| modbus: | |
| - name: pichlerlg350 | |
| type: tcp | |
| host: 192.168.44.232 | |
| port: 502 | |
| delay: 2 | |
| message_wait_milliseconds: 30 | |
| binary_sensors: | |
| - name: "lg350_bypassklappe" # 0.0 | |
| unique_id: "lg350_bypassklappe" | |
| slave: 20 | |
| address: 20 | |
| input_type: input | |
| device_class: opening | |
| switches: | |
| - name: "lg350_betriebsmodus_sommer" | |
| slave: 20 | |
| address: 1 | |
| write_type: holding | |
| command_on: 1 # Sommer | |
| command_off: 2 # Winter | |
| verify: | |
| delay: 1 | |
| - name: "lg350_bypassklappe_force_open" | |
| slave: 20 | |
| address: 49 | |
| write_type: holding | |
| # data_type: uint16 | |
| command_on: 2 # Ein/Offen | |
| command_off: 0 # Normal. "1" waere Aus/Geschlossen | |
| verify: | |
| delay: 1 | |
| sensors: | |
| - name: "lg350_temp_aussenluft" # 0.0 | |
| unique_id: "lg350_temp_aussenluft" | |
| unit_of_measurement: "°C" | |
| slave: 20 | |
| address: 30 | |
| input_type: input | |
| data_type: int16 | |
| offset: -100 | |
| precision: 1 | |
| scale: 0.1 | |
| - name: "lg350_temp_fortluft" # 3.0 | |
| unique_id: "lg350_temp_fortluft" | |
| unit_of_measurement: "°C" | |
| slave: 20 | |
| address: 31 # 30 | |
| input_type: input | |
| data_type: int16 | |
| offset: -100 | |
| precision: 1 | |
| scale: 0.1 | |
| - name: "lg350_temp_abluft" # 0.2 | |
| unique_id: "lg350_temp_abluft" | |
| unit_of_measurement: "°C" | |
| slave: 20 | |
| address: 32 # 31 | |
| input_type: input | |
| data_type: int16 | |
| offset: -100 | |
| precision: 1 | |
| scale: 0.1 | |
| - name: "lg350_temp_zuluft" # xxx | |
| unique_id: "lg350_temp_zuluft" | |
| unit_of_measurement: "°C" | |
| slave: 20 | |
| address: 33 # 32 | |
| input_type: input | |
| data_type: int16 | |
| offset: -100 | |
| precision: 1 | |
| scale: 0.1 | |
| - name: "lg350_temp_aussenluft_vhr" | |
| unique_id: "lg350_temp_aussenluft_vhr" | |
| unit_of_measurement: "°C" | |
| slave: 20 | |
| address: 34 | |
| input_type: input | |
| data_type: int16 | |
| offset: -100 | |
| precision: 1 | |
| scale: 0.1 | |
| - name: "lg350_zuluftdrehzahl" | |
| unique_id: "lg350_zuluftdrehzahl" | |
| unit_of_measurement: "rpm" | |
| slave: 20 | |
| address: 39 | |
| input_type: input | |
| data_type: int16 | |
| - name: "lg350_abluftdrehzahl" | |
| unique_id: "lg350_abluftdrehzahl" | |
| unit_of_measurement: "rpm" | |
| slave: 20 | |
| address: 40 | |
| input_type: input | |
| data_type: int16 | |
| - name: "lg350_zuluftstrom" | |
| unique_id: "lg350_zuluftstrom" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 46 | |
| input_type: input | |
| data_type: int16 | |
| - name: "lg350_abluftstrom" | |
| unique_id: "lg350_abluftstrom" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 47 | |
| input_type: input | |
| data_type: int16 | |
| - name: "lg350_reststandzeit_filter" | |
| unique_id: "lg350_reststandzeit_filter" | |
| unit_of_measurement: "h" | |
| slave: 20 | |
| address: 50 | |
| input_type: input | |
| data_type: uint16 | |
| - name: "lg350_betriebsmodus_sw" | |
| unique_id: "lg350_betriebsmodus_sw" | |
| slave: 20 | |
| address: 1 | |
| input_type: holding | |
| data_type: uint16 | |
| - name: "lg350_lufstrom_stufe1" | |
| unique_id: "lg350_luftstrom_stufe1" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 9 | |
| input_type: holding | |
| data_type: int16 | |
| - name: "lg350_lufstrom_stufe2" | |
| unique_id: "lg350_luftstrom_stufe2" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 10 | |
| input_type: holding | |
| data_type: int16 | |
| - name: "lg350_lufstrom_stufe3" | |
| unique_id: "lg350_luftstrom_stufe3" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 11 | |
| input_type: holding | |
| data_type: int16 | |
| - name: "lg350_luftstufe" | |
| unique_id: "lg350_luftstufe" | |
| slave: 20 | |
| address: 2 | |
| input_type: holding | |
| data_type: int16 | |
| - name: "lg350_bypassklappe_set" | |
| unique_id: "lg350_bypassklappe_set" | |
| slave: 20 | |
| address: 49 | |
| input_type: holding | |
| data_type: int16 | |
| - name: "lg350_abluftdifferenz_stufe1" | |
| unique_id: "lg350_abluftdifferenz_stufe1" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 83 | |
| input_type: holding | |
| data_type: int16 | |
| offset: -500 | |
| - name: "lg350_abluftdifferenz_stufe2" | |
| unique_id: "lg350_abluftdifferenz_stufe2" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 84 | |
| input_type: holding | |
| data_type: int16 | |
| offset: -500 | |
| - name: "lg350_abluftdifferenz_stufe3" | |
| unique_id: "lg350_abluftdifferenz_stufe3" | |
| unit_of_measurement: "m3/h" | |
| slave: 20 | |
| address: 85 | |
| input_type: holding | |
| data_type: int16 | |
| offset: -500 | |
| sensor: | |
| - platform: template | |
| sensors: | |
| lg350_luftstufe_render: | |
| friendly_name: "Luftstufe" | |
| value_template: >- | |
| {% set lg350_luftstufe_mapper = { | |
| 0: 'Standby', | |
| 1: 'Stufe 1', | |
| 2: 'Stufe 2', | |
| 3: 'Stufe 3', | |
| 4: 'Grundlüftung'} %} | |
| {% set state = states('sensor.lg350_luftstufe')|int %} | |
| {{ lg350_luftstufe_mapper[state] if state in lg350_luftstufe_mapper else 'Unknown' }} | |
| lg350_bypassklappe_set_render: | |
| friendly_name: "Bypass Klappe Stellung" | |
| value_template: >- | |
| {% set lg350_bypassklappe_set_mapper = { | |
| 0: 'Normal', | |
| 1: 'Aus/Geschlossen', | |
| 2: 'Ein/Offen'} %} | |
| {% set state = states('sensor.lg350_bypassklappe_set')|int %} | |
| {{ lg350_bypassklappe_set_mapper[state] if state in lg350_bypassklappe_set_mapper else 'Unknown' }} | |
| lg350_betriebsmodus_sw_render: | |
| friendly_name: "Betriebsmodus" | |
| value_template: >- | |
| {% set lg350_betriebsmodus_sw_mapper = { | |
| 1: 'Sommer', | |
| 2: 'Winter'} %} | |
| {% set state = states('sensor.lg350_betriebsmodus_sw')|int %} | |
| {{ lg350_betriebsmodus_sw_mapper[state] if state in lg350_betriebsmodus_sw_mapper else 'Unknown' }} | |
| template: | |
| - sensor: | |
| - name: "LG350 Heizleistung" | |
| unique_id: "lg350_heizleistung" | |
| state_class: "measurement" | |
| unit_of_measurement: "W" | |
| device_class: power | |
| state: > | |
| {% set vorlauf = states('sensor.lg350_temp_zuluft') | float (0) %} | |
| {% set ruecklauf = states('sensor.lg350_temp_abluft') | float %} | |
| {% set durchfluss = states('sensor.lg350_zuluftstrom') | float %} | |
| {{ ((vorlauf - ruecklauf) * durchfluss * 0.33 ) | round(1, default=0) }} |
I answered (mostly) in the energiesparhaus thread.
set the ventilation volume for one specific level or
I configured an input_number for that in Home Assistant (Settings -> Devices & services -> Helpers), so that I have a nice UI slider.
and then there is an automation associated with it:
alias: "lg350: base change "
description: ""
mode: single
triggers:
- entity_id:
- input_number.lg350_base_luftmenge
from: null
to: null
trigger: state
conditions: []
actions:
- data_template:
hub: pichlerlg350
address: 9
slave: 20
value: "{{ states('input_number.lg350_base_luftmenge') | int }}"
action: modbus.write_registerYou could do something similar for the ventilation level. Personally I just stick to one ventilation level and adapt the volume of that. For example, I've a CO2 sensor in my bedroom and control the ventilation level based on the CO2 concentration; that automation just changes input_number.lg350_base_luftmenge which will trigger the automation above to propagate the value to the correct modbus register.
Thank you! As mentioned in the forum, I've received some (incomplete) documentation from Pichler for the LG 150 and updated my config here: https://gist.github.com/sventiffe/788b25ff50a8b3cc2c3a33cac5576616
I've defined an input number and action like suggested:
alias: 'lg150: luftmenge stufe 1 änderung'
description: ''
triggers:
- entity_id:
- input_number.lg150_base_luftmenge
from: null
to: null
trigger: state
conditions: []
actions:
- data_template:
hub: pichler_lg150
address: 9
slave: 20
value: '{{ states(''input_number.lg150_base_luftmenge'') | int / 10 }}'
action: modbus.write_register
mode: single
In contrast, apparently, to the bigger devices, the LG150 operates with 1/10th of the actual settings. I've also defined helper methods to render the air volume nicely, multiplying the modbus data by 10
Hello guys,
excuse me if it is a dumb question, First time doing something with Modbus RTU-> TCP and not too long in HA
Has anyone an idea why i can´t set any settings at the ventilation unit?
I have the same device Elfin EE11A as [mihu-ov].
Can´t seem to find the right setting for this
Elfin seems to communicate with the HA instance
Thanks
I'd like to add more sensors to my configuration. I do have a LG 150 but so far the configuration for 450 seems to work. There are some inconsistencies though (for example, the status of the bypass is "bypass" according to the touch panel, but "off" according to the modus signal). I have two newbie questions that you might be able to answer:
So i've added a bunch of sensors and will test the configuration with my LG 150. I still do not understand the discrepancy between the bypass signals on the touch display and in home assistant though. The other values seem to be reasonable.
Can anyone help me with understanding how to either
The latter would allow to manually control or to automate the ventilation control from home assistant.
Edit again, answering my question with https://www.energiesparhaus.at/forum-erfahrungsaustausch-pichlerluft-kompaktlueftungsgeraete-lg-350-lg-450/75919_6#831043