v, but only supports 6v.
Hey @patrickdk77
Tell me about it, burning items because you want to tinker :-D
When you write eg. "55 aa 03 07 00 05 68 01 00 01 01 79" is that the codes sent via the UART?
Yes !
You're right !!!
After setting up the MQTT broker, the TuyaSend commands are working.
Good news !